26 January 2025 in Journal of Dentistry
The study aimed to evaluate the accuracy and safety of a semi-active robotic system for implant placement in atrophic posterior maxilla. Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery. The virtual implant position and drilling sequences were planned in the robotic planning system. Patients with positioning marker took an intraoral scan. The preoperative CBCT and the intraoral scan were superimposed in the robotic software. After registration, the implant bed was prepared utilizing the robotic arm with 1 mm safety margin below the maxillary sinus floor. The transcrestal sinus floor elevation (TSFE) was performed by the dentist, followed by the implant placement with the robotic arm. A postoperative CBCT was taken and superimposed with the preoperative one to calculate the accuracy of implant placement. Complications and adverse events were recorded. Deviations between the implant platform and apex levels were analyzed using the paired t-test. P < 0.05 was considered statistically significant. Twenty-seven implants of 20 patients were included. No intraoperative and postoperative complications were reported. The global, lateral and vertical platform deviations were 0.73 ± 0.27 mm, 0.35 ± 0.23 mm and 0.35 ± 0.57 mm, respectively. The global, lateral and vertical apex deviations were 0.77 ± 0.23 mm, 0.41 ± 0.20 mm and 0.34 ± 0.57 mm, respectively. There were significant differences between the global, lateral and vertical deviations between the implant platform and apex levels (P < 0.05, respectively). The angular deviation was 1.58 ± 0.76°. High accuracy and safety for implant placement in atrophic posterior maxilla could be achieved using a semi-active robotic system, with the TSFE procedure performed by the dentist. This study provides significant evidence to support the application of semi-active robotic systems for implant placement in atrophic posterior maxilla.
24 January 2026 in Journal of Dentistry
This study aimed to assess the accuracy of implant placement performed using robotic computer-assisted implant surgery (r-CAIS) by comparing postoperative measurements obtained via intraoral scanning (IOS) with those derived from cone-beam computed tomography (CBCT). The study employed a cross-sectional design. All patients received a preoperative CBCT and IOS for surgical planning and registration. All the surgeries were performed using r-CAIS. Postoperative CBCT and IOS datasets were acquired for each patient and superimposed on the preoperative datasets to assess deviations between planned and actual implant positions. Paired t-tests were used to analyze differences between the two assessment modalities, with statistical significance defined as P < 0.05. Agreement between the two methods was evaluated using intra-class correlation coefficients (ICCs) and Bland-Altman analyses. Thirty-four implants in twenty-seven patients were included. Global coronal, global apical, and angular deviations measured using the IOS method were 0.59 ± 0.23 mm, 0.66 ± 0.24 mm, and 1.28 ± 0.69°, respectively, compared with 0.59 ± 0.24 mm, 0.63 ± 0.25 mm, and 1.19 ± 0.70° measured by the CBCT method. No statistically significant differences were observed between the two modalities (P > 0.05, respectively). ICCs for global coronal, global apical, and angular deviations were 0.911, 0.886, and 0.856, respectively. Bland-Altman analyses further confirmed excellent agreement between the two methods. Both IOS and CBCT methods demonstrated comparable accuracy and good agreement in r-CAIS. Postoperative IOS method may serve as a reliable and radiation-free alternative to CBCT for assessing implant placement accuracy in r-CAIS in patients with a single missing tooth or two consecutive missing teeth. In future, multicenter randomized controlled trials with larger sample sizes are warranted to further validate these findings.
13 April 2026 in Journal of Dentistry
This retrospective study aimed to evaluate the impact of artificial intelligence (AI)-based automated segmentation (AS) on the accuracy of robotic computer-aided implant surgery (r-CAIS). Patients who underwent r-CAIS were enrolled. Preoperative CBCT images were segmented using either threshold-based SS approach (SS group) or the AI-based AS approach (AS group). Osteotomy preparation and implant placement were performed using a semi-active robot. Registration errors and deviations between planned and postoperatively placed implant positions were calculated. Intergroup comparisons were performed using Wilcoxon Mann-Whitney U tests, with P < 0.05 considered significant. A total of 140 patients (79 females, 61 males) receiving 224 implants were included (SS group: 69 patients, 107 implants; AS group: 71 patients, 117 implants). The registration error in the AS group (0.10 ± 0.04 mm) was significantly lower than that in the SS group (0.12 ± 0.04 mm) (P < 0.05). The AS group demonstrated lower deviations at the platform (0.51 ± 0.16 vs.0.56 ± 0.18 mm), apex (0.60 ± 0.23 vs. 0.66 ± 0.23 mm), and angulation (1.13 ± 0.59° vs. 1.19 ± 0.53°), with a statistically significant difference observed in global platform deviation (P < 0.05). r-CAIS demonstrated consistently high accuracy, which was further improved by AI-based AS. This improvement may be associated with enhanced registration precision achieved through AI-based AS. These findings support the potential clinical application of AI-based AS in r-CAIS.