Ziqi Yang

Ziqi Yang

Auto-generated profile, based on publicly available information

Ziqi Yang

Department of Metabolism, Digestion and Reproduction, Imperial College London, London, U.K.

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
RZRuiyang Zhang
Ruiyang Zhang
JCJunhong Chen
Junhong Chen
ZWZeyu Wang
Zeyu Wang
ZYZiqi Yang
Ziqi Yang
YRYunxiao Ren
Yunxiao Ren
BLBenny Lo
Benny Lo
In recent years, Robot-Assisted Minimally Invasive Surgery (RAMIS) has been widely adopted worldwide due to its high precision, improved ergonomics and intuitive control. With the advances in artificial intelligence and surgical robot technologies, it is anticipated that the cognitive load on the surgeons could be relieved with a higher level of autonomy on surgical robots as well as simultaneously improving the precision of surgical robots' operations, minimising the risk of human errors and leading to safer operations. However, much research is still focused on task autonomy due to the complexity of the operations, and the limited clinical data on robotic surgery in some specific scenarios. Therefore, recent research has widely used simulated surgery scenarios to collect data to train artificial intelligence (AI) models. In this paper, we propose a method as a step towards conditional autonomy for robotic appendectomy. To achieve conditional autonomy, demonstration data was collected from human operators performing the appendectomy in a simulated robotic scene. The robotic instrument movements and trajectories for performing the appendectomy were learned from the demonstrated data. Once the surgeon specifies the location of the appendix, the proposed framework can carry out the appendectomy autonomously by using the dynamic motion primitives (DMP) generated from the learned surgical movements. Through the extensive validations in a simulated environment and on the da Vinci Research Kit (dVRK), we have shown that the proposed method can carry out the appendectomy procedure semi-automatically. Based on five metrics, it shows that the framework can reduce the total task path length, completion time and appendix stump length while maintaining a high degree of similarity to the demonstrated trajectory. This work demonstrated the feasibility of conditional autonomy in robotic surgeries.

16 March 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
XZXuhui Zhou
Xuhui Zhou
ZYZiqi Yang
Ziqi Yang
YRYunxiao Ren
Yunxiao Ren
WBWeibang Bai
Weibang Bai
BLBenny Lo
Benny Lo
EYEric M. Yeatman
Eric M. Yeatman
The ubiquitous presence of three types of delay in robotic teleoperation systems, i.e. , computation delay, transmission delay, and mechanical delay, is the major factor of the system degradation. It is noticeable that the transmission latency over the communication network shows a periodic trend due to the network flux changing. Accordingly, in our previous work, a neural network-based open-loop approach named Bilateral Active Estimation Model (BAEM) was proposed to compensate for the upcoming transmission delay in a unilateral teleoperation system by sending predicted trajectories as commands. In this paper, a modified version of BAEM (m-BAEM) is proposed to compensate for all these three types of delay explicitly, and a real-time robotic teleoperation system based on Robot Operating System 2 (ROS 2) framework is built to evaluate the performance of the m-BAEM in constant and varying delay scenarios with both pre-defined and human-input trajectories. The results of pre-defined trajectories present the satisfactory performance of the m-BAEM even in the presence of transmission delay up to 1000 miliseconds with large variations. The main limitation of the m-BAEM is that it is yet unable to handle unknown trajectories.

9 October 2025 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
LTLibaihe Tian
Libaihe Tian
JZJinshi Zhao
Jinshi Zhao
ZYZiqi Yang
Ziqi Yang
VCVadzim Chalau
Vadzim Chalau
Burak TemelkuranBurak Temelkuran
Burak Temelkuran
Soft robotic instruments offer unique advantages for minimally invasive surgery (MIS), including safe tissue interaction and adaptability within confined anatomical spaces. However, achieving both miniaturization and functionality within a single device remains a significant engineering challenge. This work presents a monolithically fabricated, tendon-driven fiber robot produced via thermal drawing, integrating rigid polycarbonate (PC) and compliant Styrene-Ethylene-Butylene-Styren (SEBS) elastomer into a continuous, multi-lumen structure. The resulting platform enables remote steering of the fiber tip while supporting channels for additional diagnostic or therapeutic functions. Three purpose-specific fiber variants were developed and evaluated in anatomical phantoms: transvaginal tumor ablation requiring high-precision motion control, gastrointestinal optical diagnosis with spectroscopic sensing, and endovascular navigation with targeted liquid delivery. These demonstrations validate the robot’s precision, adaptability, and clinical relevance across multiple MIS scenarios. The proposed thermally drawn fiber offers a scalable approach for rapid prototyping and development of compact, multi-purpose medical devices.