Annie Pico

Annie Pico

Auto-generated profile, based on publicly available information

Annie Pico

University of Arizona, Phoenix, Arizona

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2024 in World Neurosurgery
Verified
Journal Article
Open access
JKJames Kelbert
James Kelbert
KNKristin Nosova
Kristin Nosova
AKAshley Kern
Ashley Kern
RRRachel Russell
Rachel Russell
APAnnie Pico
Annie Pico
RBRobert W. Bina
Robert W. Bina
Idiopathic normal pressure hydrocephalus is classically recognized by the triad of gait disturbance, cognitive dysfunction, and urinary incontinence. Since ventricular shunting may be affected by valve type, we conducted a meta-analysis to assess the relationship between valve characteristics and outcomes. English language studies that reported valve types, outcomes, and associated complications were included. Data were extracted and analyzed using R, version 4.3.2. Thirteen studies were included. With gravitational valves, meta-analysis yielded 0.04 [0.02, 0.07] for subdural effusions (SDEs), 0.00 [0.00, 0.00] for surgical SDEs, 0.06 [0.03, 0.09] for proximal revisions, and 0.06 [0.03, 0.09] for distal. With differential pressure valves (DPVs) with antisiphon control, meta-analysis showed an incidence of 0.10 [0.07, 0.13] for SDEs, 0.02 [0.01, 0.04] for surgical SDEs, 0.03 [0.01, 0.05] for proximal and 0.04 [0.02, 0.07] for distal revisions. With DPVs without antisiphon control, there was an incidence of 0.17 [0.11, 0.23] for SDEs, 0.11 [0.06, 0.19] for surgical SDEs, 0.00 [0.00, 0.02] for proximal shunt revisions, and 0.05 [0.02, 0.10] for distal shunt revisions. With flow regulated valves, there was an incidence of 0.05 [0.01, 0.12] for SDEs, 0.01 [0.00, 0.05] for surgical SDEs, 0.06 [0.02, 0.11] for proximal revisions, and 0.01 [0.00, 0.05] for distal. Gravitational valves and NPVs are associated with fewer SDEs while DPVs with and without ASDs are associated with more while there were no differences in proximal or distal revisions.

1 March 2024 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
EQEsteban Quiceno
Esteban Quiceno
AHAmna Hussein
Amna Hussein
APAnnie Pico
Annie Pico
EAEbtesam Abdulla
Ebtesam Abdulla
IBIsabel L. Bauer
Isabel L. Bauer
ABAli A. Baaj
Ali A. Baaj
OBJECTIVE: Selecting C2 versus C3 or C4 (i.e., C3/C4) as the rostral anchoring level in long-segment cervical fusions is a common clinical conundrum. The data regarding proximal failure in long constructs of the cervical spine is scarce. The objective of this study was to systematically review the published literature and perform a meta-analysis of the incidence for proximal adjacent-segment disease (ASD) in the context of long cervical fusions and cervicothoracic fusions ending in C2 versus those ending in the subaxial spine (C3 or C4). METHODS: Using the PRISMA guidelines, the authors performed a search of the PubMed/MEDLINE, Embase/Ovid, and Cochrane Central databases to identify all full-text articles in the English-language literature with the following inclusion criteria: 1) studies including patients with the upper instrumented vertebra (UIV) at C2 versus C3/C4; 2) patients undergoing ≥ 3-level posterior cervical fusion; and 3) indication for surgery of degenerative disc disease, cervical spondylotic myelopathy, or cervical deformity. Studies that were not published in the English language, case reports, review articles, letters to the editor, and meeting abstracts were excluded. A meta-analysis was conducted using a fixed-effects model when I2 values were below 70%. Conversely, when I2 values were equal to or greater than 70%, a random-effects model was used. A funnel plot was used to assess the presence of publication bias. RESULTS: Seven studies consisting of 1215 patients were included in the meta-analysis. There were 403 (32.8%) patients in the C2 UIV group and 812 (67.2%) patients in the C3/C4 UIV group. When the 7 studies were analyzed, the overall rate of reoperation was comparable between the C2 (9.2%) and C3/C4 (9.4%) UIV groups (p = 0.93) but the rate of surgical ASD due to proximal pathology was 1.2% and 3%, respectively (OR 0.36, 95% CI 0.15–0.86; p = 0.02). When comparing between groups, no statistical difference was found regarding the rate of reoperation due to distal pathology or surgical infection. CONCLUSIONS: Long-segment cervical or cervicothoracic constructs that anchor into C2 may have similar complication rates but lower revision rates for proximal ASD than constructs that anchor into the subaxial spine.

5 March 2024 in World Neurosurgery
Verified
Journal Article
Closed access
EQEsteban Quiceno
Esteban Quiceno
SSScott Seaman
Scott Seaman
AHAmna Hussein
Amna Hussein
NDNikhil Dholaria
Nikhil Dholaria
APAnnie Pico
Annie Pico
ABAli Baaj
Ali Baaj

28 September 2024 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
GBG. Barbagli
G. Barbagli
DSD. Soto-Rubio
D. Soto-Rubio
NPN. Pacheco-Barrios
N. Pacheco-Barrios
CLC. Li
C. Li
AAAl- Arfaj
Al- Arfaj
ABA.A. Baaj
A.A. Baaj

13 March 2025 in Journal of Spine Practice (JSP)
Verified
Journal Article
Open access
PDF file
NDNikhil Dholaria
Nikhil Dholaria
JGJuan P Giraldo
Juan P Giraldo
SDSohail Daulat
Sohail Daulat
JKJames Kelbert
James Kelbert
VSVick S. Sahni
Vick S. Sahni
ABAli A. Baaj
Ali A. Baaj
Purpose Even though plate and screw designs in anterior cervical discectomy and fusion (ACDF) have evolved to improve fusion stability and enhance patient outcomes, some argue that pre-tapping remained the best option. The purpose of this study is to evaluate the outcomes and complications of self-drilling, self-tapping screws and evaluate their efficacy in maintaining instrumentation position in plated ACDFs. Methods In this retrospective case series, patients who underwent ACDF with plating and selfdrilling, self-tapping screws from February 2021 to May 2023 were consecutively included. Demographic, radiographic, intraoperative, and postoperative data were collected. Odds ratios (ORs) were also utilized to determine factors associated with abnormal C2-C7 Cobb angles and C2-C7 sagittal vertical axes (SVAs) postoperatively. Results A total of 50 patients (26M, 24F, mean age: 56.7 ± 10.4) were included. At the final postoperative radiographic follow-up (251.1 ± 226.5 days), the C2-C7 Cobb angle increased by 21.03%, with the C2-C7 SVA increasing by 3.25%. OR assessment found an association with the American Society of Anesthesiologists (ASA) physical status classification score of ≥ 3 and abnormal postoperative C2-C7 SVA (5.667, 95% CI: 1.067 to 30.086, p=0.042). Longer operative times (≥91.5 minutes) were less likely to be associated with abnormal postoperative C2-C7 Cobb angles when compared to shorter operative times (0.175, 95% CI: 0.032 to 0.952, p=0.044). No fixation system complications or evidence of radiographic or clinical pseudoarthrosis were noted. Conclusion Patients undergoing ACDF with self-drilling, self-tapping screws had excellent postoperative outcomes and no evidence of instrumentation complications, including pseudoarthrosis. This case series demonstrates the safety of ACDF with this screw design. However, future studies should include a larger cohort of patients to provide more accurate guidelines and recommendations.

22 July 2024 in Journal of Spine Practice (JSP)
Verified
Journal Article
Open access
PDF file
AMAlexandros Moniakis
Alexandros Moniakis
NPNiels Pacheco
Niels Pacheco
EQEsteban Quiceno
Esteban Quiceno
AHAmna Hussein
Amna Hussein
APAnnie Pico
Annie Pico
ABAli Baaj
Ali Baaj
Objective: The advantages of minimally invasive spine surgery (MISS) in lumbar degenerative diseases have been well described (less tissue damage, shorter hospital stay, better results in pain assessment). One aspect that has not yet been studied enough is the usage of a post-operative drain in MISS. The aim of this study was to determine whether drainage in MISS is necessary or not and what advantages or disadvantages its use offers. Materials - Methods: We conducted a systematic review of the published literature, searching articles published on Pubmed and Embasse until December 1st 2022, regarding MISS in the lumbar region and post-operative drain usage. Our inclusion criteria were original articles written in English and articles using minimally invasive techniques (usage of tubular retractors along with an endoscope or microscope, paramedian incision, percutaneous screw placement). 42 articles were assessed, and after careful examination and duplication exclusion, 26 research papers were included. Usage, type and duration of postoperative drainage, length of hospital stay, ambulation time and complications were extracted, and relevant results were pooled. Results: The majority of the included articles (80.7 %) reported using a negative-pressure post-operative drain tube. Drains were removed either 48 hours after surgery or when the drainage volume was less than 50ml/24h. Hospital stays and time to ambulation were shorter in cases where drainage was not used. There was no difference in complications between cases where drainage was used and those that it was not. Conclusion: The rationale behind post-operative drainage in MISS is to protect from surgical site infections and hematoma creation. Based on our study there is no evidence to support this hypothesis. On the contrary, our results suggest that the drawbacks of using a drain (pain, discomfort, anxiety, inconvenience of mobilisation, prolongation of hospitalisation) outweigh the advantages, thus making the routine use of postoperative drainage in MISS unnecessary.