Parallel imaging is a robust method for accelerating the acquisition of magnetic resonance imaging (MRI) data, and has made possible many new applications of MR imaging. Parallel imaging works by acquiring a reduced amount of k‐space data with an array of receiver coils. These undersampled data can be acquired more quickly, but the undersampling leads to aliased images. One of several parallel imaging algorithms can then be used to reconstruct artifact‐free images from either the aliased images (SENSE‐type reconstruction) or from the undersampled data (GRAPPA‐type reconstruction). The advantages of parallel imaging in a clinical setting include faster image acquisition, which can be used, for instance, to shorten breath‐hold times resulting in fewer motion‐corrupted examinations. In this article the basic concepts behind parallel imaging are introduced. The relationship between undersampling and aliasing is discussed and two commonly used parallel imaging methods, SENSE and GRAPPA, are explained in detail. Examples of artifacts arising from parallel imaging are shown and ways to detect and mitigate these artifacts are described. Finally, several current applications of parallel imaging are presented and recent advancements and promising research in parallel imaging are briefly reviewed. J. Magn. Reson. Imaging 2012;36:55–72.

10 December 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
FGFelix Glang
Felix Glang
ADAnagha Deshmane
Anagha Deshmane
SPSergey Prokudin
Sergey Prokudin
FMFlorian Martin
Florian Martin
KHKai Herz
Kai Herz
MZMoritz Zaiss
Moritz Zaiss
Purpose: Calculation of sophisticated MR contrasts often requires complex mathematical modeling. Data evaluation is computationally expensive, vulnerable to artifacts, and often sensitive to fit algorithm parameters. In this work, we investigate whether neural networks can provide not only fast model fitting results, but also a quality metric for the predicted values, so called uncertainty quantification, investigated here in the context of multi‐pool Lorentzian fitting of CEST MRI spectra at 3T.Methods: A deep feed‐forward neural network including a probabilistic output layer allowing for uncertainty quantification was set up to take uncorrected CEST‐spectra as input and predict 3T Lorentzian parameters of a 4‐pool model (water, semisolid MT, amide CEST, NOE CEST), including the B0 inhomogeneity. Networks were trained on data from 3 subjects with and without data augmentation, and applied to untrained data from 1 additional subject and 1 brain tumor patient. Comparison to conventional Lorentzian fitting was performed on different perturbations of input data.Results: The deepCEST 3T networks provided fast and accurate predictions of all Lorentzian parameters and were robust to input perturbations because of noise or B0 artifacts. The uncertainty quantification detected fluctuations in input data by increase of the uncertainty intervals. The method generalized to unseen brain tumor patient CEST data.Conclusions: The deepCEST 3T neural network provides fast and robust estimation of CEST parameters, enabling online reconstruction of sophisticated CEST contrast images without the typical computational cost. Moreover, the uncertainty quantification indicates if the predictions are trustworthy, enabling confident interpretation of contrast changes.

15 November 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ADAnagha Deshmane
Anagha Deshmane
MZMoritz Zaiss
Moritz Zaiss
TLTobias Lindig
Tobias Lindig
KHKai Herz
Kai Herz
MSMark Schuppert
Mark Schuppert
KSKlaus Scheffler
Klaus Scheffler
Purpose: For clinical implementation, a chemical exchange saturation transfer (CEST) imaging sequence must be fast, with high signal‐to‐noise ratio (SNR), 3D coverage, and produce robust contrast. However, spectrally selective CEST contrast requires dense sampling of the Z‐spectrum, which increases scan duration. This article proposes a compromise: using a 3D snapshot gradient echo (GRE) readout with optimized CEST presaturation, sampling, and postprocessing, highly resolved Z‐spectroscopy at 3T is made possible with 3D coverage at almost no extra time cost.Methods: A 3D snapshot CEST sequence was optimized for low‐power CEST MRI at 3T. Pulsed saturation was optimized for saturation power and saturation duration. Spectral sampling and postprocessing (B0correction, denoising) was optimized for spectrally selective Lorentzian CEST effect extraction. Reproducibility was demonstrated in 3 healthy volunteers and feasibility was shown in 1 tumor patient.Results: Low‐power saturation was achieved by a train of 80 pulses of duration tp = 20 ms (total saturation time tsat= 3.2 seconds at 50% duty cycle) with B1= 0.6 μT at 54 irradiation frequency offsets. With the 3D snapshot CEST sequence, a 180 × 220 × 54 mm field of view was acquired in 7 seconds per offset. Spectrally selective CEST effects at +3.5 and –3.5 ppm were quantified using multi‐Lorentzian fitting. Reproducibility was high with an intersubject coefficient of variation below 10% in CEST contrasts. Amide and nuclear overhauser effect CEST effects showed similar correlations in tumor and necrosis as show in previous ultra‐high field work.Conclusion: A sophisticated CEST tool ready for clinical application was developed and tested for feasibility.

29 March 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SGSteffen Goerke
Steffen Goerke
YSYannick Soehngen
Yannick Soehngen
ADAnagha Deshmane
Anagha Deshmane
MZMoritz Zaiss
Moritz Zaiss
JBJohannes Breitling
Johannes Breitling
PBPeter Bachert
Peter Bachert

23 June 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KHKai Herz
Kai Herz
TLTobias Lindig
Tobias Lindig
ADAnagha Deshmane
Anagha Deshmane
JSJens Schittenhelm
Jens Schittenhelm
MSMarco Skardelly
Marco Skardelly
MZMoritz Zaiss
Moritz Zaiss
Purpose: The aim of this study was to translate the T1ρ‐based dynamic glucose‐enhanced (DGEρ) experiment from ultrahigh magnetic field strengths to a clinical field strength of 3 T. Although the protocol would seem to be as simple as gadolinium‐enhanced imaging, several obstacles had to be addressed, including signal‐to‐noise ratio (SNR), robustness of contrast, and postprocessing, especially motion correction.Methods: Spin‐lock based presaturation and a 3D gradient‐echo snapshot readout were optimized for 3 T with regard to robustness, chemical exchange saturation transfer effect strength, and SNR. Postprocessing steps, including dynamic B0 and motion correction, were analyzed and optimized in 7 healthy volunteers. The final protocol, including glucose injection, was applied to 3 glioblastoma patients.Results: With appropriate postprocessing, motion‐related artifacts could be drastically reduced, and an SNR of approximately 90 could be achieved for a single dynamic measurement. In 2 patients with blood–brain barrier breakdown, a significant glucose uptake could be observed with a DGEρ effect strength in the range of 0.4% of the water signal. Thorough analysis of possible residual motion revealed that the statistical evidence can decrease when tested against pseudo effects attributed to uncorrected motion.Conclusion: DGEρ imaging was optimized for clinical field strengths of 3 T, and a robust protocol was established for broader application. Early experience shows that DGEρ seems possible at 3 T and could not only be attributed to motion artifacts. Observed DGEρ maps showed unique patterns, partly matching with the T1‐ce tumor ring enhancement. However, effect sizes are small and careful clinical application is necessary.