Murat Emrah Maviş

Murat Emrah Maviş

Auto-generated profile, based on publicly available information

Murat Emrah Maviş

Bahcesehir University Faculty of Pharmacy Department of Analytical Chemistry

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2019 in Alinteri Journal of Agriculture Sciences
Verified
Journal Article
Open access
PDF file
ÖBÖzlem Bi̇lGi̇n
Özlem Bi̇lGi̇n
UÇUğur Çarli
Uğur Çarli
SESelahattin Erdogan
Selahattin Erdogan
MMMurat Emrah Mavi̇ş
Murat Emrah Mavi̇ş
GGGökçe Göksu Gürsu
Gökçe Göksu Gürsu
MYMuhitdin Yilmaz
Muhitdin Yilmaz
LC-MS/MS was used to determine the amino acid composition in muscle, ovary and liver of whiting, Merlangus merlangus euxinus, caught off the coast of Sinop province in the Black Sea. A total of 19 amino acids (AA) were found in the different samples. The essential amino acids (EAA) in the different tissues of whiting were 55.9% in the meat, 54.8% in the ovary and 51.7% in the liver of the total amino acids. The AA contents except for Arg, Glu, Pro and Tau in meat and ovary of whiting were not significantly different (P > 0.05), but the AA contents except for Cys, Tyr, Asp, Orn and Tau of these two tissues were significantly (P < 0.05) higher than the AA contents of the liver. These results showed that whiting ovaries have approximately as much protein as the meat.

1 May 2023 in Bioanalysis
Verified
Journal Article
Closed access
NÇNeşe Ular Çağatay
Neşe Ular Çağatay
MMMurat Emrah Maviş
Murat Emrah Maviş
SESezin Erarpat
Sezin Erarpat
SBSezgin BAKIRDERE
Sezgin BAKIRDERE
Aim: An accurate and sensitive analytical method was proposed to detect some steroid hormones in biological samples. Materials & methods: An Fe3O4/reduced graphene oxide nanocomposite-based dispers...

31 December 2024 in Eurasian Journal of Biological and Chemical Sciences
Verified
Journal Article
Closed access
MMMurat Emrah Maviş
Murat Emrah Maviş
NÇNeşe Ular Çağatay
Neşe Ular Çağatay
GGGökçe Göksu Gürsu
Gökçe Göksu Gürsu
Nitrosamines (NAs) are classified as probable or possible human carcinogens by the International Agency for Research on Cancer (IARC) and the presence of these impurities has resulted in numerous drug recalls from the market. In April 2020, ranitidine which is prescribed to reduce the amount of acid secreted by the stomach has been recalled owing to contamination with NAs. In this work, a simple and sensitive method for simultaneous determination of 10 NAs were developed, utilizing atmospheric pressure chemical ionisation source coupled liquid chromatography tandem mass spectrometer (LC-APCI-MS/MS). By performing dynamic multiple reaction monitoring (dMRM) mode, 10 NAs were separated on a Poroshell HPH C18 (4.6 x 150 mm, 2.7 µm) column with gradient elution implementing mobile phase A consisting of 0.2 % formic acid in water and mobile phase B consisting of methanol in 17 min. The proposed analytical method was successfully implemented in active pharmaceutic ingredient (API) of ranitidine with a water-based extraction procedure. Good linearity with a correlation coefficient (R2) ≥ 0.994 was accomplished over the concentration in range of 0.5–50 ng/mL. The limits of detection (LODs) ranged in 0.06–0.17 ng/mL and limits of quantitation (LOQs) ranged in 0.21-0.58 ng/mL of the method met thresholds of US Food and Drug Administration (US-FDA) and European Medicines Agency (EMA) for testing of NAs. The accuracy of the developed method ranged from 83.1% to 111.9 % and the percent relative standard deviation (%RSD) was ≤ 8.9.

29 January 2026 in Plant Biosystems
Verified
Journal Article
Closed access
PDF file
NYNurdan Yazici
Nurdan Yazici
EOESRA EROGLU OZKAN
ESRA EROGLU OZKAN
Emel Mataracı-KaraEmel Mataracı-Kara
Emel Mataracı-Kara
YYYagmur Yazici
Yagmur Yazici
NÇNese Ular Çağatay
Nese Ular Çağatay
MMMurat Emrah Maviş
Murat Emrah Maviş

4 September 2026 in Materials Research Express
Verified
Journal Article
Open access
PDF file
AAAla M M Awad
Ala M M Awad
UEUgur Erdemir
Ugur Erdemir
MMMurat Emrah Mavis
Murat Emrah Mavis
GGGokce Goksu Gursu
Gokce Goksu Gursu
SÖSevda Özel
Sevda Özel
EYEsra Yildiz
Esra Yildiz
This study investigated the long-term release of bisphenol A-glycidyl methacrylate (Bis-GMA), ethoxylated bisphenol A dimethacrylate (Bis-EMA), and urethane dimethacrylate (UDMA) from conventional and bulk-fill resin composites polymerized using different light-curing units and curing times. Three bulk-fill composites and one conventional resin composite were evaluated. Eighty specimens were prepared using standardized metal molds (2 mm × 8 mm for the conventional composite and 4 mm × 8 mm for the bulk-fill composites) and polymerized using either a halogen (Optilux 501) or light-emitting diode (LED; Demi Ultra) curing unit for 20 s or 40 s ( n = 5). The specimens were stored in a 75% ethanol/water solution, and monomer release was analyzed after 24 h, 1 week, 1 month, and 6 months using liquid chromatography-tandem mass spectrometry. Data were analyzed using multivariate ANOVA, repeated-measures ANOVA, Tukey HSD, and Tamhane’s T2 tests ( α = 0.05). Both curing-unit type and curing time significantly influenced monomer release ( p < 0.001). The LED curing unit resulted in lower monomer release than the halogen unit under the tested experimental conditions, while extending curing time from 20 s to 40 s significantly reduced monomer elution. Monomer release remained detectable throughout the six-month observation period. When all experimental conditions were considered collectively, UDMA exhibited the highest overall release and Bis-EMA the lowest, although material- and time-dependent variations were observed. Tetric EvoCeram Bulk Fill released significantly higher amounts of UDMA and Bis-GMA than the other investigated composites ( p < 0.001). Within the limitations of this study, both curing conditions and material composition significantly influenced long-term monomer release. These findings highlight the combined contribution of composite formulation and curing protocol to the release behavior of major resin-matrix monomers from contemporary resin composites.