10 March 2023 in IEEE Robotics and Automation Letters
In recent years, Robot-Assisted Minimally Invasive Surgery (RAMIS) has been widely adopted worldwide due to its high precision, improved ergonomics and intuitive control. With the advances in artificial intelligence and surgical robot technologies, it is anticipated that the cognitive load on the surgeons could be relieved with a higher level of autonomy on surgical robots as well as simultaneously improving the precision of surgical robots' operations, minimising the risk of human errors and leading to safer operations. However, much research is still focused on task autonomy due to the complexity of the operations, and the limited clinical data on robotic surgery in some specific scenarios. Therefore, recent research has widely used simulated surgery scenarios to collect data to train artificial intelligence (AI) models. In this paper, we propose a method as a step towards conditional autonomy for robotic appendectomy. To achieve conditional autonomy, demonstration data was collected from human operators performing the appendectomy in a simulated robotic scene. The robotic instrument movements and trajectories for performing the appendectomy were learned from the demonstrated data. Once the surgeon specifies the location of the appendix, the proposed framework can carry out the appendectomy autonomously by using the dynamic motion primitives (DMP) generated from the learned surgical movements. Through the extensive validations in a simulated environment and on the da Vinci Research Kit (dVRK), we have shown that the proposed method can carry out the appendectomy procedure semi-automatically. Based on five metrics, it shows that the framework can reduce the total task path length, completion time and appendix stump length while maintaining a high degree of similarity to the demonstrated trajectory. This work demonstrated the feasibility of conditional autonomy in robotic surgeries.
1 January 2026 in IEEE Transactions on Robotics
24 June 2026 in Journal of Innovative Optical Health Sciences
Endoscopic optical coherence tomography (OCT) integrates fiber-optic interferometry with miniaturized catheter-based probes to enable high-resolution, real-time, and minimally invasive volumetric imaging of internal tissue microstructures. Since its first demonstrations in the late 1990s, endoscopic OCT has evolved from early feasibility studies into a clinically valuable tool for tissue characterization and disease diagnosis. Over the past decade, the field has undergone a transformative shift toward high-performance systems, driven by advances in probe miniaturiza tion, ultrahigh-resolution optics, extended-depth-of-focus designs, multimodal integration, and intelligent control strategies, such as robotic actuation and novel steering methods. This review provides a comprehensive overview of recent advances in endoscopic OCT from both technological and translational perspectives. First, we review the evolution of the field and key enabling technologies, including miniaturized probe architectures, high-resolution and extended-depth-of focus imaging strategies, multimodal platforms, and intelligent or robotic systems. Second, we summarize established and emerging applications across major organ systems and several novel interventional settings. Finally, we discuss persistent technical challenges and outline promising future directions.
23 September 2026 in Science Robotics
Physiological motion in dynamic luminal organs, such as respiration-induced lung displacement, compromises the stability of tool-tissue interaction during telerobotic endoluminal imaging and interventions. However, existing devices for stabilizing the distal end of a catheter or endoscope face critical limitations: Rigid shape-locking mechanisms risk pressure-induced trauma, electrical hazard, and thermal injury, whereas balloon-based designs obstruct luminal patency. Moreover, they lack sufficient adjustable-diameter range for anatomies such as the bronchial tree. In this work, we present a reconfigurable helical brace that overcomes these challenges. Constructed of rotationally stacking tubular modules of asymmetric stiffness, the helical brace achieved up to almost 10 times diameter tunability (3.0 to 29.3 millimeters), enabling adaptive anchoring across diverse bronchial diameters. The established brace in a dynamic bronchus phantom reduced respiration-induced catheter displacement by about 96.0% while preserving more than 97.4% luminal flow conductance. Ex vivo and in vivo bronchial studies confirmed safety under prolonged radial loading, with no notable surface trauma or deep tissue injury observed. We demonstrate a helically braced telerobotic manipulator that can operate with submillimeter control accuracy in dynamic environments, enabling targeted transbronchial needle interventions in live porcine models, including drug delivery, bronchus puncture, and fluid aspiration. In addition, in vivo studies on porcine lungs showed that the brace-aided telerobotic catheter enhances the stability of optical coherence tomography imaging, effectively achieving respiratory motion-free conditions. This patency-preserving brace enhances stabilization without compromising physiological function and safety, ensuring accurate telerobotic operations in dynamic luminal environments.