He Yu

He Yu

Auto-generated profile, based on publicly available information

He Yu

Xihua University School of Energy and Power Engineering, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
LLLei Lei
Lei Lei
TWTao Wang
Tao Wang
BQBo Qiu
Bo Qiu
HYHe Yu
He Yu
YLYunqi Liu
Yunqi Liu
YDYuancheng Dong
Yuancheng Dong
Due to the complex structure of a double-suction pump's suction chamber, the flow in the pump's cavity is often ignored in numerical simulations because of difficulties in structured hexahedral meshing. However, the wear ring clearance interlinking the pump chamber leads the fluid at the impeller inlet directly to the impeller area. This significantly impacts the pump's internal flow field, so the influence of the clearance on the internal flow of a double-suction pump cannot be ignored. This paper develops four three-dimensional double-suction pump models with different wear ring clearances to investigate their influence on pump performance, and structured hexahedral meshes were used for all the computational domains. The clearances varied from 0.2 to 0.5 mm in 0.1 mm increments. The influences of the clearance on the energy loss, external characteristics, and internal flow field distribution of the pump were simulated via a verified computational fluid dynamics method. The results show that the wear ring leakage decreases with the flow rate and increases with wear ring clearance. The increase in backflow leads to an internal flow disorder inside the impeller, resulting in a decreased head and efficiency. Energy loss is mainly caused by increasing the turbulence entropy production with an increasing wear ring clearance. Also, the low-pressure region in the pump cavity expands to the volute with increasing clearance, and the impeller outlet pressure decreases. This study's research on wear ring clearance provides a reference for the design and application of double-suction centrifugal pumps.

1 November 2022 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
TWTao Wang
Tao Wang
HYHe Yu
He Yu
YFYujian Fang
Yujian Fang
RXRu Xiang
Ru Xiang
NKNeng Qi Kan
Neng Qi Kan
JYJing Yan
Jing Yan
Geometrical structures and operating performance of volutes used in centrifugal pumps are assessed in cross sections. By a volute, we mean the wetted part surrounding the impeller in a pump that converts the kinetic energy of water into potential energy. It is important to develop improved design principles and approaches for volutes to reduce hydraulic loss and increase the efficiency of pumps. However, when designing volutes, pump designers often neglect a key factor related to pump efficiency, namely, the energy loss due to the friction at the volute sidewall is directly proportional to the wetted perimeter of the cross section. In this paper, we show that the length of the wetted perimeter of the cross section is mathematically proportional to the friction loss in the volute. In addition, we present the design principles and calculation process to minimize the wetted perimeters of two kinds of cross section based on the velocity coefficient method using the same statistical data. The structures and shapes of the new cross sections are completely different from those of traditional volutes. Moreover, two different volutes with different cross sections are numerically investigated using a verified computational fluid dynamics technique. Both the head and the efficiency of the pump with the new volute are higher than those of a conventional pump under all working conditions. This paper provides a new design approach for the energy-saving volutes of centrifugal pumps.

1 June 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
LLLei Lei
Lei Lei
TWTao Wang
Tao Wang
BQBo Qiu
Bo Qiu
YLYunqi Liu
Yunqi Liu
HYHe Yu
He Yu
THTengfei Huang
Tengfei Huang
As an economical energy recovery device, pump as turbine (PAT) is widely used in micro-hydropower stations and the chemical industry. The inlet and outlet pipelines connected to the double-suction pump are on the same horizontal line. As the pipeline layout is very convenient, in some chemical industries, the way of residual pressure energy utilization is increasing using the double-suction pump as a turbine. Based on numerical simulation, experimental verification, and entropy generation theory, the energy loss rule of each flow component in the pump mode and turbine mode under different flow rates is compared and analyzed. The results show that when the double-suction pump is used as a turbine, the flow rate at the best efficiency point (BEP) in the turbine mode shifts to a large flow rate by 30.89% and the BEP efficiency decreases by 1.30%. In the pump mode and turbine mode, the main energy loss component is the impeller, and the turbulent entropy generation power and the wall entropy generation power are the main sources of energy loss. The energy loss in the suction chamber and impeller increases sharply, and the energy loss is primarily enhanced in the blade trailing edge and the tongue near due to the unsteady flow in the turbine mode. Due to the complex structure, the spiral suction chamber is not suitable for the flow direction of the fluid flow out of the impeller, and the flow state inside the impeller is negatively affected by the suction chamber in the turbine mode. This paper provides a theoretical basis for the design and application of double-suction centrifugal PAT.