Iuliia Shullie

Iuliia Shullie

Auto-generated profile, based on publicly available information

Iuliia Shullie

Vinnytsia National Technical University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2019 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
PLPetro Lezhniuk
Petro Lezhniuk
ABAnatolii Bondarchuk
Anatolii Bondarchuk
ISIuliia Shullie
Iuliia Shullie
Investigation and implementation of the fractal properties of electric load on civilian objects in order to efficiently predict and control electrical consumption

28 May 2026 in Herald of Khmelnytskyi National University. Technical sciences
Verified
Journal Article
Open access
ЮВЮрій Войтюк
Юрій Войтюк
АВАнатолій Волоцький
Анатолій Волоцький
МКМарина Кутіна
Марина Кутіна
ЮШЮлія Шуллє
Юлія Шуллє
The paper proposes and considers one of the current methods for organizing repair work on electrical equipment using specialized electrical repair enterprises. It is proposed to implement a mathematical model that describes the optimal distribution of repair work between specialized specialized enterprises, taking into account economic, technological and operational constraints. The model is formulated as an integral linear programming problem, which will allow increasing the efficiency of planning repairs of electrical equipment of industrial enterprises and energy facilities. The current stage of functioning of energy and industrial enterprises of Ukraine is associated with the operation of electrical equipment under martial law, which imposes special requirements for the reliability and uninterrupted operation of their work. Failure of electrical equipment involved in the implementation of basic technological processes and power supply is directly related to production downtime and increased operating costs. Along with this, modern electrical systems are characterized by increased requirements for electrical equipment, which complicates, and sometimes makes impossible, the processes of their maintenance and repair. In this regard, it is recommended in practice to carry out repairs of certain types and types of electrical equipment with the involvement of specialized electrical repair companies that perform repair or restoration work on certain types of electrical equipment and have the appropriate material and technical base and qualified personnel. The selection of a repair contractor is usually carried out without taking into account the complex influence of economic, technological and operational factors, which can reduce the efficiency of repairs. This necessitates the development of formalized approaches to the optimal use of specialized electrical repair companies.

29 May 2026 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Verified
Journal Article
Open access
DLDenys Lebed
Denys Lebed
YVYurii Voitiuk
Yurii Voitiuk
ISIullia Shullie
Iullia Shullie
The article is devoted to the assessment of the influence of the parameters of the output LC low-pass filter of a series power active filter on the flow of active power and the indicators of harmonic distortion of current and voltage in the system of a unified power quality regulator with a minimum installed power (UPQC-VAmin). The study of the LC filter was performed on the basis of modeling in the Matlab/Simulink environment for a three-phase four-wire system operating with a nonlinear load. The object of the analysis is to establish the relationship between the output inductance, the alternating voltage of the power source in the range (from 340 to 440 V) and key indicators: active power UPQC-VAmin, the harmonic distortion coefficients of the network current, voltages on the load and the network. Two common LC filter configurations were investigated: with a fixed capacitance of 100 μF with a variable inductance in a predetermined range from 0.1 to 3.1 mH and with stabilization of the resonant frequency within the minimum inductance and capacitance of the LC filter. The study was conducted for the calculated power supply circuit nodes selected within the voltage range varying in the range from –15 % to +10 % with a step of 10 V and an L-filter inductance of 0.1–3.1 mH with a step of 0.2 mH, which allowed constructing precision response surfaces and establishing the dynamics of the course of electromagnetic processes. The characteristic dependences of the active power flow in UPQC-VAmin on the input voltage were analyzed. It is proved that uncontrolled growth of inductance over 2 mH at constant capacitance leads to the emergence of resonance phenomena, which increase the level of harmonic distortion of the network current to 5.5 %. Zones of minimal voltage distortions on the load are determined, which confirms the reliability of the selected control system. According to the principle of Pareto optimality, the obtained results demonstrate the minimization of the coefficients of harmonic distortion of current and voltage.

30 September 2025 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Verified
Journal Article
Open access
PDF file
YVYurii Voitiuk
Yurii Voitiuk
AVAnatolii Volotskyi
Anatolii Volotskyi
ISIuliia Shullie
Iuliia Shullie
MKMaiia Kovalchuk
Maiia Kovalchuk
LDLaura Duissembayeva
Laura Duissembayeva
Important components of large and complex energy systems are electric energy supply systems, which perform the function of providing electric energy quality at the clamps of electric energy consumers. Development and realization of special methods and measures, enabling to synthesize the corresponding technical facilities, which will provide the possibility to obtain the basic indices of electric energy quality within the limits of DCTU (State standard of Ukraine) EN 50160:2014, is relevant technical problem. Taking into account the fact that quality indices correspond to different operation modes of electric energy supply systems consumers, the problem of searching methods, which would adequately represent the process of energy consumption, arises. In such operation conditions of modern systems of electric energy supply it is expedient to use the methods of searching optimal solutions which would enable to influence simultaneously the improvement (or non-worsening) of the quality indices of electric energy. The given paper considers theoretical aspects of using one of the most suitable methods for the solution of this problem, which relates to multicriterial ones, when it is not possible to express in simple terms the need to increase or decrease one efficiency criterion (quality index) and it is necessary to consider not one criterion but a set of partial criteria which form vector criterion. Corresponding mathematical models for one of the widely used problems of electric energy quality optimization have been formulated and considered. Practical example of their application has been presented, it will give the possibility to simplify the computations and provide adequate realization of optimization processes.

29 January 2026 in Herald of Khmelnytskyi National University. Technical sciences
Verified
Journal Article
Open access
МКМарина Кутіна
Марина Кутіна
ЮШЮлія Шуллє
Юлія Шуллє
ЮВЮрій Войтюк
Юрій Войтюк
The paper substantiates the application of the Theory of Similarity as an effective method for constructing a Diagnostic Model (DM) with a disturbance (or fault model), aimed at the operational and accurate determination of the technical condition of complex objects. The key idea lies in utilizing the dimensional information inherent in the system and process indicators as fundamental data for formalizing the model and deriving the target function. Traditional diagnostic models often face challenges such as unwieldiness, excessive sensitivity to noise, or the impossibility of achieving precise analytical description, particularly for objects characterized by a large number of interrelated parameters. The application of the Theory of Similarity offers an elegant approach to resolving these issues through the reduction of initial data and the transition to dimensionless characteristics, which significantly simplifies the subsequent analysis. The process of constructing the diagnostic model is based on the sequential application of the First and Second Theorems of Similarity. The Second Theorem of Similarity, or the πTheorem, serves as the foundation for describing the process in its criterial form. It postulates that any complete equation describing a physical process, when written in a specific system of units, can be expressed as an equation relating only dimensionless quantities (similarity criteria), which are derived from the indicators participating in the physical process. This theorem provides a potent mathematical advantage: it allows for the reduction of the number of variables from $m$ dimensional quantities down to (m – k) dimensionless criteria, where k represents the number of fundamental units of measurement. This variable reduction significantly streamlines both experimental investigations and mathematical analysis, making complex systems more manageable for diagnostic purposes. Once the criterial relationships are established, a necessary transition to a mathematical form is required to directly obtain the target function of the diagnostic model. For this purpose, the First Theorem of Similarity is employed. This theorem formulates the condition for similarity between processes: if two physical processes are similar, their corresponding similarity criteria are equal to each other. This principle allows for the establishment of the parametric form of the model, where the object’s fault or the change in its technical state is reflected through the variation in the values of the dimensionless criteria. Using the rule for transforming criteria allows for an efficient shift from the criterial form to the parametric form, which is the immediate objective of the diagnostic process. This shift is crucial for translating theoretical dimensionless relationships into a practical, measurable diagnostic tool. Consequently, the Theory of Similarity provides a formalized, structured, and economical (with respect to the number of variables) approach to fault modeling. The developed model allows for the effective utilization of internal information embedded within the dimensions of physical indicators to construct a target function that accurately reflects the object’s technical condition. This methodology offers a robust alternative to purely analytical or purely data-driven models by leveraging fundamental physical relationships in a simplified, dimensionless framework, enhancing both the rigor and practicality of the diagnostic system. The integration of dimensional analysis ensures that the resulting diagnostic function is physically meaningful and independent of the chosen system of units, a major advantage in cross-system applications. The $\pi$-theorem, by consolidating many variables into a few dimensionless groups, inherently provides a necessary level of abstraction, focusing the diagnostic effort on the most influential parameters and their ratios, rather than absolute values. This is essential for building resilient and universally applicable diagnostic tools for industrial and engineering systems. The parametric form derived via the First Theorem of Similarity serves as the final, quantitative output for real-time monitoring and fault detection.