Gerard Amorós-Figueras

Gerard Amorós-Figueras

Auto-generated profile, based on publicly available information

Gerard Amorós-Figueras

Department of Cardiology, Hospital de la Santa Creu I Sant Pau, Institut de Recerca Sant Pau (IR Sant Pau), CIBERCV, Universitat Autònoma de Barcelona

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2012 in Applied Physics Letters
Verified
Journal Article
Closed access
FÖF. Öisjöen
F. Öisjöen
JSJustin F. Schneiderman
Justin F. Schneiderman
GFG. A. Figueras
G. A. Figueras
MCM. L. Chukharkin
M. L. Chukharkin
AKA. Kalabukhov
A. Kalabukhov
DWD. Winkler
D. Winkler
We have performed single- and two-channel high transition temperature (high-Tc) superconducting quantum interference device (SQUID) magnetoencephalography (MEG) recordings of spontaneous brain activity in two healthy human subjects. We demonstrate modulation of two well-known brain rhythms: the occipital alpha rhythm and the mu rhythm found in the motor cortex. We further show that despite higher noise-levels compared to their low-Tc counterparts, high-Tc SQUIDs can be used to detect and record physiologically relevant brain rhythms with comparable signal-to-noise ratios. These results indicate the utility of high-Tc technology in MEG recordings of a broader range of brain activity.

1 October 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
EJEsther Jorge
Esther Jorge
MCMaría C. Campos
María C. Campos
EMElad Maor
Elad Maor
AIAntoni Ivorra
Antoni Ivorra
Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.

1 September 2023 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
SCSergi Casabella-Ramon
Sergi Casabella-Ramon
ZMZoraida Moreno-Weidmann
Zoraida Moreno-Weidmann
AIAntoni Ivorra
Antoni Ivorra
JGJose M Guerra
Jose M Guerra
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)| max . Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different ( P <0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.

1 April 2018 in Heart Rhythm
Verified
Journal Article
Open access
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
EJEsther Jorge
Esther Jorge
CAConcepción Alonso-Martin
Concepción Alonso-Martin
DTDaniel Traver
Daniel Traver
MBMaria Ballesta
Maria Ballesta
JCJuan Cinca
Juan Cinca
BACKGROUND Measurement of myocardial electrical impedance can allow recognition of infarct scar and is theoretically not influenced by changes in cardiac activation sequence, but this is not known. OBJECTIVES The objectives of this study were to evaluate the ability of endocardial electrical impedance measurements to recognize areas of infarct scar and to assess the stability of the impedance data under changes in cardiac activation sequence. METHODS One-month-old myocardial infarction confirmed by cardiac magnetic resonance imaging was induced in 5 pigs submitted to coronary artery catheter balloon occlusion. Electroanatomic data and local electrical impedance (magnitude, phase angle, and amplitude of the systolic-diastolic impedance curve) were recorded at multiple endocardial sites in sinus rhythm and during right ventricular pacing. By merging the cardiac magnetic resonance and electroanatomic data, we classified each impedance measurement site either as healthy (bipolar amplitude >= 1.5 mV and maximum pixel intensity <40%) or scar (bipolar amplitude = 40%). RESULTS A total of 137 endocardial sites were studied. Compared to healthy tissue, areas of infarct scar showed 37.4% reduction in impedance magnitude (P<.001) and 21.5% decrease in phase angle (P<.001). The best predictive ability to detect infarct scar was achieved by the combination of the 4 impedance parameters (area under the receiver operating characteristic curve 0.96; 95% confidence interval 0.92-1.00). In contrast to voltage mapping, right ventricular pacing did not significantly modify the impedance data. CONCLUSION Endocardial catheter measurement of electrical impedance can identify infarct scar regions, and in contrast to voltage mapping, the impedance data are not affected by changes in cardiac activation sequence.

31 August 2016 in Frontiers in Physiology
Verified
Journal Article
Open access
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
EJEsther Jorge
Esther Jorge
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
RBRamón Bragós
Ramón Bragós
JRJavier Rosell-Ferrer
Javier Rosell-Ferrer
JCJuan Cinca
Juan Cinca
Myocardial electrical impedance is a biophysical property of the heart that is influenced by the intrinsic structural characteristics of the tissue. Therefore, the structural derangements elicited in a chronic myocardial infarction should cause specific changes in the local systolic-diastolic myocardial impedance, but this is not known. This study aimed to characterize the local changes of systolic-diastolic myocardial impedance in a healed myocardial infarction model. Six pigs were submitted to 150 min of left anterior descending coronary artery occlusion followed by reperfusion. Four weeks later, myocardial impedance spectroscopy (1-1000 kHz) was measured at different infarction sites. The electrocardiogram, left ventricular (LV) pressure, LV dP/dt, and aortic blood flow were also recorded. A total of 59 LV tissue samples were obtained and histopathological studies were performed to quantify the percentage of fibrosis. Samples were categorized as normal myocardium (50%). Resistivity of normal myocardium depicted phasic changes during the cardiac cycle and its amplitude markedly decreased in dense scar (18±2Ω·cm vs 10±1Ω·cm, at 41 kHz; P<0.001, respectively). The mean phasic resistivity decreased progressively from normal to heterogeneous and dense scar regions (285±10 Ω·cm, 225±25Ω·cm, and 162±6Ω·cm, at 41 kHz; P<0.001 respectively). Moreover, myocardial resistivity and phase angle correlated significantly with the degree of local fibrosis (resistivity: r=0.86 at 1 kHz, P<0.001; phase angle: r=0.84 at 41 kHz, P<0.001). Myocardial infarcted regions with greater fibrotic content show lower mean impedance values and more depressed systolic-diastolic dynamic impedance changes.

1 February 2016 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Open access
PDF file
EJEsther Jorge
Esther Jorge
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
RBRamón Bragós
Ramón Bragós
JRJavier Rosell-Ferrer
Javier Rosell-Ferrer
JCJuan Cinca
Juan Cinca
Myocardial electrical impedance is influenced by the mechanical activity of the heart. Therefore, the ischemia-induced mechanical dysfunction may cause specific changes in the systolic-diastolic pattern of myocardial impedance, but this is not known. This study aimed to analyze the phasic changes of myocardial resistivity in normal and ischemic conditions. Myocardial resistivity was measured continuously during the cardiac cycle using 26 different simultaneous excitation frequencies (1 kHz–1 MHz) in 7 anesthetized open-chest pigs. Animals were submitted to 30 min regional ischemia by acute left anterior descending coronary artery occlusion. The electrocardiogram, left ventricular (LV) pressure, LV dP/dt, and aortic blood flow were recorded simultaneously. Baseline myocardial resistivity depicted a phasic pattern during the cardiac cycle with higher values at the preejection period (4.19 ± 1.09% increase above the mean, P < 0.001) and lower values during relaxation phase (5.01 ± 0.85% below the mean, P < 0.001). Acute coronary occlusion induced two effects on the phasic resistivity curve: 1) a prompt (5 min ischemia) holosystolic resistivity rise leading to a bell-shaped waveform and to a reduction of the area under the LV pressure-impedance curve (1,427 ± 335 vs. 757 ± 266 Ω·cm·mmHg, P < 0.01, 41 kHz) and 2) a subsequent (5–10 min ischemia) progressive mean resistivity rise (325 ± 23 vs. 438 ± 37 Ω·cm at 30 min, P < 0.01, 1 kHz). The structural and mechanical myocardial dysfunction induced by acute coronary occlusion can be recognized by specific changes in the systolic-diastolic myocardial resistivity curve. Therefore these changes may become a new indicator (surrogate) of evolving acute myocardial ischemia.