20 February 2011 in Radiation Protection Dosimetry
The ORAMED (Optimization of RAdiation protection for MEDical staff) project is funded by EU-EURATOM within the 7° Framework Programme. Task 2 of the project is devoted to study the dose to the eye lens. The study was subdivided into various topics, starting from a critical revision of the operational quantity Hp(3), with the corresponding proposal of a cylindrical phantom simulating as best as possible the head in which the eyes are located, the production of a complete set of air kerma to dose equivalent conversion coefficients for photons from 10 keV to 10 MeV, and finally, the optimisation of the design of a personal dosemeter well suited to respond in terms of Hp(3). The paper presents some preliminary results.
24 October 2012 in Radiation Protection Dosimetry
In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were presented during a final workshop held in Barcelona in January 2011, the proceedings of which are available in the open literature. One of the ORAMED tasks was focused on the problem of eye-lens photon exposure of the medical staff, a topic that gained more importance especially after the ICRP decision to lower the limiting equivalent dose to 20 mSv per year. The present technical note has the scope, besides briefly summarising the physical reasons of the proposal and the practical implications, to provide, in tabular form, a set of air kerma to Hp(3) conversion coefficients based on the adoption of a theoretical cylindrical model that is well suited for reproduction of the mass and the shape of a human head.
30 November 2011 in Radiation Measurements
10 May 2010 in Radiation Protection Dosimetry
Interventional radiology, among guided X-rays procedures, is a methodology characterised by high level of doses, both for the patient and for the medical staff. The aim of the present study is to estimate the dose associated with coronary angiography procedures by means of numerical models (simplified and anthropomorphic) and MCNPX Monte Carlo code. Numerical estimates were supported by measurement performed with a dose area product meter that is commonly employed in such kind of studies. In the present work the main considerations and the preliminary results are presented.
7 June 2007 in Radiation Protection Dosimetry
Anthropomorphic computational models coupled with radiation transport codes are valuable tools in radiation protection dosimetry. In particular, they are very reliable for the estimate of the energy absorbed by different organs due to an incorporated radionuclide. MIRD-based stylised analytical models are widely accepted as standards but the recent generation of voxel phantoms, developed on real anatomical data derived from tomographic images, can represent a valid alternative for radiation protection and dosimetry purposes. Specific absorbed fraction evaluation and patient-specific dose estimate in nuclear medicine and radiotherapy could be considered as the optimal area for their implementation and use. On the other hand, the accuracy of organ and body structure representation guarantees an improved dose evaluation system also for radiation protection purposes in the workplace in case of accidental internal contamination. In the present work the voxel model NORMAN-05, a modified version of NORMAN (HPA, UK) model, has been employed with the Monte Carlo code MCNPX. Some preliminary investigations were carried out to evaluate the absorbed fractions for a series of source–target organ couples in case of gamma emitters and the organ absorbed doses in case of 90Sr incorporation. The paper summarises the main preliminary outcomes of such studies.
1 January 2009 in IFMBE Proceedings