Xinming Liu

Xinming Liu

Auto-generated profile, based on publicly available information

Xinming Liu

U.T.M.D Anderson Cancer Center Houston TX USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Radiology
Verified
Journal Article
Closed access
CJCorey T. Jensen
Corey T. Jensen
SGShiva Gupta
Shiva Gupta
MSMohammed Saleh
Mohammed Saleh
XLXinming Liu
Xinming Liu
VWVincenzo Wong
Vincenzo Wong
NWNicolaus A. Wagner-Bartak
Nicolaus A. Wagner-Bartak
At 65% reduced radiation dose, deep learning image reconstruction improved CT image quality with robust denoising but had inferior lesion characterization and inferior lesion detection for small li... Background Assessment of liver lesions is constrained as CT radiation doses are lowered; evidence suggests deep learning reconstructions mitigate such effects. Purpose To evaluate liver metastases ...

19 March 2018 in Nanomedicine
Verified
Journal Article
Open access
TZTian Zhou
Tian Zhou
ZLZhiyi Lin
Zhiyi Lin
PPPavan Puligujja
Pavan Puligujja
DPDiana Palandri
Diana Palandri
JHJames Hilaire
James Hilaire
HGHoward Eliot Gendelman
Howard Eliot Gendelman
Aim: While the therapeutic potential for current long-acting (LA) antiretroviral therapy (ART) is undeniable, ligand-decorated nanoformulated LA-ART could optimize drug delivery to viral reservoirs. The development of decorated ART hinges, however, on formulation processes and manufacture efficiencies. To this end, we compared manufacture and purification techniques for ligand-decorated antiretroviral drug nanocrystals. Materials & methods: Ligand-decorated nanoparticle manufacturing was tested using folic acid (FA) nanoformulated cabotegravir. Results: Direct manufacturing of FA-cabotegravir resulted in stable particles with high drug loading and monocyte–macrophage targeting. A one step ‘direct’ scheme proved superior over differential centrifugation or tangential flow filtration facilitating particle stability and preparation simplicity and efficiency. Conclusion: Direct manufacturing of FA nanoparticles provides a path toward large-scale clinical grade manufacturing of cell-targeted LA-ART. Lay abstract Folic acid (FA) decoration on the surface of nanocrystals can be achieved by mixing FA conjugated poloxamer 407 (FA-P407) and native P407 in varied ratios followed by size reduction by homogenization and differential centrifugation or tangential flow filtration to remove excess unbound polymers. The optimized manufacturing scheme is by direct homogenization with predetermined quantity of FA conjugated P407. Direct manufacturing method yields stable homogenous nanoparticles with high drug loading.

3 May 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
DCDianna D. Cody
Dianna D. Cody
CDChad M. Dillon
Chad M. Dillon
TFTyler S. Fisher
Tyler S. Fisher
XLXinming Liu
Xinming Liu
MMMichael F. McNitt‐Gray
Michael F. McNitt‐Gray
VPVikas Patel
Vikas Patel
The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: (a) Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. (b) Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.

14 December 2010 in Medical Physics
Verified
Journal Article
Open access
XLXinming Liu
Xinming Liu
CSChris C. Shaw
Chris C. Shaw
CLChao‐Jen Lai
Chao‐Jen Lai
TWTianpeng Wang
Tianpeng Wang
Purpose: To investigate and compare the scatter rejection properties and low‐contrast performance of the scan equalization digital radiography (SEDR) technique to the slot‐scan and conventional full‐field digital radiography techniques for chest imaging.Methods: A prototype SEDR system was designed and constructed with an a‐Se flat‐panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot‐scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24‐segment beam width modulator was developed to regulate x‐ray exposures regionally and compensate for the low x‐ray flux in heavily attenuating regions. To measure the scatter‐to‐primary ratios (SPRs), a 2 mm thick lead plate with a 2‐D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2‐D array of aluminum beads (3 mm in diameter) was used as the low‐contrast objects to measure the contrast ratios (CRs) and contrast‐to‐noise ratios (CNRs) for evaluating the low‐contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot‐scan images and full‐field images acquired with and without antiscatter grid.Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full‐field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot‐scan, and full‐field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full‐field imaging by 259%, 279%, and 145% for SEDR, slot‐scan, and full‐field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full‐field imaging by 201% for SEDR as compared to 133% for the slot‐scan technique and 14% for the antiscatter grid method.Conclusions: Both SEDR and slot‐scan techniques outperformed the antiscatter grid method used in standard full‐field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot‐scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low‐contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.