Tolulope O. Odimayomi

Tolulope O. Odimayomi

Auto-generated profile, based on publicly available information

Tolulope O. Odimayomi

Via Department of Civil and Environmental Engineering

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Building and Environment
Verified
Journal Article
Closed access
MSMaryam Salehi
Maryam Salehi
TOTolu Odimayomi
Tolu Odimayomi
KRKyungyeon Ra
Kyungyeon Ra
CLChristian Ley
Christian Ley
RJRyan Julien
Ryan Julien
AWAndrew Whelton
Andrew Whelton

21 April 2022 in Journal of Cleaner Production
Verified
Journal Article
Open access
YNYoorae Noh
Yoorae Noh
TOTolulope Odimayomi
Tolulope Odimayomi
SSSeyedeh Mahboobeh Teimouri Sendesi
Seyedeh Mahboobeh Teimouri Sendesi
JYJeffrey P. Youngblood
Jeffrey P. Youngblood
AWAndrew J. Whelton
Andrew J. Whelton

21 August 2020 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
KRKyungyeon Ra
Kyungyeon Ra
TOTolulope Odimayomi
Tolulope Odimayomi
CLChristian Ley
Christian Ley
Tiong Gim AwTiong Gim Aw
Tiong Gim Aw
JRJoan B. Rose
Joan B. Rose
AWAndrew J. Whelton
Andrew J. Whelton
Water safety was investigated at a school certified as a green building.

2 April 2024 in ACS ES&T Water
Verified
Journal Article
Open access
KWKory Wait
Kory Wait
SRSiddhartha Roy
Siddhartha Roy
AKAdrienne Katner
Adrienne Katner
APAmy Pruden
Amy Pruden
JPJeannie Purchase
Jeannie Purchase
MEMarc Edwards
Marc Edwards

3 January 2025 in ACS ES&T Water
Verified
Journal Article
Open access
SBSarah Busch
Sarah Busch
TOTolulope O. Odimayomi
Tolulope O. Odimayomi
WRWilliam J. Rhoads
William J. Rhoads
APAmy Pruden
Amy Pruden
MEMarc Edwards
Marc Edwards
A building plumbing rig experiment simultaneously examined how water temperature (cold/hot lines), influent disinfectant residual (0-1 mg/L chloramine), flow rate (0.5-2.2 gpm), and water retention time (WRT) of 0-17-days impacted water quality at the point of use. In cold water lines with no disinfectant, WRT was a key driver of bacterial growth, with total cell counts (TCC) in the water increasing by up to 20× relative to influent water at 6.7-days WRT. A chloramine residual in cold influent water suppressed the maximum TCC by about 50%, even after the residual was no longer measurable. When the water heater set point was warm (40 °C) with minimal or 1 mg/L Cl2 chloramine, the majority of microbial growth occurred in the tank (WRT = 3 days). However, at a heater set point of 60 °C with 1 mg/L as Cl2, growth was completely repressed in the tank, shifting growth to the distal pipes. Legionella spp. gene copies measured in cold bulk water increased with WRT, but not flow velocity. In hot water biofilms, Legionella spp. gene copies were highest at low WRT and high flow velocities. Mycobacterium spp. gene copies in hot water biofilms escalated after chloramines were introduced and were positively correlated to water velocity.

19 September 2023 in Environmental Science and Ecotechnology
Verified
Journal Article
Open access
KRKyungyeon Ra
Kyungyeon Ra
CPCaitlin Proctor
Caitlin Proctor
CLChristian Ley
Christian Ley
DADanielle Angert
Danielle Angert
YNYoorae Noh
Yoorae Noh
AWAndrew J. Whelton
Andrew J. Whelton
A reduction in building occupancy can lead to stagnant water in plumbing, and the potential consequences for water quality have gained increasing attention. To investigate this, a study was conducted during the COVID-19 pandemic, focusing on water quality in four institutional buildings. Two of these buildings were old (>58 years) and large (>19,000 m2), while the other two were new (>13 years) and small (<11,000 m2). The study revealed significant decreases in water usage in the small buildings, whereas usage remained unchanged in the large buildings. Initial analysis found that residual chlorine was rarely detectable in cold/drinking water samples. Furthermore, the pH, dissolved oxygen, total organic carbon, and total cell count levels in the first draw of cold water samples were similar across all buildings. However, the ranges of heavy metal concentrations in large buildings were greater than observed in small buildings. Copper (Cu), lead (Pb), and manganese (Mn) sporadically exceeded drinking water limits at cold water fixtures, with maximum concentrations of 2.7 mg Cu L−1, 45.4 μg Pb L−1, 1.9 mg Mn L−1. Flushing the plumbing for 5 min resulted in detectable residual at fixtures in three buildings, but even after 125 min of flushing in largest and oldest building, no residual chlorine was detected at the fixture closest to the building's point of entry. During the pandemic, the building owner conducted fixture flushing, where one to a few fixtures were operated per visit in buildings with hundreds of fixtures and multiple floors. However, further research is needed to understand the fundamental processes that control faucet water quality from the service line to the faucet. In the absence of this knowledge, building owners should create and use as-built drawings to develop flushing plans and conduct periodic water testing.