Ni–Co/SiO2 composite coating was electrodeposited on the steel substrate. The coatings were characterized by X-ray diffraction and scanning electron microscopy. The microhardness of the composite coatings was studied by variation of the electroplating parameters, such as the pulse current (PC) and direct current (DC) electrodeposition methods, deposition temperature, electrolyte pH, concentration of surfactants, sodium dodecyl sulfate (SDS), and cetyltrimethylammonium bromide (CTAB). Zeta potential of SiO2 particles measurements was performed with various pH, SDS, and CTAB concentrations. The data depict that the hardness of Ni–Co/SiO2 nanocomposite coatings manufactured by PC electrodeposition increases with the increase of bath temperature, pH, SDS, and CTAB concentration up to 50°C, 4.6, 0.3, and 0.2 g/L, respectively. Beyond mentioned optimum values, the microhardness of nanocomposite coating decreases. Using DC method led to reduce the microhardness. Utilizing SiO2 microparticles instead of SiO2 nanoparticles for reinforcing resulted in declining the microhardness. The friction coefficient and wear results demonstrated that using PC method and nanosized particles led to reduce the friction coefficient and increase the resistance to wear. Anodic polarization results illustrated that using SiO2 nanoparticles and PC method to prepare coating caused corrosion resistance of coating in a 3.5 wt% NaCl solution to enhance.
18 January 2019 in Metallurgical and Materials Transactions A
Semi-solid processing (SSP) technology, due to its ability to provide near-net-shape components with properties far exceeding those of other casting technologies is considered as an alternative for forgings and investment castings. Conventional semi-solid forming, involving the use of heated billets, melt stirring or using cooling slopes require many processing steps and supplementary equipments. This article describes Narrow Melt Stream (NMS), as an alternative process for semi-solid processing of aluminum alloys that eliminates capital cost expenditures, reduces the number of steps required, and hence reduces the costs of making components with a globular structure. However, the applicability of this technique in producing globular structures in the large molds has not been explored. In the present study the results of a systematic investigation on the effects of mold size on the size and morphology of the globular structures formed by NMS processing of Al 356 alloy is reported. For this purpose, five different series of molds were employed. Each series consisted of three molds with identical volumes but different casting moduluses. By using these molds, the effects of casting modulus at constant casting size as well as the effect of casting volume on the size and shape factor of the globular structures in aluminum A356 samples prepared by NMS technique is reported.
9 February 2026 in IEEE Transactions on Applied Superconductivity
Bulk niobium is the standard material for superconducting RF cavities but requires operation at 2 K due to its critical temperature (Tc) of 9.3 K, leading to high cooling costs. Nb3Sn, with a higher Tc (∼18.2 K), allows operation at 4.2 K, reducing cryogenic demands and improving efficiency. Although Nb3Sn theoretically offers a higher quality factor (Q), achieving this in practice remains difficult. Co-sputtering Nb3Sn films on copper cavities may improve Q, thermal stability, and delay quenching at high accelerating fields. In this study, Nb3Sn films were co-sputtered on different substrates to investigate the Tc and lower critical field (Hc1). The films were deposited in a controlled atmosphere and analyzed using X-ray diffraction, resistivity measurements and superconducting quantum interference device magnetometry. The results confirm the successful formation of the Nb3Sn phase with well-defined superconducting transition. The measured Tc value for films grown on r-cut sapphire reached 17.8 K, close to the bulk Nb3Sn value. On the technically relevant substrate copper, a Tc value of 15 K was obtained. Notably, the Hc1 value was found to be not only higher than that for bulk Nb3Sn but also higher than that of pure Nb. A high value of Hc1 is critical for operating high Q cavities at accelerating fields above 20 MV/m.