Background: Maintenance of thermal homeostasis is of crucial importance in the anesthetized pediatric patient. Gold‐standard methods for central core temperature measurement are however inappropriately invasive and impractical in daily practice. The SpotOn sensor uses zero‐heat‐flux thermometry technology and claims to bypass the invasiveness of classical methods and still accurately display central core temperatures. Up to date no formal analysis of this method in children has taken place.Aims: The primary objective was to assess the accuracy in comparison with esophageal temperature; the secondary objective concerned the safety of the SpotOn sensor in the pediatric patients.Methods: Fifty‐four children aged 1‐12 years with an American Society of Anesthesiology classification I or II scheduled to undergo elective surgical procedures under general anesthesia for a minimum of 30 minutes were included. Exclusion criteria included: fragile forehead skin, procedures impeding proper SpotOn placement, thoracoscopic or gastroesophageal procedures, coagulopathy, hemodynamic instability, or vasoactive medication use. After sevoflurane induction, an esophageal temperature probe was placed in the lower third of the esophagus, and a SpotOn sensor on the lateral forehead. Temperatures were recorded in pairs per 1 minute intervals. Temperatures were subjected to bias analysis with 0.5°C as the a priori established clinical significance cutoff.Results: Bland‐Altman analysis revealed the two methods differed on average 0.14°C (95% limits of agreement: −0.39 to 0.66), with 89.5% of the differences being under 0.5°C. No significant differences could be found between the two methods for the established 0.5°C cutoff. Linear regression analysis determined the following linear regression equation: 0.837x + 5.86 (R2 = 0.738). Lin's concordance correlation coefficient of 0.83 (95% CI: 0.81‐0.84). No complications were observed with the use of the SpotOn sensor.Conclusion: SpotOn revealed itself as accurate as an esophageal temperature probe when estimating central core temperatures under ideal conditions and over a narrow range of temperatures. No adverse effects were observed with the use of the SpotOn sensor.
21 June 2021 in Journal of Medical Internet Research
Background: Perioperative quantitative monitoring of neuromuscular function in patients receiving neuromuscular blockers has become internationally recognized as an absolute and core necessity in modern anesthesia care. Because of their kinetic nature, artifactual recordings of acceleromyography-based neuromuscular monitoring devices are not unusual. These generate a great deal of cynicism among anesthesiologists, constituting an obstacle toward their widespread adoption. Through outlier analysis techniques, monitoring devices can learn to detect and flag signal abnormalities. Outlier analysis (or anomaly detection) refers to the problem of finding patterns in data that do not conform to expected behavior. Objective: This study was motivated by the development of a smartphone app intended for neuromuscular monitoring based on combined accelerometric and angular hand movement data. During the paired comparison stage of this app against existing acceleromyography monitoring devices, it was noted that the results from both devices did not always concur. This study aims to engineer a set of features that enable the detection of outliers in the form of erroneous train-of-four (TOF) measurements from an acceleromyographic-based device. These features are tested for their potential in the detection of erroneous TOF measurements by developing an outlier detection algorithm. Methods: A data set encompassing 533 high-sensitivity TOF measurements from 35 patients was created based on a multicentric open label trial of a purpose-built accelero- and gyroscopic-based neuromuscular monitoring app. A basic set of features was extracted based on raw data while a second set of features was purpose engineered based on TOF pattern characteristics. Two cost-sensitive logistic regression (CSLR) models were deployed to evaluate the performance of these features. The final output of the developed models was a binary classification, indicating if a TOF measurement was an outlier or not. Results: A total of 7 basic features were extracted based on raw data, while another 8 features were engineered based on TOF pattern characteristics. The model training and testing were based on separate data sets: one with 319 measurements (18 outliers) and a second with 214 measurements (12 outliers). The F1 score (95% CI) was 0.86 (0.48-0.97) for the CSLR model with engineered features, significantly larger than the CSLR model with the basic features (0.29 [0.17-0.53]; P<.001). Conclusions: The set of engineered features and their corresponding incorporation in an outlier detection algorithm have the potential to increase overall neuromuscular monitoring data consistency. Integrating outlier flagging algorithms within neuromuscular monitors could potentially reduce overall acceleromyography-based reliability issues. Trial Registration: ClinicalTrials.gov NCT03605225; https://clinicaltrials.gov/ct2/show/NCT03605225
10 November 2022 in Journal of Clinical Monitoring and Computing