Ewoud J. Smit

Ewoud J. Smit

Auto-generated profile, based on publicly available information

Ewoud J. Smit

Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Radiology
Verified
Journal Article
Closed access
DGDagmar Grob
Dagmar Grob
ESEwoud Smit
Ewoud Smit
JPJip Prince
Jip Prince
JKJakob Kist
Jakob Kist
Lauran StögerLauran Stöger
Lauran Stöger
MBMonique Brink
Monique Brink
Subtraction CT shows comparable diagnostic performance to that of dual-energy CT in the detection of pulmonary embolism at similar radiation dose, without the need for dedicated hardware. BackgroundDual-energy CT iodine maps are used to detect pulmonary embolism (PE) with CT angiography but require dedicated hardware. Subtraction CT, a software-only solution, results in iodine maps ...

3 March 2025 in Medical Image Analysis
Verified
Journal Article
Open access
MGM.J.J. de Grauw
M.J.J. de Grauw
ESE.TH. Scholten
E.TH. Scholten
ESE.J. Smit
E.J. Smit
MRM.J.C.M. Rutten
M.J.C.M. Rutten
MPM. Prokop
M. Prokop
AHAlessa Hering
Alessa Hering
Size measurements of tumor manifestations on follow-up CT examinations are crucial for evaluating treatment outcomes in cancer patients. Efficient lesion segmentation can speed up these radiological workflows. While numerous benchmarks and challenges address lesion segmentation in specific organs like the liver, kidneys, and lungs, the larger variety of lesion types encountered in clinical practice demands a more universal approach. To address this gap, we introduced the ULS23 benchmark for 3D universal lesion segmentation in chest-abdomen-pelvis CT examinations. The ULS23 training dataset contains 38,693 lesions across this region, including challenging pancreatic, colon and bone lesions. For evaluation purposes, we curated a dataset comprising 775 lesions from 284 patients. Each of these lesions was identified as a target lesion in a clinical context, ensuring diversity and clinical relevance within this dataset. The ULS23 benchmark is publicly accessible at https://uls23.grand-challenge.org, enabling researchers worldwide to assess the performance of their segmentation methods. Furthermore, we have developed and publicly released our baseline semi-supervised 3D lesion segmentation model. This model achieved an average Dice coefficient of 0.703 ± 0.240 on the challenge test set. We invite ongoing submissions to advance the development of future ULS models.

9 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RMRashindra Manniesing
Rashindra Manniesing
MOMarcel T. H. Oei
Marcel T. H. Oei
LOLuuk J. Oostveen
Luuk J. Oostveen
JMJaime Melendez
Jaime Melendez
ESEwoud J. Smit
Ewoud J. Smit
BGBram van Ginneken
Bram van Ginneken
Modern Computed Tomography (CT) scanners are capable of acquiring contrast dynamics of the whole brain, adding functional to anatomical information. Soft tissue segmentation is important for subsequent applications such as tissue dependent perfusion analysis and automated detection and quantification of cerebral pathology. In this work a method is presented to automatically segment white matter (WM) and gray matter (GM) in contrast- enhanced 4D CT images of the brain. The method starts with intracranial segmentation via atlas registration, followed by a refinement using a geodesic active contour with dominating advection term steered by image gradient information, from a 3D temporal average image optimally weighted according to the exposures of the individual time points of the 4D CT acquisition. Next, three groups of voxel features are extracted: intensity, contextual, and temporal. These are used to segment WM and GM with a support vector machine. Performance was assessed using cross validation in a leave-one-patient-out manner on 22 patients. Dice coefficients were 0.81 ± 0.04 and 0.79 ± 0.05, 95% Hausdorff distances were 3.86 ± 1.43 and 3.07 ± 1.72 mm, for WM and GM, respectively. Thus, WM and GM segmentation is feasible in 4D CT with good accuracy.

12 June 2014 in Medical Physics
Verified
Journal Article
Open access
RBRieneke van Den Boom
Rieneke van Den Boom
RMRashindra Manniesing
Rashindra Manniesing
MOMarcel T. H. Oei
Marcel T. H. Oei
WWWillem-Jan van der Woude
Willem-Jan van der Woude
ESEwoud J. Smit
Ewoud J. Smit
MPMathias Prokop
Mathias Prokop
Optimizing CT brain perfusion protocols is a challenge because of the complex interaction between image acquisition, calculation of perfusion data, and patient hemodynamics. Several digital phantoms have been developed to avoid unnecessary patient exposure or suboptimum choice of parameters. The authors expand this idea by using realistic noise patterns and measured tissue attenuation curves representing patient-specific hemodynamics. The purpose of this work is to validate that this approach can realistically simulate mean perfusion values and noise on perfusion data for individual patients. The proposed 4D digital phantom consists of three major components: (1) a definition of the spatial structure of various brain tissues within the phantom, (2) measured tissue attenuation curves, and (3) measured noise patterns. Tissue attenuation curves were measured in patient data using regions of interest in gray matter and white matter. By assigning the tissue attenuation curves to the corresponding tissue curves within the phantom, patient-specific CTP acquisitions were retrospectively simulated. Noise patterns were acquired by repeatedly scanning an anthropomorphic skull phantom at various exposure settings. The authors selected 20 consecutive patients that were scanned for suspected ischemic stroke and constructed patient-specific 4D digital phantoms using the individual patients' hemodynamics. The perfusion maps of the patient data were compared with the digital phantom data. Agreement between phantom- and patient-derived data was determined for mean perfusion values and for standard deviation in de perfusion data using intraclass correlation coefficients (ICCs) and a linear fit. ICCs ranged between 0.92 and 0.99 for mean perfusion values. ICCs for the standard deviation in perfusion maps were between 0.86 and 0.93. Linear fitting yielded slope values between 0.90 and 1.06. A patient-specific 4D digital phantom allows for realistic simulation of mean values and standard deviation in perfusion data and makes it possible to retrospectively study how the interaction of patient hemodynamics and scan parameters affects CT perfusion values.

18 July 2022 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
KMKazuhiro Murayama
Kazuhiro Murayama
ESEwoud J. Smit
Ewoud J. Smit
MPMathias Prokop
Mathias Prokop
YIYoshihiro Ikeda
Yoshihiro Ikeda
KFKenji Fujii
Kenji Fujii
HTHiroshi Toyama
Hiroshi Toyama