Yuhang Shi

Yuhang Shi

Auto-generated profile, based on publicly available information

Yuhang Shi

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, 12480 Xi'an, Shaanxi China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YSYuhang Shi
Yuhang Shi
SJShengchang Ji
Shengchang Ji
FZFan Zhang
Fan Zhang
FRFuqiang Ren
Fuqiang Ren
JLJinyu Li
Jinyu Li
LZLingyu Zhu
Lingyu Zhu
The large current flowing through transformer windings during external short-circuit event causes strong vibration and the tank emits multi-frequency sound. This paper investigates the transient acoustic signal theoretically and experimentally, and proposes to monitor the winding condition with the spectrum of the acoustic signal. A two-wire model is first built as a basic unit of winding structure. The dynamic equation of the model is constructed based on principle of least action. The solution shows that the spectrum of the winding vibration contains half power frequency and its multiples in some cases. If the winding is loosened and deformed, the motion space and vibration amplitude would be enlarged and the natural frequency of winding would decrease. As a result, the vibration spectrum would contain half frequency and its odd multiples. Then the acoustic signal of a 110 kV transformer is measured on a short-circuit test platform. The acoustic time-frequency spectrums are consistent with the theoretical analysis. The half frequency ratio (HFR) of the acoustic signal is proposed to characterize the winding condition. The results prove that HFR of acoustic signal is a more sensitive indicator than the short-circuit reactance, which can characterize the cumulative process of short-circuit on the winding.

1 September 2018
Verified
Conference Paper
Closed access
CZCao Zhan
Cao Zhan
SJShengchang Ji
Shengchang Ji
YLYong Liu
Yong Liu
LZLingyu Zhu
Lingyu Zhu
YSYuhang Shi
Yuhang Shi
FRFuqiang Ren
Fuqiang Ren
Huge electromagnetic force during sudden short circuit can cause severe winding mechanical fault. Transformer tank vibration characteristics are closely related to winding mechanical condition. Transient vibration response on transformer tank under short circuit impact can be utilized to monitor winding condition and diagnose winding fault. Short circuit impact experiment according to IEC standard is performed on a 110kV transformer. 33 times impacts were performed at A-phase and tank vibration signal is recorded every time during the impact. Since transformer transient vibration signal is non-linear and non-stationary, this paper utilizes Hilbert-Huang Transform (HHT) methodology to analyze transformer vibration signal in time-frequency domain. 200Hz-1000Hz component in Hilbert spectrum is deeply studied. Image processing method is used to quantity the occurrence number of frequency above 200Hz in Hilbert spectrum. The result shows 800Hz-1000Hz component increases largely during 23 rd impact compared with the previous impact result. Thus, 800Hz-1000Hz component in Hilbert spectrum can be regarded as an indicator to diagnose winding fault. What's more, Short Circuit Impedance (SCI) experiment shows that SCI variation rate of A-phase changes 1 % after 24th impact and increases to -21.85% after 33rd impact. Suspended core experiment after the short circuit impact experiment reveals that severe winding mechanical fault occurs in both high voltage winding and medium voltage winding. Both of the results validate the correctness of Hilbert spectrum analysis of transient vibration response. Therefore, time-frequency vibration analysis can be used to monitor winding condition and diagnose winding fault.