Introduction. As a common interferer in clinical chemistry, lipemic specimens could be a source of significant analytical errors. Ultracentrifugation has been by far the only reliable, but an unavailable and expensive, method to eliminate the lipemic effect. Materials and Methods. Among the daily samples, those with triglyceride >400 mg/dL (4.6 mmol/L) and also turbid were selected, divided into three groups, based on triglyceride concentration, and three pooled serums were made for each group. Then all pooled serums were investigated by using a DIRUI biochemistry analyzer CS-800 for routine chemistry tests in different methods including direct measurement, serum blank, serum dilution, and measurement after ultracentrifugation. Results. According to our study, there were significant differences before and after ultracentrifugation in all lipemic levels and for all parameters except for alanine aminotransferase (ALT), alkaline phosphatase (ALP), bilirubin, and uric acid. Based on allowable inaccuracy for each parameter, calcium, magnesium, phosphorus, total protein, iron, total iron-binding capacity (TIBC), urea, and chloride are being influenced by all lipemic degree and neither serum dilution nor using serum blank is as effective as ultracentrifuge for elimination. Serum blank was a proper method of lipid removal for the measurement of glucose. Conclusion. Lipemia is a well-known interferer in clinical chemistry. One cannot avoid lipemia, but fortunately, severe lipemia is a rare phenomenon in the laboratory, and for assessment of some analytes in a lower degree of lipemia, use of serum blank eliminates the need for ultracentrifuge.
Chronic coronary artery disease (CAD) remains a significant global healthcare burden. Current risk assessment methods have notable limitations in early detection and risk stratification. Hence, there is an urgent need for innovative biomarkers that facilitate the premature CAD diagnosis, ultimately leading to reduction in associated morbidity and mortality rates. This review comprehensively examines recent advances in emerging biomarkers for CAD detection. Our analysis delves into various aspects of these biomarkers such as their mechanisms of action, roles in the pathophysiology of the disease, and different measurement techniques employed in clinical practice. Comparative assessment of biomarker performance between CAD patients and control groups was also presented relying on their sensitivity, specificity, and area under the curve at specific cutoff points. In this regard, prominent biomarkers including Tenascin-C, IL-37, PTX3, transthyretin, soluble interleukin-6 receptor α, and miR-15a are identified as having high diagnostic potential for chronic CAD that indeed showcase promising performance metrics. These findings underscore the role of novel biomarkers in enhancing CAD risk stratification and improving patient outcomes through early intervention. However, the pursuit of an ideal and inclusive biomarker continues due to the multifaceted nature of CAD. Future randomized controlled trials are essential to bridge the gap between research findings and clinical practice in order to augment the practical application of these biomarkers in routine healthcare settings.
1 July 2020 in International Medical Case Reports Journal
Primary Squamous cell carcinoma (SCC) of the kidney is rarely reported in the literature. It is usually associated with renal stone, and due to lack of clinical symptoms and radiological diagnostic features, patients often present at the late stages of the disease. We reported a 59-year-old woman presented with a longstanding history of flank pain and hematuria. Imaging techniques revealed enlargement of the right kidney associated with multiple staghorn stones. The patient subsequently underwent right radical nephrectomy, and histopathological examination of the mass revealed well-differentiated keratinized squamous cell carcinoma. There was no primary source for her SCC. Although the primary SCC of the kidney is a rare entity, it should be considered in patients with longstanding renal calculi, particularly for large staghorn stones of renal pelvis. On the other hand, conventional imaging could not detect this type of malignancy. In most cases, CT and MRI play an essential role in the diagnosis of such tumors.
1 December 2019 in International Medical Case Reports Journal
Chorangioma (placental hemangioma) is a benign non-trophoblastic neoplasm of the placenta. Small chorangiomas are usually asymptomatic, but the giant and multiple ones rarely have a favorable outcome. We report a case of 29 weeks of gestational age (after long-term secondary infertility) with premature labor pain and undiagnosed multiple chorangioma leading to hydrops fetalis and neonatal death. Here we report the clinicopathological features of our case and chorangioma in general, along with comparison of different vascular lesions of placenta in terms of incidence, risk factors, complications, histologic origin, macroscopic and light and electron microscopic features.
13 May 2021 in Journal of Analytical Methods in Chemistry
Background. Although the automation of instruments has reduced the variability of results and errors of analysis, in some laboratories, repeating a test to confirm its accuracy is still performed for critical and noncritical results. However, the importance of repeat testing is not well established yet, and there are no clear criteria for repeating a test. Materials and Methods. In this cross-sectional study, all repeated tests for 26 biochemical analytes (i.e., albumin, alkaline phosphatase (ALP), alanine aminotransferase (ALT), amylase, aspartate aminotransferase (AST), bilirubin total (BT), bilirubin direct (BD), blood urea nitrogen (BUN), calcium, chloride (Cl), cholesterol total (CholT), creatine kinase (CK), creatinine (Cr), glucose, gamma-glutamyl transferase (GGT), high-density lipoprotein-cholesterol (HDL-c), iron, lactate dehydrogenase (LDH), LDL-c, lipase, magnesium (Mg), phosphorus (Ph), protein total (ProtT), total iron binding capacity (TIBC), triglyceride (TG), and uric acid) were assessed in both critical and noncritical ranges over two consecutive months (routine subjective test repeats in the first month and rule-based repeats in the second month). To determine the usefulness of test repeats, differences between the initial and verified results were compared with the allowable bias, and repeat testing was considered necessary if it exceeded the allowable bias range. All causes of repeat testing, including linearity flags, delta checks, clinically significant values, and critical values, were also documented. All data, including the cause of repeats, initial and verified results, time, and costs in the two consecutive months, were transferred to Microsoft Excel for analysis. For comparison of data between the months, Student’s t-test was used. Results. A total of 7714 repeat tests were performed over two consecutive months. Although a significant decline (38%) was found in repeated tests in the second month ( < 0.001), there was no significant change in the percentage of unnecessary repeats (77% in the first month and 74% in the second month). In both consecutive months, AST and ALT were the most commonly repeated tests, and delta check was the most common cause of repeat testing. Mg, ALP, AST, and lipase showed the highest rates of necessary repeats, respectively (the least stable tests), while albumin, LDL, and CholT tests showed the highest rates of unnecessary repeats, respectively (the most stable tests). The total cost and delay in turnaround time (TAT) due to repeated testing decreased by 32% and 36%, respectively. Conclusion. Although repeat testing has been shown to be unnecessary in most cases, having a strict policy for repeat testing appears to be more valuable than avoiding it completely. Each laboratory is advised to establish its own protocol for repeat testing based on its own practice.
24 February 2022 in Cardiology Research and Practice
Background. The use of high-sensitivity troponin (hs-cTnI) assays is recommended in current guidelines for managing patients with acute coronary syndrome (ACS) symptoms. However, point-of-care (POC) assays are frequently used in emergency departments (EDs) to reduce turnaround time and length of stay. This study aimed to compare the results of POC-cTnI testing with those of the gold standard, automated central laboratory testing of troponin (i.e., hs-cTnI). The primary and secondary outcomes were the diagnostic performance of POC-cTnI in diagnosing acute myocardial infarction (AMI) and major adverse cardiovascular events (MACE) during 30 days, respectively. Materials and Methods. In this diagnostic accuracy study, 136 patients with suspected ACS who were referred or admitted to the Al Zahra Hospital, Shiraz, Iran, were included between March (2020) and July (2020). For the diagnosis of AMI, central laboratory cTnI levels were assessed at the time of presentation (0 hour) and reassessed at least 3 hours later. The POC-cTnI was measured at 0 hour in all patients and at 3 hours if a patient was diagnosed with AMI but had a 0-hour negative result for the POC-cTnI assay. Additionally, the 30-day follow-up period for these participants began on the day of the initial presentation to assess MACE. Results. Out of 180 patients, 136 patients (median age of 59.5 years; 57.5 male) were left for the qualitative POC-cTnI and hs-cTnI assays. In 86 (63.24) subjects, hs-cTnI was positive (either initial or serial); however, AMI was diagnosed in 85 patients according to positivity of troponin by hs-cTnI and clinical signs and symptoms, which were diagnosed by a cardiologist. The sensitivity, specificity, and negative predictive value of 0-hour POC-cTnI were observed to be 91.76 (95 CI: 83.7796.62), 98.04 (95 CI: 89.5599.95), and 87.72 (95 CI: 77.8293.56), respectively. Moreover, considering both the 0-hour and 3-hour POC-cTnI, all AMI cases were correctly identified, yielding a perfect test performance result. None of the 50 patients with negative cTnI results (by 0-hour and 3-hour POC-cTnI and hs-cTnI) experienced at least one MACE. Conclusion. In this small sample-size study, a new qualitative POC-cTnI assay was statistically equal to a hs-cTnI assay in terms of diagnostic accuracy for AMI or MACE in patients with suspected myocardial infarction. The POC-cTnI was observed to be acceptable for the identification of AMI and prediction of MACE in the ED environment.