Nicole Seiberlich

Prof. Dr. Nicole Seiberlich


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2013 in Nature
Verified
Journal Article
Open access
PDF file
DMDan Ma
Dan Ma
VGVikas Gulani
Vikas Gulani
NSNicole Seiberlich
Nicole Seiberlich
KLKecheng Liu
Kecheng Liu
JSJeffrey L. Sunshine
Jeffrey L. Sunshine
MGMark A. Griswold
Mark A. Griswold
Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization—which we term ‘magnetic resonance fingerprinting’ (MRF)—that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.

13 June 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ADAnagha Deshmane
Anagha Deshmane
VGVikas Gulani
Vikas Gulani
MGMark A. Griswold
Mark A. Griswold
NSNicole Seiberlich
Nicole Seiberlich
Parallel imaging is a robust method for accelerating the acquisition of magnetic resonance imaging (MRI) data, and has made possible many new applications of MR imaging. Parallel imaging works by acquiring a reduced amount of k‐space data with an array of receiver coils. These undersampled data can be acquired more quickly, but the undersampling leads to aliased images. One of several parallel imaging algorithms can then be used to reconstruct artifact‐free images from either the aliased images (SENSE‐type reconstruction) or from the undersampled data (GRAPPA‐type reconstruction). The advantages of parallel imaging in a clinical setting include faster image acquisition, which can be used, for instance, to shorten breath‐hold times resulting in fewer motion‐corrupted examinations. In this article the basic concepts behind parallel imaging are introduced. The relationship between undersampling and aliasing is discussed and two commonly used parallel imaging methods, SENSE and GRAPPA, are explained in detail. Examples of artifacts arising from parallel imaging are shown and ways to detect and mitigate these artifacts are described. Finally, several current applications of parallel imaging are presented and recent advancements and promising research in parallel imaging are briefly reviewed. J. Magn. Reson. Imaging 2012;36:55–72.

11 January 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
FBFelix A. Breuer
Felix A. Breuer
MBMartin Blaimer
Martin Blaimer
MMMatthias F. Mueller
Matthias F. Mueller
NSNicole Seiberlich
Nicole Seiberlich
RHRobin M. Heidemann
Robin M. Heidemann
PJPeter M. Jakob
Peter M. Jakob
The CAIPIRINHA (Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration) concept in parallel imaging has recently been introduced, which modifies the appearance of aliasing artifacts during data acquisition in order to improve the subsequent parallel imaging reconstruction procedure. This concept has been successfully applied to simultaneous multi‐slice imaging (MS CAIPIRINHA). In this work, we demonstrate that the concept of CAIPIRINHA can also be transferred to 3D imaging, where data reduction can be performed in two spatial dimensions simultaneously. In MS CAIPIRINHA, aliasing is controlled by providing individual slices with different phase cycles by means of alternating multi‐band radio frequency (RF) pulses. In contrast to MS CAIPIRINHA, 2D CAIPIRINHA does not require special RF pulses. Instead, aliasing in 2D parallel imaging can be controlled by modifying the phase encoding sampling strategy. This is done by shifting sampling positions from their normal positions in the undersampled 2D phase encoding scheme. Using this modified sampling strategy, coil sensitivity variations can be exploited more efficiently in multiple dimensions, resulting in a more robust parallel imaging reconstruction. Magn Reson Med, 2006.

9 December 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
YJYun Jiang
Yun Jiang
DMDan Ma
Dan Ma
NSNicole Seiberlich
Nicole Seiberlich
VGVikas Gulani
Vikas Gulani
MGMark A. Griswold
Mark A. Griswold

1 August 2017 in Progress in Nuclear Magnetic Resonance Spectroscopy
Verified
Journal Article
Closed access
JHJesse Hamilton
Jesse Hamilton
DFDominique Franson
Dominique Franson
NSNicole Seiberlich
Nicole Seiberlich

1 April 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JHJesse I. Hamilton
Jesse I. Hamilton
YJYun Jiang
Yun Jiang
YCYong Chen
Yong Chen
DMDan Ma
Dan Ma
WLWei-Ching Lo
Wei-Ching Lo
NSNicole Seiberlich
Nicole Seiberlich