Thomas W. Buggey

Thomas W. Buggey

Auto-generated profile, based on publicly available information

Thomas W. Buggey

Centre for Electronic Imaging, The Open University, Walton Hall, Milton Keynes, U.K.

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
CTCharles Townsend-Rose
Charles Townsend-Rose
TBThomas Buggey
Thomas Buggey
JIJames Ivory
James Ivory
KSKonstantin Stefanov
Konstantin Stefanov
LJLawrence Jones
Lawrence Jones
TPThibaut Prod’homme
Thibaut Prod’homme
CIS221-X is a prototype complementary metal-oxide-semiconductor (CMOS) image sensor, optimized for soft x-ray astronomy and developed for the proposed ESA Transient High Energy Sky and Early Universe Surveyor (THESEUS) mission. The sensor features 40 μm pitch square pixels built on a 35 μm thick, high-resistivity epitaxial silicon that is fully depleted by reverse substrate bias. Backside illumination processing has been used to achieve high x-ray quantum efficiency, and an optical light-blocking filter has been applied to mitigate the influence of stray light. A comprehensive electro-optical characterization of CIS221-X has been completed. The median readout noise is 3.3 e − RMS with 90% of pixels reporting a value <3.6 e − RMS. At −40 ° C, the dark current is 12.4 ± 0.06 e − / pixel / s. The pixel photo-response is linear to within 1% for 0.3 to 5 keV photons (82 to 1370 e − ) with 80 % quantum efficiency. With the exception of dark current, these results either meet or outperform the requirements for the THESEUS mission, strongly supporting the consideration of CMOS technology for soft x-ray astronomy.

29 August 2022
Verified
Conference Paper
Closed access
PDF file
KSKonstantin D. Stefanov
Konstantin D. Stefanov
CTCharles Townsend-Rose
Charles Townsend-Rose
TBThomas W. Buggey
Thomas W. Buggey
JIJames Ivory
James Ivory
OHOliver Hetherington
Oliver Hetherington
MSMatthew Soman
Matthew Soman
A monolithic CMOS image sensor based on the pinned photodiode (PPD) and optimized for X-ray imaging in the 300 eV to 5 keV energy range is described. Featuring 40 μm square pixels and 40 μm thick, high resistivity epitaxial silicon, the sensor is fully depleted by reverse substrate bias. Backside illumination (BSI) processing has been used to achieve high X-ray QE, and a dedicated pixel design has been developed for low image lag and high conversion gain. The sensor, called CIS221-X, is manufactured in a 180 nm CMOS process and has three different 512×128-pixel arrays on 40 μm pitch, as well as a 2048×512 array of 10 μm pixels. CIS221-X also features per-column 12-bit ADCs, digital readout via four highspeed LVDS outputs, and can be read out at 45 frames per second. CIS221-X achieves readout noise of 2.6 e- RMS and full width at half maximum (FWHM) at the Mn-Kα 5.9 keV characteristic X-ray line of 153 eV at -40 °C. This paper presents the characterization results of the first backside illuminated CIS221-X, including X-ray response and readout noise. The newly developed sensor and the technology underpinning it is intended for diverse applications, including Xray astronomy, synchrotron, and X-ray free electron laser light sources.

1 April 2022 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Closed access
PDF file
TBThomas W. Buggey
Thomas W. Buggey
MSMatthew R. Soman
Matthew R. Soman
DHDavid J. Hall
David J. Hall
NBNathan Bush
Nathan Bush
SPSteven Parsons
Steven Parsons
AHAndrew D. Holland
Andrew D. Holland
Charge-coupled devices (CCDs) have been the detector of choice for large-scale space missions for many years. Although dominant in this field, the charge transfer performance of the technology degrades over time due to the radiation-harsh space environment. Charge transfer performance can be optimized; however, it is often time consuming and expensive due to the many operating modes of the CCD, especially considering the ever-increasing needs of detector performance. A technique that uses measurements of the trap landscape present in a CCD to predict changes in charge transfer inefficiency as a function of different experimental variables is presented and developed. Using this technique, it is possible to focus experimental lab testing on key device parameters, potentially saving many months of laboratory effort. Due to the generality of the method, it can be used to optimize the charge transfer performance of any CCD and, as such, has many uses across a wide range of fields and space missions. Future CCD variants that will be used in potential space missions (EMCCD and p-channel CCDs) can use this technique to provide feedback of the key device performance to the wider mission consortium before devices are available for experimental testing.

1 July 2024 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
MHMichael Hubbard
Michael Hubbard
TBThomas W. Buggey
Thomas W. Buggey
DHDavid J. Hall
David J. Hall
CFCharly Feldman
Charly Feldman
JKJonathan Keelan
Jonathan Keelan
AHAndrew D. Holland
Andrew D. Holland
Space observatories utilizing micro pore optics (MPOs) have been used and are planned for several future X-ray astronomy space missions. The optical systems are designed to facilitate the focusing of incoming photons onto the focal plane of telescopes. Unfortunately, as well as having a small solid angle “open” to the sky, MPOs also have the unintentional effect of focusing high-energy particles from the space radiation environment. This causes additional radiation damage to mission-critical imaging sensors with solar energetic particles being particularly focusable. Typically, processes such as sectoral analysis are used to estimate the predicted dose to components, which is a ray tracing approach, and does not include focusing effects. We investigated focused dose estimation techniques for MPOs using Monte Carlo (MC) simulations. The focused dose contribution was compared with the unfocused contribution for the Solar wind Magnetosphere Ionosphere Link Explorer mission. The unfocused dose estimates were calculated using a traditional sectoral shielding analysis. The Monte Carlo-focused dose simulations enabled dose mapping over the image sensor to be analyzed. This revealed a relatively uniform dose across the device with some focusing artifacts present. The simulations also showed that the total ionizing dose and total non-ionizing dose decreased with depth into the sensor from the entrance window. This is key when considering that charge is often stored at varying depths in imaging devices across different technologies, for example, in front or back illuminated devices.

1 July 2024 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
CTCharles Townsend-Rose
Charles Townsend-Rose
TBThomas W. Buggey
Thomas W. Buggey
JIJames M. Ivory
James M. Ivory
IDImane Dazzazi
Imane Dazzazi
KSKonstantin Stefanov
Konstantin Stefanov
DHDavid J. Hall
David J. Hall
CIS221-X is a prototype monolithic complementary metal-oxide-semiconductor (CMOS) image sensor, optimized for soft X-ray astronomy and developed for the proposed European Space Agency Transient High Energy Sky and Early Universe Surveyor (THESEUS) mission. One significant advantage of CMOS technology is its resistance to radiation damage. To assess this resistance, three backside-illuminated CIS221-X detectors have been irradiated with 10 MeV protons using the MC40 Cyclotron Facility at the University of Birmingham, United Kingdom. Each detector received 1/2, 1, and 2 THESEUS end-of-life proton fluences (6.65×108 p+/cm2). One had already been exposed to ionizing radiation [up to 59.04 krad total ionizing dose (TID)] during a previous radiation campaign. Using unirradiated readout electronics, the electro-optical performance of each device has been measured before and after proton irradiation. No significant change was observed in the readout noise and image lag. An increase in mean dark current was recorded, as was an increase in the number of hot pixels. The degradation of CIS221-X performance due to non-ionizing radiation effects is similar to that of comparable CMOS image sensors and has been attributed to an increase in the number of bulk silicon defects.

27 August 2024
Verified
Conference Paper
Closed access
PDF file
SPSteve Parsons
Steve Parsons
DHDavid J. Hall
David J. Hall
OHOliver Hetherington
Oliver Hetherington
TBThomas W. Buggey
Thomas W. Buggey
TATimothy Arnold
Timothy Arnold
AHAndrew D. Holland
Andrew D. Holland
The SMILE mission, a collaborative effort between the European Space Agency and the Chinese Academy of Sciences, seeks to enhance our comprehension of the interplay between solar phenomena and the Earth's magnetosphere-ionosphere system on a global scale. Among its instrumental arsenal is the Soft X-ray Imager (SXI), designed to capture photons generated within the 200eV to 2000eV energy spectrum through the solar wind charge exchange process. This imaging tool employs two large CCD370s, each with 4510 x 4510 18μm pitch pixels, as its focal plane. SMILE will orbit Earth in an elliptical trajectory, traversing the radiation belts approximately every 52 hours. Over the course of its anticipated 3-year mission, the CCDs onboard will endure progressive deterioration from the persistent presence of trapped and solar protons. To gauge the extent of this damage and its effect on the devices' functionality, a sequence of proton radiation campaigns is underway. The final cryogenic irradiation campaign has now been completed using a fully functioning engineering model of the SXI CCD370s that will be used in flight and irradiating up to the expected end of life total non-ionising dose. The results show that the measured parallel charge transfer inefficiency (pCTI) varies with temperature both before and after irradiation, however the trend changes from decreasing with temperature to increasing. This is thought to be due to a change in the dominant effective trap species. The impact of multiple charge injection lines and 6x6 binned frame transfer is also assessed and shows that between -130 to -100°C the pCTI, when both measures are utilized, is independent of temperature. This suggests potential for more flexible thermal controls in future missions that use similar devices.