In this letter, we report on the response of surface plasmon resonance (SPR, reflectance versus incident angle) and transverse magneto-optic Kerr effect (T-MOKE) versus incident angle) in two different magneto-optic-plasmonic (MOP) configurations: Ti/Au/Co/Au (Configuration A) and Ti/Ag/Co/Au (Configuration B) at the excitation wavelength of 780 nm in air. Configuration A includes a 35 nm Au layer and Configuration B includes a 35 nm Ag layer. Both configurations consist of a thin (4 or 8 nm) Co magneto-optic layer and showed an enhancement of the T-MOKE signal over the SPR signal. Configuration B showed higher SPR and T-MOKE responses over Configuration A, possibly due to the low loss and higher plasmonic properties of Ag over Au. The T-MOKE based sensor shows improvements in quality factor by over two times compared to that of SPR. The magneto-optic SPR sensitivity of the sensor obtained shows an improvement by three times over the SPR sensitivity, and this can be further improved by suitably modifying the configuration. These results are of importance to the development of enhanced MOP/plasmonic sensors.
Here we experimentally demonstrate the topological Faraday effect—the polarization rotation caused by the orbital angular momentum of light. It is found that the Faraday effect of the optical vortex beam passing through a transparent magnetic dielectric film differs from the Faraday effect for a plane wave. The additional contribution to the Faraday rotation depends linearly on the topological charge and radial number of the beam. The effect is explained in terms of the optical spin-orbit interaction. These findings underline the importance of using the optical vortex beams for studies of magnetically ordered materials.
Ferrimagnetic rare-earth substituted metal alloys GdFeCo were shown to exhibit the phenomenon of all-optical magnetization switching via femtosecond laser pulses. All-optical magnetization switching has been comprehensively investigated in out-of-plane magnetized GdFeCo films; however, the films with the in-plane magnetic anisotropy have not yet been studied in detail. We report experimental observations of the magnetization switching of in-plane magnetized GdFeCo films by means of the femtosecond laser pulses in the presence of a small magnetic field of about 40 µT. The switching effect has a threshold both in the applied magnetic field and in the light intensity.
We propose an all-dielectric magneto-photonic crystal with a hybrid magneto-optical response that allows for the simultaneous measurements of the surface and bulk refractive index of the analyzed substance. The approach is based on two different spectral features of the magneto-optical response corresponding to the resonances in p- and s-polarizations of the incident light. Angular spectra of p-polarized light have a step-like behavior near the total internal reflection angle which position is sensitive to the bulk refractive index. S-polarized light excites the TE-polarized optical Tamm surface mode localized in a submicron region near the photonic crystal surface and is sensitive to the refractive index of the near-surface analyte. We propose to measure a hybrid magneto-optical intensity modulation of p-polarized light obtained by switching the magnetic field between the transverse and polar configurations. The transversal component of the external magnetic field is responsible for the magneto-optical resonance near total internal reflection conditions, and the polar component reveals the resonance of the Tamm surface mode. Therefore, both surface- and bulk-associated features are present in the magneto-optical spectra of the p-polarized light.
1 December 2008 in Bulletin of the Russian Academy of Sciences: Physics
The diffusion of water vapor into porous polymer adsorbent MN-200 has been investigated by diode laser spectroscopy with a time resolution of 0.1 s. The cascade character of diffusion, caused presumably by the fractality of the porous matrix space, is established by decomposition analysis. The collisionless (Knudsen) mode of water motion in pores, in which water molecules can be sorted according to their spin states, is selected.
22 December 2023 in IEEE Transactions on Biomedical Engineering
In the current study we propose a magneto-optical system for registration and analysis of magnetic nano- and microparticles magnetic relaxation. The core of our system is the novel compact magnetometer based on an yttrium-iron garnet film and working at room temperature. The sensor demonstrates sensitivity of 35 $\mathsf{pT/\sqrt{{Hz}}}$ at 79 Hz and recovery time less than 100 µs, which allows to register quite fast magnetic relaxations of a low amplitude. All these facts make the system feasible for usage in biological magnetorelaxometry and theranostics. Statistical processing of the relaxation curves allowed us to estimate both amplitudes and relaxation times for various biocompatible magnetic particles at the amount of 100 µg in the test tubes experiments. The system has a great potential of further development for usage in the areas of targeted drug delivery, hyperthermia, magnetic imaging. Being comparatively cheap, the system potentially is of a great interest in the fields of biomedicine and nanomedicine.