1 October 2020 in Safety Science
We provide research findings on the physics of aerosol and droplet dispersion relevant to the hypothesized aerosol transmission of SARS-CoV-2 during the current pandemic. We utilize physics-based modeling at different levels of complexity, along with previous literature on coronaviruses, to investigate the possibility of airborne transmission. The previous literature, our 0D-3D simulations by various physics-based models, and theoretical calculations, indicate that the typical size range of speech and cough originated droplets (d⩽20μm) allows lingering in the air for O(1h) so that they could be inhaled. Consistent with the previous literature, numerical evidence on the rapid drying process of even large droplets, up to sizes O(100μm), into droplet nuclei/aerosols is provided. Based on the literature and the public media sources, we provide evidence that the individuals, who have been tested positive on COVID-19, could have been exposed to aerosols/droplet nuclei by inhaling them in significant numbers e.g. O(100). By 3D scale-resolving computational fluid dynamics (CFD) simulations, we give various examples on the transport and dilution of aerosols (d⩽20μm) over distances O(10m) in generic environments. We study susceptible and infected individuals in generic public places by Monte-Carlo modelling. The developed model takes into account the locally varying aerosol concentration levels which the susceptible accumulate via inhalation. The introduced concept, ’exposure time’ to virus containing aerosols is proposed to complement the traditional ’safety distance’ thinking. We show that the exposure time to inhale O(100) aerosols could range from O(1s) to O(1min) or even to O(1h) depending on the situation. The Monte-Carlo simulations, along with the theory, provide clear quantitative insight to the exposure time in different public indoor environments.
4 June 2015 in Nano Letters
1 April 2013 in Investigative Ophthalmology & Visual Science
Purpose.: To investigate microrobots as an assistive tool for minimally invasive intraocular surgery and to demonstrate mobility and controllability inside the living rabbit eye. Methods.: A system for wireless magnetic control of untethered microrobots was developed. Mobility and controllability of a microrobot are examined in different media, specifically vitreous, balanced salt solution (BSS), and silicone oil. This is demonstrated through ex vivo and in vivo animal experiments. Results.: The developed electromagnetic system enables precise control of magnetic microrobots over a workspace that covers the posterior eye segment. The system allows for rotation and translation of the microrobot in different media (vitreous, BSS, silicone oil) inside the eye. Conclusions.: Intravitreal introduction of untethered mobile microrobots can enable sutureless and precise ophthalmic procedures. Ex vivo and in vivo experiments demonstrate that microrobots can be manipulated inside the eye. Potential applications are targeted drug delivery for maculopathies such as AMD, intravenous deployment of anticoagulation agents for retinal vein occlusion (RVO), and mechanical applications, such as manipulation of epiretinal membrane peeling (ERM). The technology has the potential to reduce the invasiveness of ophthalmic surgery and assist in the treatment of a variety of ophthalmic diseases.
1 July 2014 in Advanced Healthcare Materials
GCGeorge Chatzipirpiridis
+3
7 July 2014 in Expert Opinion on Drug Delivery
GCGeorge Chatzipirpiridis
+3
Ocular microrobots have the potential to change the way in which we treat a variety of diseases at the anterior and the posterior segments of the eye. Wireless manipulation and positioning of drug delivery magnetic millimeter and submillimeter platforms into the eye constitute a potential route for minimally invasive targeted therapy. However, the field is still in its infancy and faces challenges related to the fabrication, control an interaction with complex biological environments. This review briefly introduces the complex anatomy and physiology of the eye, which renders limitations to the current treatments of ocular diseases. The topical administration of eye drops, intravitreal injections and drug delivery implants is briefly mentioned together with their drawbacks. The authors also analyze the minimally invasive microrobotic approach as an alternative method and report the recent advancements in the fabrication, control, manipulation and drug delivery. Although microrobotics is a young field, a significant amount of work has been developed to face different challenges related to the minimally invasive manipulation of microdevices in the eye. Current research is already at the state of in vivo testing for systems and their biocompatibility. It is expected that the general concepts acquired will soon be applied for specific interventions, especially for posterior eye pathologies.
29 May 2014 in RSC Advances
We report a cooperative transport strategy that uses engineered microbars and multiple helical microcarriers. Cooperation of microcarriers generates higher propulsive forces while application of forces at multiple locations results in motion control with multiple degrees of freedom.