Denys Lebed

Denys Lebed

Auto-generated profile, based on publicly available information

Denys Lebed

Vinnytsia National Technical University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Verified
Journal Article
Open access
PDF file
MBMykhailo Burbelo
Mykhailo Burbelo
OBOleksii Babenko
Oleksii Babenko
YLYurii Loboda
Yurii Loboda
DLDenys Lebed
Denys Lebed
OKOleg K. Kolesnytskyj
Oleg K. Kolesnytskyj
MMMurat Mussabekov
Murat Mussabekov
This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in case of voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The task of STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generated by the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However, at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solve this problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation. In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle of the voltage vector changes, which causes a failure in the operation of the regulator of the parallel compensator UPFC. W artykule opisano problematykę automatycznej regulacji mocy biernej za pomocą urządzeń elektronicznych FACTS (Flexible AC Transmission Systems): statycznego kompensatora synchronicznego (STATCOM) oraz regulatora przepływu mocy (UPFC). Za pomocą złożonego formularza rejestracyjnego określane są: napięcia w węzłach instalacji urządzenia FACTS i obciążenia, prądy obciążenia, źródeł zasilania i kompensatorów elektronicznych w przypadku niestabilności napięcia w węźle obciążenia sieci elektrycznej. Napięcia i prądy są wyznaczane metodą napięć węzłowych. Zadaniem STATCOM jest częściowa lub pełna kompensacja mocy biernej. Podczas spadku napięcia w węźle obciążenia, moc bierna generowana przez źródło zasilania maleje. STATCOM powinien częściowo lub w pełni skompensować nierównowagę mocy biernej tak szybko, jak to możliwe. Jednocześnie jednak nie jest możliwe pełne skompensowanie spadku napięcia. W celu rozwiązania tego problemu można zastosować szeregowo-równoległy lub równoległo-szeregowy układ UPFC. W wyniku zastosowania UPFC możliwe jest automatyczne podniesienie poziomu napięcia do akceptowalnych wartości za pomocą kompensatora szeregowego UPFC. Analiza pokazuje, że równoległo-szeregowy UPFC charakteryzuje się stabilnością działania. W przypadku zastosowania szeregowo-równoległego UPFC istnieją ograniczenia w zakresie możliwości regulacji składowej urojonej napięcia kompensatora szeregowego, ponieważ zmienia się kąt wektora napięcia, co powoduje awarię działania regulatora kompensatora równoległego UPFC.

1 August 2022 in Herald of Khmelnytskyi National University. Technical sciences
Verified
Journal Article
Closed access
MBMykhailo Burbelo
Mykhailo Burbelo
DLDenys Lebed
Denys Lebed
OLOleksandr Leshchenko
Oleksandr Leshchenko
VUVinnytsia National Technical University
Vinnytsia National Technical University
A voltage regulator on capacitors has been developed for the control circuit of a parallel active filter based on dq-theory with a block of sliding averaging current in the current control circuit i_d. It contains a delay unit, a digital low-pass filter of the first order FIR or IIR (depending on the variant of the considered scheme) and the unit “sgn”, which stabilizes the output signal. The voltage control circuit on the capacitor can be implemented entirely in digital signal processing and used instead of the analog PID controller, which is much more effective if you need to adapt the circuit to the load mode. Most analog filters suffer from phase distortion when signals at different frequencies are delayed by different amounts. Although it is still present in digital IIR filters. FIR filters are usually designed as a “linear phase”, which means that the filter has no phase distortion. Phase distortions occur due to the fact that signals of different frequencies are delayed differently when crossing the filter. For IIR filters, it is necessary to enter an additional factor that will regulate the group delay, during which the filter will delay the signal of a certain frequency. If you do the same for the FIR filter, you will see a straight horizontal line, which means that all signals are delayed by the same amount, which is good and will provide better signal quality. The unit “sgn” does not affect the process of maintaining the voltage on the capacitors and the speed of transients, its role is to enhance the compensatory capacity of the voltage regulator by filtering the digital signal. The selected filter, by automatically stabilizing the voltage on the capacitor provides a stable charge / discharge process of the capacitor and a high level of compensation of higher harmonics without significant additional generation of active power in the network. When used in the context of real-time analog systems, the digital filter sometimes has a problematic delay (input-output time difference) due to analog-to-digital and digital-to-analog conversion and smoothing. It is shown that by optimizing the charge / discharge time of the capacitor of the power active filter it is possible to achieve the minimum duration of the transient process with the minimum values of harmonic distortions.

1 January 2025 in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
Verified
Journal Article
Closed access
MBMykhailo Burbelo
Mykhailo Burbelo
OBOleksii Babenko
Oleksii Babenko
DLDenys Lebed
Denys Lebed

20 December 2023 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Verified
Journal Article
Open access
PDF file
ДЛДенис Юрійович Лебедь
Денис Юрійович Лебедь
МБМихайло Йосипович Бурбело
Михайло Йосипович Бурбело
This article is devoted to error analysis of the unified power quality regulator. In the context of the growing importance of reliable and high-quality power supply, power quality regulators are becoming key devices to ensure the stability of networks and meet the needs of domestic consumers. The paper proposes a comprehensive approach to error analysis of the unified power quality conditioner, the main purpose of which is to compensate for the impact of rapidly changing loads on power quality. At the same time, indicators of general harmonic distortion of the quality of electricity are analyzed, and factors such as the magnitude and duration of loads are also taken into account. A large part of the article is devoted to the study of the sources of errors in unified power quality conditioner. A comparison of the parallel-serial and series-parallel topologies of unified power quality conditioner is performed. The influence of the unified power quality conditioner control algorithm on the formation of errors of each topology is analyzed. Using Matlab/Simulink computer simulation tools, the article proposes a framework for error quantification, which allows accurate estimation of errors at various stages of unified power quality conditioner operation. This framework covers the Fourier series transformation of voltage and power for comprehensive estimation of error magnitudes. To confirm the effectiveness of the proposed error analysis and compensation strategies, the article presents graphs of simulation results in the time and frequency domains. Active and reactive power generation errors and voltage setpoint errors are described. These findings emphasize the ability of unified power quality conditioner to improve the quality of electricity, despite measurement errors. The main results include the analysis of deviations of voltage quality indicators, the establishment of a connection between compensation errors and deficiencies in the functioning of the system, as well as the development of recommendations for improving the efficiency of compensation devices.

29 May 2026 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Verified
Journal Article
Open access
DLDenys Lebed
Denys Lebed
YVYurii Voitiuk
Yurii Voitiuk
ISIullia Shullie
Iullia Shullie
The article is devoted to the assessment of the influence of the parameters of the output LC low-pass filter of a series power active filter on the flow of active power and the indicators of harmonic distortion of current and voltage in the system of a unified power quality regulator with a minimum installed power (UPQC-VAmin). The study of the LC filter was performed on the basis of modeling in the Matlab/Simulink environment for a three-phase four-wire system operating with a nonlinear load. The object of the analysis is to establish the relationship between the output inductance, the alternating voltage of the power source in the range (from 340 to 440 V) and key indicators: active power UPQC-VAmin, the harmonic distortion coefficients of the network current, voltages on the load and the network. Two common LC filter configurations were investigated: with a fixed capacitance of 100 μF with a variable inductance in a predetermined range from 0.1 to 3.1 mH and with stabilization of the resonant frequency within the minimum inductance and capacitance of the LC filter. The study was conducted for the calculated power supply circuit nodes selected within the voltage range varying in the range from –15 % to +10 % with a step of 10 V and an L-filter inductance of 0.1–3.1 mH with a step of 0.2 mH, which allowed constructing precision response surfaces and establishing the dynamics of the course of electromagnetic processes. The characteristic dependences of the active power flow in UPQC-VAmin on the input voltage were analyzed. It is proved that uncontrolled growth of inductance over 2 mH at constant capacitance leads to the emergence of resonance phenomena, which increase the level of harmonic distortion of the network current to 5.5 %. Zones of minimal voltage distortions on the load are determined, which confirms the reliability of the selected control system. According to the principle of Pareto optimality, the obtained results demonstrate the minimization of the coefficients of harmonic distortion of current and voltage.