1 October 2023 in Journal of Astronomical Telescopes, Instruments, and Systems
CIS221-X is a prototype complementary metal-oxide-semiconductor (CMOS) image sensor, optimized for soft x-ray astronomy and developed for the proposed ESA Transient High Energy Sky and Early Universe Surveyor (THESEUS) mission. The sensor features 40 μm pitch square pixels built on a 35 μm thick, high-resistivity epitaxial silicon that is fully depleted by reverse substrate bias. Backside illumination processing has been used to achieve high x-ray quantum efficiency, and an optical light-blocking filter has been applied to mitigate the influence of stray light. A comprehensive electro-optical characterization of CIS221-X has been completed. The median readout noise is 3.3 e − RMS with 90% of pixels reporting a value <3.6 e − RMS. At −40 ° C, the dark current is 12.4 ± 0.06 e − / pixel / s. The pixel photo-response is linear to within 1% for 0.3 to 5 keV photons (82 to 1370 e − ) with 80 % quantum efficiency. With the exception of dark current, these results either meet or outperform the requirements for the THESEUS mission, strongly supporting the consideration of CMOS technology for soft x-ray astronomy.
1 April 2022 in Journal of Astronomical Telescopes, Instruments, and Systems
Charge-coupled devices (CCDs) have been the detector of choice for large-scale space missions for many years. Although dominant in this field, the charge transfer performance of the technology degrades over time due to the radiation-harsh space environment. Charge transfer performance can be optimized; however, it is often time consuming and expensive due to the many operating modes of the CCD, especially considering the ever-increasing needs of detector performance. A technique that uses measurements of the trap landscape present in a CCD to predict changes in charge transfer inefficiency as a function of different experimental variables is presented and developed. Using this technique, it is possible to focus experimental lab testing on key device parameters, potentially saving many months of laboratory effort. Due to the generality of the method, it can be used to optimize the charge transfer performance of any CCD and, as such, has many uses across a wide range of fields and space missions. Future CCD variants that will be used in potential space missions (EMCCD and p-channel CCDs) can use this technique to provide feedback of the key device performance to the wider mission consortium before devices are available for experimental testing.
1 July 2024 in Journal of Astronomical Telescopes, Instruments, and Systems
Space observatories utilizing micro pore optics (MPOs) have been used and are planned for several future X-ray astronomy space missions. The optical systems are designed to facilitate the focusing of incoming photons onto the focal plane of telescopes. Unfortunately, as well as having a small solid angle “open” to the sky, MPOs also have the unintentional effect of focusing high-energy particles from the space radiation environment. This causes additional radiation damage to mission-critical imaging sensors with solar energetic particles being particularly focusable. Typically, processes such as sectoral analysis are used to estimate the predicted dose to components, which is a ray tracing approach, and does not include focusing effects. We investigated focused dose estimation techniques for MPOs using Monte Carlo (MC) simulations. The focused dose contribution was compared with the unfocused contribution for the Solar wind Magnetosphere Ionosphere Link Explorer mission. The unfocused dose estimates were calculated using a traditional sectoral shielding analysis. The Monte Carlo-focused dose simulations enabled dose mapping over the image sensor to be analyzed. This revealed a relatively uniform dose across the device with some focusing artifacts present. The simulations also showed that the total ionizing dose and total non-ionizing dose decreased with depth into the sensor from the entrance window. This is key when considering that charge is often stored at varying depths in imaging devices across different technologies, for example, in front or back illuminated devices.
1 July 2024 in Journal of Astronomical Telescopes, Instruments, and Systems
CIS221-X is a prototype monolithic complementary metal-oxide-semiconductor (CMOS) image sensor, optimized for soft X-ray astronomy and developed for the proposed European Space Agency Transient High Energy Sky and Early Universe Surveyor (THESEUS) mission. One significant advantage of CMOS technology is its resistance to radiation damage. To assess this resistance, three backside-illuminated CIS221-X detectors have been irradiated with 10 MeV protons using the MC40 Cyclotron Facility at the University of Birmingham, United Kingdom. Each detector received 1/2, 1, and 2 THESEUS end-of-life proton fluences (6.65×108 p+/cm2). One had already been exposed to ionizing radiation [up to 59.04 krad total ionizing dose (TID)] during a previous radiation campaign. Using unirradiated readout electronics, the electro-optical performance of each device has been measured before and after proton irradiation. No significant change was observed in the readout noise and image lag. An increase in mean dark current was recorded, as was an increase in the number of hot pixels. The degradation of CIS221-X performance due to non-ionizing radiation effects is similar to that of comparable CMOS image sensors and has been attributed to an increase in the number of bulk silicon defects.