Alexandros Moniakis

Dr. Alexandros Moniakis


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2024 in World Neurosurgery
Verified
Journal Article
Closed access
EQEsteban Quiceno
Esteban Quiceno
SSScott Seaman
Scott Seaman
AHAmna Hussein
Amna Hussein
NDNikhil Dholaria
Nikhil Dholaria
APAnnie Pico
Annie Pico
ABAli Baaj
Ali Baaj

Verified
Journal Article
Open access
PDF file
LFLuca Fumagalli
Luca Fumagalli
AMAlexandros Moniakis
Alexandros Moniakis
APAlberto Pagnamenta
Alberto Pagnamenta
ACAndrea Cardia
Andrea Cardia
ICIvan Cabrilo
Ivan Cabrilo
Background/Objectives: The potential advantages of robotic assistance in spinal procedures are a growing area of interest, and patient perception plays a key role in its broader acceptance. However, public perception of robotic surgery in spinal operations remains unexplored. This study aims to assess the general public’s perceptions, expectations, and concerns regarding robot-assisted spine surgery. Methods: In the fall of 2024, a questionnaire was distributed to attendees at a public open day at the Neurocenter of Southern Switzerland, where the Globus ExcelsiusGPS™ spine surgery robot was demonstrated live on a mannequin. The 15-item questionnaire assessed demographic data, prior knowledge of medical robots, mental representations of surgical robots, expectations, and emotions after witnessing the demonstration. Data were analyzed using descriptive statistics, chi-square, Wilcoxon, McNemar tests, and logistic regression analysis. Results: A total of 109 questionnaires were collected. Most participants were female (64.4%) and had no direct experience with spinal pathology (79.8%). While 87.2% were aware of robotic surgery in general, only 65.1% specifically knew about its use in spine surgery. After witnessing the live demonstration, 81.9% felt reassured by the robot′s presence in surgery, compared to 61.3% before the demonstration (p = 0.007). Preference for robot-assisted surgery increased from 50.5% to 64.5% (p < 0.001). Notably, individuals with back-related issues showed greater confidence in the robot’s capabilities (p = 0.032). Conclusions: The general public perceives robotic spine surgery positively, viewing it as faster, more precise, and capable of performing tasks not readily performed by humans. The study highlights the importance of live demonstrations in enhancing trust and acceptance of robotic systems. Its findings have economic implications, as patients may be more likely to choose hospitals offering robot-assisted spine surgery. However, it is essential to also acknowledge alternative methods, such as computer-assisted navigation, which has demonstrated efficacy in spine surgery.

1 March 2024 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
EQEsteban Quiceno
Esteban Quiceno
AHAmna Hussein
Amna Hussein
APAnnie Pico
Annie Pico
EAEbtesam Abdulla
Ebtesam Abdulla
IBIsabel L. Bauer
Isabel L. Bauer
ABAli A. Baaj
Ali A. Baaj
OBJECTIVE: Selecting C2 versus C3 or C4 (i.e., C3/C4) as the rostral anchoring level in long-segment cervical fusions is a common clinical conundrum. The data regarding proximal failure in long constructs of the cervical spine is scarce. The objective of this study was to systematically review the published literature and perform a meta-analysis of the incidence for proximal adjacent-segment disease (ASD) in the context of long cervical fusions and cervicothoracic fusions ending in C2 versus those ending in the subaxial spine (C3 or C4). METHODS: Using the PRISMA guidelines, the authors performed a search of the PubMed/MEDLINE, Embase/Ovid, and Cochrane Central databases to identify all full-text articles in the English-language literature with the following inclusion criteria: 1) studies including patients with the upper instrumented vertebra (UIV) at C2 versus C3/C4; 2) patients undergoing ≥ 3-level posterior cervical fusion; and 3) indication for surgery of degenerative disc disease, cervical spondylotic myelopathy, or cervical deformity. Studies that were not published in the English language, case reports, review articles, letters to the editor, and meeting abstracts were excluded. A meta-analysis was conducted using a fixed-effects model when I2 values were below 70%. Conversely, when I2 values were equal to or greater than 70%, a random-effects model was used. A funnel plot was used to assess the presence of publication bias. RESULTS: Seven studies consisting of 1215 patients were included in the meta-analysis. There were 403 (32.8%) patients in the C2 UIV group and 812 (67.2%) patients in the C3/C4 UIV group. When the 7 studies were analyzed, the overall rate of reoperation was comparable between the C2 (9.2%) and C3/C4 (9.4%) UIV groups (p = 0.93) but the rate of surgical ASD due to proximal pathology was 1.2% and 3%, respectively (OR 0.36, 95% CI 0.15–0.86; p = 0.02). When comparing between groups, no statistical difference was found regarding the rate of reoperation due to distal pathology or surgical infection. CONCLUSIONS: Long-segment cervical or cervicothoracic constructs that anchor into C2 may have similar complication rates but lower revision rates for proximal ASD than constructs that anchor into the subaxial spine.

1 June 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
ECEleonora Case
Eleonora Case
SBSabrina Bettoni
Sabrina Bettoni
RMRossana Maria Mosca
Rossana Maria Mosca
FMFabio Mauri
Fabio Mauri
VRVladimir Reyes
Vladimir Reyes
DMDavide Milani
Davide Milani
Background: Acute neurosurgical emergencies during pregnancy are rare but pose significant challenges due to the need for simultaneous management of two interdependent patients. Evidence remains limited, and standardized multidisciplinary protocols are lacking. Case Presentation: A 38-year-old woman at 32 + 4 weeks of gestation presented with acute left hemiparesis secondary to right capsulo-insular intracerebral hemorrhage with mass effect. Following initial conservative management, neurological deterioration and hematoma expansion necessitated emergency craniotomy. A structured multidisciplinary approach was implemented involving neurosurgery, anesthesiology, obstetrics, and neonatology, with predefined roles, continuous intraoperative fetal monitoring, and readiness for emergency cesarean delivery. Anesthetic management balanced maternal neuroprotection with preservation of uteroplacental perfusion. Surgery was completed without fetal compromise. The patient demonstrated neurological improvement and was transferred on postoperative day 13. Elective cesarean delivery was performed at 36 weeks. Conclusions: This case illustrates that emergency neurosurgery during pregnancy may be feasible in selected settings when supported by structured multidisciplinary coordination. Key practical elements included continuous fetal monitoring, predefined team roles, and immediate availability of obstetric and neonatal support. In this individual case, these components facilitated intraoperative decision-making and were associated with favorable maternal and fetal outcomes; however, their individual contribution cannot be determined from a single clinical experience. Further evidence is needed to assess the applicability of this approach across different clinical scenarios.

13 November 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAlexandros Moniakis
Alexandros Moniakis
AGAntonella Maria Giardina
Antonella Maria Giardina
IZIsmail Zaed
Ismail Zaed
MMMarco Morandi
Marco Morandi
ACAndrea Cardia
Andrea Cardia
DMDavide Milani
Davide Milani
Intraoperative ultrasound (ioUS) provides real-time imaging during cranial surgery and may be particularly useful when the reliability of conventional neuronavigation is reduced by brain shift, tissue distortion, or registration challenges. Cottonoid patties have previously been described as echogenic markers for intraoperative orientation, but their use has remained limited. In this technical note and case series, we describe a simple technique combining cottonoids with ioUS to provide a dynamic intraoperative reference during tumor resection. By exploiting the intrinsic hyperechogenicity of cottonoids and their readily identifiable movement during gentle manipulation, the technique was used to confirm surgical trajectories, support depth perception, and assist with spatial orientation throughout the procedure. We report a consecutive series of 12 patients with intracranial tumors in different anatomical locations and surgical positions, with particular emphasis on posterior fossa and occipital lesions. Rather than introducing a novel concept, the present Technical Note extends previous proof-of-concept experience by describing the practical transferability of cottonoid-guided ioUS to an independent consecutive adult cohort and by detailing its repeated use throughout the operative workflow, from initial trajectory confirmation to resection-cavity assessment. Trajectory confirmation was estimated by the operating surgeon to require less than 30 s in all cases, and no complications attributable to the technique were observed. Gross-total resection, assessed by postoperative magnetic resonance imaging, was achieved in all patients. The series also provides practical experience with posterior fossa and prone-position procedures, settings that remain comparatively underrepresented in the published literature. Our experience suggests that cottonoid-guided ioUS is a feasible, inexpensive, and practical adjunct to conventional neuronavigation, providing a dynamic reference that reflects current intraoperative anatomy.

22 July 2024 in Journal of Spine Practice (JSP)
Verified
Journal Article
Open access
PDF file
AMAlexandros Moniakis
Alexandros Moniakis
NPNiels Pacheco
Niels Pacheco
EQEsteban Quiceno
Esteban Quiceno
AHAmna Hussein
Amna Hussein
APAnnie Pico
Annie Pico
ABAli Baaj
Ali Baaj
Objective: The advantages of minimally invasive spine surgery (MISS) in lumbar degenerative diseases have been well described (less tissue damage, shorter hospital stay, better results in pain assessment). One aspect that has not yet been studied enough is the usage of a post-operative drain in MISS. The aim of this study was to determine whether drainage in MISS is necessary or not and what advantages or disadvantages its use offers. Materials - Methods: We conducted a systematic review of the published literature, searching articles published on Pubmed and Embasse until December 1st 2022, regarding MISS in the lumbar region and post-operative drain usage. Our inclusion criteria were original articles written in English and articles using minimally invasive techniques (usage of tubular retractors along with an endoscope or microscope, paramedian incision, percutaneous screw placement). 42 articles were assessed, and after careful examination and duplication exclusion, 26 research papers were included. Usage, type and duration of postoperative drainage, length of hospital stay, ambulation time and complications were extracted, and relevant results were pooled. Results: The majority of the included articles (80.7 %) reported using a negative-pressure post-operative drain tube. Drains were removed either 48 hours after surgery or when the drainage volume was less than 50ml/24h. Hospital stays and time to ambulation were shorter in cases where drainage was not used. There was no difference in complications between cases where drainage was used and those that it was not. Conclusion: The rationale behind post-operative drainage in MISS is to protect from surgical site infections and hematoma creation. Based on our study there is no evidence to support this hypothesis. On the contrary, our results suggest that the drawbacks of using a drain (pain, discomfort, anxiety, inconvenience of mobilisation, prolongation of hospitalisation) outweigh the advantages, thus making the routine use of postoperative drainage in MISS unnecessary.