The formaldehyde (HCHO) and volatile organic compound (VOCs) pollution characteristics of the residential kitchen in severe cold regions of northeast China were investigated by on-site measurement, questionnaire and correlation analysis. A total of 33 residential kitchens in three cities were selected as samples. Gas chromatography–mass spectrometry, phenol reagent spectrophotometer and 2,4-dinitrophenylhydrazine were applied. The change of VOC concentration during cooking was tracked by parts per billion ppb RAE detector. Moreover, the CO2 tracer gas method was used to measure air changes when the range hood was open under different window-opening angles. The results demonstrate that though the excess rate of HCHO in the kitchen was only 5.3% before cooking, the average VOC concentration (1.269 mg/m3) exceeded far beyond the standard and was obviously higher than other climate zones. During cooking, the VOC concentration was in a state of seriously exceeding standard. The average concentration of aldehyde and ketone pollutants during cooking was 0.431 mg/m3. Frying produced more VOCs than stewing. The influence factors of HCHO and VOC pollution characteristics were explored. Increasing make-up air and optimizing cooking habits are significant in alleviating kitchen pollution in northeast China.
The transformation of family structure in China has resulted in a surge in the demand for elderly care, as seniors are always frail and unable to tend to their own needs. Consequently, it is imperative that nursing homes provide a secure indoor environment. To this end, sophisticated instruments or national standard methods had been employed to measure indoor environmental parameters, while objective questionnaire interviews targeting the elderly had been conducted during the winter of 2021. The findings revealed a temperature differential of 3.5°C between north- and south-facing rooms. An average indoor concentration of formaldehyde (HCHO) of 0.025 mg/m 3 with PM 2.5 and CO 2 concentrations remaining within acceptable limits. Furthermore, senior citizens expressed greater concern regarding indoor temperature, humidity levels, sunlight exposure and ventilation quality. Based on the research findings, computational fluid dynamics tools were employed to simulate and optimize ventilation in an existing nursing home. Natural ventilation and simple mechanical ventilation were proposed as practical approaches to fulfil the health and comfort requirements of elderly residents. The outcomes offer programmatic and data support for comprehending indoor environments in nursing homes located in severely cold regions, as well as for retrofitting indoor ventilation systems in economically viable existing nursing facilities.
In order to solve the problem of input fresh air overheating (cooling) in the cold supply (heating) season in severe cold regions, a soil source (BHE) combined with fresh air preheating (cooling) air conditioning system was studied in a net-zero energy building in Shenyang. Firstly, a hybrid TRNSYS-CFD simulation model based on TRNSYS and Fluent simulation software was established to simulate the operation and indoor temperature distribution of the air conditioning system in the building during a typical day in the summer (winter) season. The TRNSYS-CFD hybrid simulation allows simultaneous analysis of the operating characteristics of the air conditioning system and the real-time indoor temperature distribution. The results show that the accuracy of the hybrid simulation is compared with that of the TRNSYS stand-alone simulation by monitoring the temperature changes in each room. The room temperature from the TRNSYS stand-alone simulation is the average temperature of the room return air, while the room temperature from the hybrid simulation has a stratification effect and the simulation data is more valuable for reference.