22 May 2019 in IEEE Transactions on Power Delivery
The large current flowing through transformer windings during external short-circuit event causes strong vibration and the tank emits multi-frequency sound. This paper investigates the transient acoustic signal theoretically and experimentally, and proposes to monitor the winding condition with the spectrum of the acoustic signal. A two-wire model is first built as a basic unit of winding structure. The dynamic equation of the model is constructed based on principle of least action. The solution shows that the spectrum of the winding vibration contains half power frequency and its multiples in some cases. If the winding is loosened and deformed, the motion space and vibration amplitude would be enlarged and the natural frequency of winding would decrease. As a result, the vibration spectrum would contain half frequency and its odd multiples. Then the acoustic signal of a 110 kV transformer is measured on a short-circuit test platform. The acoustic time-frequency spectrums are consistent with the theoretical analysis. The half frequency ratio (HFR) of the acoustic signal is proposed to characterize the winding condition. The results prove that HFR of acoustic signal is a more sensitive indicator than the short-circuit reactance, which can characterize the cumulative process of short-circuit on the winding.
4 June 2019 in IEEE Transactions on Power Delivery
The ultimate objective for transformer winding fault diagnosis is fault location and even severity evaluation. The issue has been studied in many works, based on frequency response analysis (FRA), using numerical indices or mathematical correlation between ladder network and winding. This paper utilizes Gauss-Newton iteration algorithm (GNIA) to diagnose winding faults for its efficient search of optimal parameters and discrimination of linearly-dependent vectors. Three key problems are handled for the application of GNIA in this paper. The first problem is the establishment of connection between ladder network components and frequency response function (FRF) in GNIA. Another issue is the method to identify the faulty section to locate the defective winding position. The assessment of fault severity with GNIA data is another challenge. GNIA is applied on an air-cored model coil and a customized transformer successfully, with satisfactory diagnosis on deformation location and severity.
17 August 2016 in IEEE Transactions on Plasma Science
The atmospheric pressure plasma jet (APPJ) has become one of the hot research issues in plasma science and technology. In this paper, a cold Ar APPJ is generated using a dielectric barrier discharge configuration device equipped with an inverted tapered tube (ITT). Its characteristics are investigated by optical and electrical diagnostics, including discharge images, voltage-current waveforms, and optical emission spectra (OESs). The parameters, such as discharge power, gas temperature, and electronic excitation temperature (EET), are calculated and analyzed. All the above characteristics and parameters are compared with those of Ar APPJ generated with a conventional straight tube (CST). Furthermore, by numerical simulation, the flow field distribution of the ITT and CST is obtained and compared. The results show that the use of the ITT can raise Ar flow velocity, improve the distribution of Ar mole fraction, and Ar flow field. Moreover, the discharge power for the ITT is lower than that for the CST, so are the gas temperature and EET. The difference between theOESs is less obvious. Finally, the plasma plume develops along the inner surface of the CST with bits of apparent filamentary discharge, but along the central axis of the ITT and manifested as a stable and homogeneous discharge, which might be more promising for material processing and biomedical application in some cases.