Rodrigo de Castro Albuquerque

Rodrigo de Castro Albuquerque

Auto-generated profile, based on publicly available information

Rodrigo de Castro Albuquerque

Professor, Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Brazil

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2002 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
RGRicardo Santiago Gomez
Ricardo Santiago Gomez
RAR. De Castro Albuquerque
R. De Castro Albuquerque
RDR. A. Dutra
R. A. Dutra
WVW. A. Vasconcellos
W. A. Vasconcellos
DRD. A. Reis
D. A. Reis
MGM. V. Gomez
M. V. Gomez

1 January 2025 in Brazilian Dental Journal
Verified
Journal Article
Open access
MGMarcelo Giannini
Marcelo Giannini
ECEduardo F. de Castro
Eduardo F. de Castro
BSBeatriz Ometto Sahadi
Beatriz Ometto Sahadi
RARodrigo de Castro Albuquerque
Rodrigo de Castro Albuquerque
FRFred Rueggeberg
Fred Rueggeberg
This study evaluated how short curing times affect monomer conversion and microhardness of a bulk-fill composite. Two light-curing units (LCUs) were used: a laser LCU (Monet, AMD Lasers) and a multi-peak LED LCU (PowerCure, Ivoclar Vivadent). A bulk-fill composite (Tetric PowerFill, Ivoclar) was cured for 1, 2, or 3 seconds with the laser, and for 3 or 20 seconds with the LED. Monomer conversion was measured via real-time FTIR at the bottom of 4-mm composite cylinders. Microhardness was assessed at 100µm, 1mm, 2mm, 3mm, and 390µm depths. Spectral irradiance, radiant emittance, and radiant exposure of each LCU were recorded using a calibrated system. Data were analyzed using ANOVA and Tukey’s test (α = 0.05). Radiant exposures for the laser LCU were 2.5, 5.0, and 7.5 J/cm² for 1, 2, and 3 seconds, respectively. The LED LCU delivered 9.3 J/cm² (3 s) and 22.3 J/cm² (20 s). Monomer conversion at 4 mm increased with more prolonged exposure for both LCUs. The LED LCU at 20 seconds showed significantly higher conversion than at 3 seconds. Microhardness decreased with depth, regardless of curing method or duration. Monomer conversion at 4 mm was higher with increased curing time, correlating with radiant exposure. Only the 20-second LED exposure provided a bottom-to-top microhardness ratio of 0.84, indicating sufficient curing at depth.

17 April 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
TRThales Lara Rabelo
Thales Lara Rabelo
AAAlberto Antunes
Alberto Antunes
DPDaniel Sousa Pardini
Daniel Sousa Pardini
RARodrigo de Castro Albuquerque
Rodrigo de Castro Albuquerque
CACarolina Bosso André
Carolina Bosso André
PSPaulo Isaias Seraidarian
Paulo Isaias Seraidarian
This in vitro study aimed to analyze the fracture strength and failure pattern of flared bovine roots restored with different intraradicular fiber posts and core materials, without a ferrule. To conduct this study fifty bovine incisor roots were treated endodontically, and divided into five groups (n=10), according to the following fiber post techniques and core materials: prefabricated fiberglass post and full-body bulk-fill resin composite (PF-BF); prefabricated fiberglass post and dual function resin cement (PF-RC); direct anatomic post and full-body bulk-fill resin composite (AP-BF); CAD-CAM integrated fiberglass post-and-core (CAD-PC); and adjustable fiberglass post and full-body bulk-fill resin composite (AD-BF). Intraradicular fiber posts were cemented with dual functional resin cement (Allcem Core, FGM), restored with CAD-CAM composite crowns (Brava, FGM), and subjected to loading. The data were analyzed by generalized linear models (p <0.05). It was revealed that AP-BF presented lower fracture strength values compared with PF-RC (p=0.006) and AD-BF (p=0.013). Fractures involving the apical third only in CAD-PC. PF-RC presented only failure patterns involving the core restoration or were limited to the cervical third. PF-RC and AD-BF presented higher failure patterns limited to the core restoration, compared with other groups (60% and 50% respectively). Fractures involving the middle third were observed in the PF-BF, AP-BF, CAD-PC, and AD-BF groups. In conclusion, most of the intraradicular fiber post techniques used, and different core materials presented similar fracture strength values. CAD-CAM integrated fiberglass post-and-core presented more fractures involving the middle and apical thirds than the other groups.

19 May 2026 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
RARodrigo de Castro Albuquerque
Rodrigo de Castro Albuquerque
RNRodrigo Keigo Nakagawa
Rodrigo Keigo Nakagawa
LMLucas Moreira Maia
Lucas Moreira Maia
RSRodrigo Richard da Silveira
Rodrigo Richard da Silveira
NSNelson Renato Franca Alves Silva
Nelson Renato Franca Alves Silva

21 July 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
AMAdriana Vieira Martins
Adriana Vieira Martins
RARodrigo de Castro Albuquerque
Rodrigo de Castro Albuquerque
LMLucas Moreira Maia
Lucas Moreira Maia
HOHans Hatner Araujo Oliveira
Hans Hatner Araujo Oliveira
RNRodrigo Keigo Nakagawa
Rodrigo Keigo Nakagawa
RSRodrigo Silveira
Rodrigo Silveira
The aim of this study is to illustrate and discuss the fundamentals of a well-succeeded and minimally invasive technique of surgical reintervention for installing implant in the reduced area of the alveolus, affected by agenesis, and traumatized by an unsuccessful intervention. Materials and methods: A 27-year-old patient sought dental care and her main cause was the great dissatisfaction with the aesthetic sequelae in the region of the right upper lateral incisor, in addition to the uncertainty regarding the predictability of a new unitary implant. Imaging exams showed trauma in the middle and apical region of the canine root surface. The dimensions of the edentulous area varied between 4.6 and 5.52 mm. A small diameter implant (BLT 2.9mm SC, Loxim SLActive® 12 mm, TiZr - Straumann Dental Implant System) was planned and installed, in addition to a subepithelial connective graft. Results: The results achieved allowed to restore the desired function and aesthetics, with excellence, low morbidity, in addition to a predictability favored by the benefits related to small diameter implants. Conclusions: The concept of minimally invasive dentistry is becoming an effective surgical approach and, although these implants present a higher risk for fracture than do large-diameter implants, implant fractures are rarely observed.

1 January 2025 in RGO - Revista Gaúcha de Odontologia
Verified
Journal Article
Open access
LSLuana Dias da Silva
Luana Dias da Silva
NSNelson Renato França Alves Silva
Nelson Renato França Alves Silva
RSRodrigo Silveira
Rodrigo Silveira
RARodrigo de Castro Albuquerque
Rodrigo de Castro Albuquerque
AMAdriana Vieira Martins
Adriana Vieira Martins
Aesthetic restorative materials, especially dental ceramics, are one of the most requested materials in oral rehabilitation. The success of dental ceramics, in general, is dependent on factors such as their physical properties, the manufacturing process of indirect work and the clinical procedures included in their adjustments and cementation. Understanding the conditions related to such materials and the professional’s attitude towards the handling of ceramic works contributes to their proper performance. It is worth mentioning the issue related to the oral environment, a condition that opposes the success of such materials, as it is an environment subjected to loads of varying intensity and direction. A humid environment, constantly subjected to thermal changes, changes in pH, and where longevity of such materials is expected to be considered friable. This paper aims to review the aspects related to the evolution and performance of current ceramic systems. At the same time, it proposes a reflection of the clinical and laboratory maneuvers commonly involved in the construction, preparation and adjustment of pure ceramic prosthetic pieces.