Michael D. Jensen

Michael D. Jensen

Auto-generated profile, based on publicly available information

Michael D. Jensen

Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7, Canada

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in Radiotherapy and Oncology
Verified
Journal Article
Open access
KTKundan Thind
Kundan Thind
MJMichael D. Jensen
Michael D. Jensen
EHElaine Hegarty
Elaine Hegarty
ACAlbert P. Chen
Albert P. Chen
HLHeeseung Lim
Heeseung Lim
GSGiles E. Santyr
Giles E. Santyr
Radiation Pneumonitis (RP) limits radiotherapy. Detection of early metabolic changes in the lungs associated with RP may provide an opportunity to adjust treatment before substantial toxicities occur. In this work, regional lactate-to-pyruvate signal ratio (lac/pyr) was quantified in rat lungs and heart following administration of hyperpolarized (13)C-pyruvate magnetic resonance imaging (MRI) at day 5, 10, 15 and 25-post conformal radiotherapy. These results were also compared to histology and blood analyses. The lower right lungs of 12 Sprague Dawley rats were irradiated in 2 fractions with a total dose of 18.5 Gy using a modified micro-CT system. Regional lactate and pyruvate data were acquired from three irradiated and three age-matched healthy rats at each time point on days 5, 10, 15 and 25-post radiotherapy. Arterial blood was collected from each animal prior to the (13)C-pyruvate injection and was analyzed for blood lactate concentration and arterial oxygen concentration (paO₂). Macrophage count was computed from the histology of all rat lungs. A significant increase in lac/pyr was observed in both right and left lungs of the irradiated cohort compared to the healthy cohort for all time points. No increase in lac/pyr was observed in the hearts of the irradiated cohort compared to the hearts of the healthy cohorts. Blood lactate concentration and paO2 did not show a significant change between the irradiated and the healthy cohorts. Macrophage count in both right and left lungs was elevated for the irradiated cohort compared to the healthy cohort. Metabolic changes associated with RP may be mapped as early as five days post conformal radiotherapy. Over the small sample size in each cohort, elevated macrophage count, consistent with early phase of inflammation was highly correlated to increases in lac/pyr in both the irradiated and unirradiated lungs. Further experiments with larger sample size may improve the confidence of this finding.

1 June 2016 in Translational Oncology
Verified
Journal Article
Open access
DMDonna H. Murrell
Donna H. Murrell
NZNiloufar Zarghami
Niloufar Zarghami
MJMichael D. Jensen
Michael D. Jensen
ACAnn F. Chambers
Ann F. Chambers
EWEugene Wong
Eugene Wong
PFPaula Foster
Paula Foster
The incidence of brain metastasis due to breast cancer is increasing, and prognosis is poor. Treatment is challenging because the blood-brain barrier (BBB) limits efficacy of systemic therapies. In this work, we develop a clinically relevant whole brain radiotherapy (WBRT) plan to investigate the impact of radiation on brain metastasis development and BBB permeability in a murine model. We hypothesize that radiotherapy will decrease tumor burden and increase tumor permeability, which could offer a mechanism to increase drug uptake in brain metastases. Contrast-enhanced magnetic resonance imaging (MRI) and high-resolution anatomical MRI were used to evaluate BBB integrity associated with brain metastases due to breast cancer in the MDA-MB-231-BR-HER2 model during their natural development. Novel image-guided microirradiation technology was employed to develop WBRT treatment plans and to investigate if this altered brain metastatic growth or permeability. Histology and immunohistochemistry were performed on whole brain slices corresponding with MRI to validate and further investigate radiological findings. Herein, we show successful implementation of microirradiation technology that can deliver WBRT to small animals. We further report that WBRT following diagnosis of brain metastasis can mitigate, but not eliminate, tumor growth in the MDA-MB-231-BR-HER2 model. Moreover, radiotherapy did not impact BBB permeability associated with metastases. Clinically relevant WBRT is not curative when delivered after MRI-detectable tumors have developed in this model. A dose of 20 Gy in 2 fractions was not sufficient to increase tumor permeability such that it could be used as a method to increase systemic drug uptake in brain metastasis.

12 July 2013 in Medical Physics
Verified
Journal Article
Open access
PDF file
MJMichael D. Jensen
Michael D. Jensen
WHWilliam Thomas Hrinivich
William Thomas Hrinivich
JJJongho A. Jung
Jongho A. Jung
DHDavid Holdsworth
David Holdsworth
MDMaria Drangova
Maria Drangova
EWEugene Wong
Eugene Wong
Purpose: To design, construct, and commission a set of computer‐controlled motorized jaws for a micro‐CT/RT system to perform conformal image‐guided small animal radiotherapy. Methods: The authors designed and evaluated a system of custom‐built motorized orthogonal jaws, which allows the delivery of off‐axis rectangular fields on a GE eXplore CT 120 preclinical imaging system. The jaws in the x direction are independently driven, while the y‐direction jaws are symmetric. All motors have backup encoders, verifying jaw positions. Mechanical performance of the jaws was characterized. Square beam profiles ranging from 2 × 2 to 60 × 60 mm2 were measured using EBT2 film in the center of a 70 × 70 × 22 mm3 solid water block. Similarly, absolute depth dose was measured in a solid water and EBT2 film stack 50 × 50 × 50 mm3. A calibrated Farmer ion chamber in a 70 × 70 × 20 mm3 solid water block was used to measure the output of three field sizes: 50 × 50, 40 × 40, and 30 × 30 mm2. Elliptical target plans were delivered to films to assess overall system performance. Respiratory‐gated treatment was implemented on the system and initially proved using a simple sinusoidal motion phantom. All films were scanned on a flatbed scanner (Epson 1000XL) and converted to dose using a fitted calibration curve. A Monte Carlo beam model of the micro‐CT with the jaws has been created using BEAMnrc for comparison with the measurements. An example image‐guided partial lung irradiation in a rat is demonstrated. Results: The averaged random error of positioning each jaw is less than 0.1 mm. Relative output factors measured with the ion chamber agree with Monte Carlo simulations within 2%. Beam profiles and absolute depth dose curves measured from the films agree with simulations within measurement uncertainty. Respiratory‐gated treatments applied to a phantom moving with a peak‐to‐peak amplitude of 5 mm showed improved beam penumbra (80%–20%) from 3.9 to 0.8mm. Conclusions: A set of computer‐controlled motorized jaws for a micro‐CT/RT system were constructed with position reliably better than a tenth of a millimeter. The hardware system is ready for image‐guided conformal radiotherapy for small animals with capability of respiratory‐gated delivery.

14 November 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
DMDonna H. Murrell
Donna H. Murrell
NZNiloufar Zarghami
Niloufar Zarghami
MJMichael D. Jensen
Michael D. Jensen
FDFiona Dickson
Fiona Dickson
ACAnn F. Chambers
Ann F. Chambers
PFPaula J. Foster
Paula J. Foster

25 August 2014 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
GSGiles Santyr
Giles Santyr
MFMatthew Fox
Matthew Fox
KTKundan Thind
Kundan Thind
EHElaine Hegarty
Elaine Hegarty
AOAlexei Ouriadov
Alexei Ouriadov
EWEugene Wong
Eugene Wong

27 February 2012 in Medical Physics
Verified
Journal Article
Closed access
AAAdy Abdellatif
Ady Abdellatif
JCJeff Craig
Jeff Craig
MJMichael Jensen
Michael Jensen
MMMatt Mulligan
Matt Mulligan
HMHomeira Mosalaei
Homeira Mosalaei
EWEugene Wong
Eugene Wong