Miloljub D. Lukovic

Miloljub D. Lukovic

Auto-generated profile, based on publicly available information

Miloljub D. Lukovic

Information Technology School-ITS, Zemun, Serbia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SAStanko O. Aleksic
Stanko O. Aleksic
NMNebojsa S. Mitrovic
Nebojsa S. Mitrovic
MLMiloljub D. Lukovic
Miloljub D. Lukovic
Sonja Veljović JovanovićSonja Veljović Jovanović
Sonja Veljović Jovanović
SLSnezana G. Lukovic
Snezana G. Lukovic
OAObrad S. Aleksic
Obrad S. Aleksic
A new ground temperature profile sensor comprising of a row of thermistors enables a large number of equidistantly arranged measuring points. The row of thermistors was formed using a group of negative temperature coefficient thick film segmented thermistors connected in series. After that calibration of the DC thermistor resistance R was performed at room temperature and the sensor was placed in a hole drilled on the lawn. DC resistances R of the row of thermistors were measured versus depth z as a parameter and converted to actual temperature T(z) in the ground using the Steinhart-Hart equation. The temperature profile of the ground depending on deepness z and time t as a function T(t, z) was measured on different days during one year in the early morning and in the afternoon. The temperature at the ground surface was compared with the temperature of the deepest sensor point in the ground. Thermal diffusivity D of the ground was determined using measured data T(t, z) in the periods of steady ground temperatures. The new ground temperature profile sensor was realized to investigate the correlation between air and ground temperature, observation of ground temperature profile changes and heat exchange (heat transfer, diffusion, gradient, and heat flow direction) through the ground top layer and finally humidity estimation versus deepness.

24 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
MNMaria Vesna Nikolic
Maria Vesna Nikolic
MDMilena Dojcinovic
Milena Dojcinovic
Zorka VasiljevicZorka Vasiljevic
Zorka Vasiljevic
MLMiloljub D. Lukovic
Miloljub D. Lukovic
NLNebojsa J. Labus
Nebojsa J. Labus
Nanocomposite Zn2SnO4/SnO2 powder was obtained by solid state synthesis from homogenized starting nanopowders of ZnO and SnO2, mixed in the 1:1 molar ratio, structurally and morphologically characterized using X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM). Thick film paste was made by adding organic vehicles to the obtained powder. Three to five layers (layer thickness approx. 12 μm) were screen printed on alumina substrate with small test PdAg electrodes and fired at 600oC for 30 minutes. SEM analysis confirmed formation of a porous structure suitable for humidity sensing. Impedance response was studied at the working temperatures of 25 and 50oC in a humidity chamber where the relative humidity (RH) was 30-90% and measured frequency 42 Hz – 1 MHz. With increase in film thickness the overall sensor impedance increased. It reduced at 100 Hz from 36 to 0.25 MΩ (60 μm), from 23.4 to 0.25 MΩ (48 μm) and from 6.8 to 0.02 MΩ (36 μm) at 25 oC, while at 50 oC and also 100 Hz it reduced from 14 MΩ to 0.72 MΩ (48 μm) for RH 30 and 90%, respectively. The response (8 s) and recovery (10 s) was fast, showing that this nanocomposite has potential for application in humidity sensing.

16 July 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SAStanko O. Aleksic
Stanko O. Aleksic
NMNebojsa S. Mitrovic
Nebojsa S. Mitrovic
ZNZoran Nikolic
Zoran Nikolic
MLMiloljub D. Lukovic
Miloljub D. Lukovic
NONina Obradovic
Nina Obradovic
SLSnezana G. Lukovic
Snezana G. Lukovic
NTC thick-film segmented thermistors were used as anemometer sensing devices. They were screen printed of thick-film thermistor paste based on modified NiMn2O4 fine powder, organic vehicle and glass frit. Their electrical properties such as resistance vs. temperature R(T) and thermistor exponential factor B were obtained using measurements in the climatic test chamber. An uniaxial anemometer was formed using a thick-film segmented thermistor which was placed in the hole drilled in rectangular piece of thermally insulating material. The uniaxial anemometer was used for the optimization of operating point of segmented thermistors as self-heating / wind sensing devices. The DC supply voltage was correlated with the air temperature sub-ranges (RCV). The power save mode such as 30s self-heating/5 min pause was used to measure the thermistor response on stable wind blow. The three-axis’ anemometer was formed using five sensor devices placed in five holes drilled in the cubical piece of thermally insulating material: three thermistor sensors measure wind speed on the x, y, z — axes, the fourth sensor Pt 1000 measures the air temperature T, while the fifth sensor (capacitive type) measures humidity H. The obtained sensitivity and inaccuracy were compared with respective ones of other anemometers.

1 January 2024 in Science of Sintering
Verified
Journal Article
Open access
PDF file
SAStanko O. Aleksic
Stanko O. Aleksic
NONina Obradovic
Nina Obradovic
NMNebojša S. Mitrović
Nebojša S. Mitrović
MLMiloljub D. Luković
Miloljub D. Luković
A powder of Cu0.2Ni0.5Zn1.0 Mn1.3O4 composition for custom thermistor was prepared by using the respective mixture of metal oxides and solid state reaction at 1000 ?C/4h in air. The obtained thermistor powder was milled in the planetary ball mill and agate mill for a prolonged time to achieve submicron powder. The prepared thermistor powder was further characterized by using XRD and SEM techniques. After that, the thermistor powder was pressed into small disc-shaped samples and sintered at 1150?C/2h. The sintered samples were also characterized by using XRD and SEM. The main electrical properties such as nominal resistance R and thermistor exponential factor B were measured in the climatic test chamber. After that, the thick film paste was prepared using the same powder, an organic vehicle and a glass frit. The paste was printed on alumina substrate, dried at 150 =?C /30 min and sintered in air at 850?C /10 min in a hybrid conveyor furnace. Planar electrodes were printed on the sintered NTC thermistor layer using PdAg thick film paste. The electric properties of the sintered thick film thermistor were also measured in the climatic test chamber. The obtained results were used for development of novel self-heating thermistor applications.

16 June 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
MNMaria Vesna Nikolic
Maria Vesna Nikolic
MLMiloljub D. Lukovic
Miloljub D. Lukovic
A porous MgFe2O4-Fe2O3-SnO2 bulk compound with varying SnO2 content was obtained by sintering an appropriate mixture of magnesium oxide, hematite and tin oxide nanopowders at 1000 and 1100 °C. The obtained structure was confirmed by X-ray diffraction analysis. Scanning electron microscopy was used to analyze sample morphology, showing that the addition of SnO2 resulted in an inhomogeneous microstructure with smaller grain size especially at 1000 °C. Significant grain growth of hematite grains was noted at 1100 °C. The influence of relative humidity in the range 30–90% was monitored at room temperature (25 °C) in the frequency range 42 Hz- 1 MHz. The highest reduction of impedance with humidity was noted at lower frequency. Addition of low amounts of SnO2 and sintering at 1000 °C resulted in the highest sensitivity at 105 Hz of 0.391 MΩ/%RH in the RH30–90% range, while the compound with the highest amount of SnO2 showed the largest decrease in impedance with increase in relative humidity ~26 times. All samples showed low hysteresis (below 2%). Complex impedance data was analyzed using equivalent circuits reflecting the dominant influence of the grain boundary in the lower relative humidity range (30–60%) and both grain boundary and grain components in the higher relative humidity range (60–90%).

7 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SAStanko O. Aleksic
Stanko O. Aleksic
NMNebojsa S. Mitrovic
Nebojsa S. Mitrovic
MLMiloljub D. Lukovic
Miloljub D. Lukovic
SLSnezana G. Lukovic
Snezana G. Lukovic
NNNenad Nikolic
Nenad Nikolic
Novel heat loss flowmeter for water consists of the small plastic housing and two NTC thick film segmented thermistors with reduced dimensions placed along the main axis. The segmented thermistors were printed using the modified nickel-manganese paste and sintered in air at 850°C / 10 min in the conveyor furnace. The first thermistor Th1 is cold and measures input water temperature and the second thermistor Th2 is selfheated at constant voltage and measures water flow rate. A short switch mode operating cycle for the self-heating thermistor was introduced: 30s of self-heating from the initial state and after that 90s of natural cooling to the initial state. The self heating DC current in 30th second I30 is recognized as the flowmeter response on stable water flow Q, while input water temperature Tw was used as a parameter. The flowmeter temperature range was divided in a few sub-ranges and adaptive DC voltage power supply (RCV) was introduced for each sub-range. The flowmeter measuring range and inaccuracy were compared with respective ones of other flowmeters.