Design and fabrication of microelectromechanical systems (MEMS) can be costly, time consuming, and necessitating accurate models for their behavior. Current theoretical models of bistable beams in MEMS devices are limited to numerical or small deformation models and current measurement techniques are unable to fully characterize these devices as they only determine thresholds or have resolutions that are too coarse to adequately explore the force-deflection relationship of bistable mechanisms. Two analytical models are developed: a stepped Euler-Bernoulli beam and a large deformation model. To validate these models, a new technique for measuring in-plane mechanical properties of MEMS devices is introduced that measures normal and lateral forces against a probe tip, while electrostatic actuation and a force-feedback loop maintain the desired tip position. This allows true displacement-controlled measurements along two axes and facilitates automated positioning. Measurements validate the large deformation model and show that Euler-Bernoulli beam theory is inadequate for modeling the mechanism's bistable behavior. A parameter study in edge width using the large deformation model accounts for discrepancies between predicted and measured forces. The model's utility is further demonstrated by an optimization study that redesigns the mechanism to be less sensitive to the edge width variation introduced in the manufacturing process.
The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. We review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. We summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.
The surface erosion of polyethylene is interrogated using pulsed x rays at the Z Machine (Sandia National Laboratories) and with proton beams at the Gamble II generator (Naval Research Laboratory) to validate a coupled model for volumetric thermal ablation, photoionization, finite-rate decomposition, and molecular recombination of radicals. The intense radiation pulses (up to ∼1014W/m2 over tens of nanoseconds) are used to generate one-dimensional vapor flows with low ionization fractions and a simplified geometry compared to typical laser ablation, allowing for evaluation of the model under local thermal equilibrium conditions. Areal momentum carried by the ensuing uniaxial hydrodynamic shock is used to indicate the extent of ablation. The threshold fluence for ablation is found to be in close correspondence with the bulk melt transition, and reasonable agreement with the model is obtained for peak temperatures in polyethylene up to 5500 K and heating rates up to 1011K/s where thermal decomposition reactions are also active.