1 October 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
EJEsther Jorge
Esther Jorge
MCMaría C. Campos
María C. Campos
EMElad Maor
Elad Maor
AIAntoni Ivorra
Antoni Ivorra
Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.

1 September 2023 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
GAGerard Amorós-Figueras
Gerard Amorós-Figueras
SCSergi Casabella-Ramon
Sergi Casabella-Ramon
ZMZoraida Moreno-Weidmann
Zoraida Moreno-Weidmann
AIAntoni Ivorra
Antoni Ivorra
JGJose M Guerra
Jose M Guerra
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)| max . Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different ( P <0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.

1 October 2015 in Bioelectrochemistry
Verified
Journal Article
Open access
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
AAAntoine Azan
Antoine Azan
ILIsabelle Leray
Isabelle Leray
JRJavier Rosell-Ferrer
Javier Rosell-Ferrer
RBRamon Bragós
Ramon Bragós
LMLluis M. Mir
Lluis M. Mir
In this study, electrical impedance spectroscopy measurements are performed during electroporation of monolayers of differentiated myotubes. The time resolution of the system (1 spectrum/ms) enable 860 full spectra (21 frequencies from 5 kHz to 1.3 MHz) to be acquired during the time gap between consecutive pulses (interpulse) of a classical electroporation treatment (8 pulses, 100 μs, 1 Hz). Additionally, the characteristics of the custom microelectrode assembly used allow the experiments to be performed directly in situ in standard 24 multi-well plates. The impedance response dynamics are studied for three different electric field intensities (400, 800 and 1200 V/cm). The multifrequency information, analysed with the Cole model, reveals a short-term impedance recovery after each pulse in accordance with the fast resealing of the cell membrane, and a long-term impedance decay over the complete treatment in accordance with an accumulated effect pulse after pulse. The analysis shows differences between the lowest electric field condition and the other two, suggesting that different mechanisms that may be related with the reversibility of the process are activated. As a result of the multifrequency information, the system is able to measure simultaneously the conductivity variations due to ion diffusion during electroporation. Finally, in order to reinforce the physical interpretation of the results, a complementary electrical equivalent model is used.

1 October 2019 in Bioelectrochemistry
Verified
Journal Article
Closed access
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
ILIsabelle Leray
Isabelle Leray
MRMattia Ronchetti
Mattia Ronchetti
RCRuggero Cadossi
Ruggero Cadossi
LMLluis M. Mir
Lluis M. Mir

1 May 2018 in Biochimica et Biophysica Acta (BBA) - Biomembranes
Verified
Journal Article
Closed access
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
CMCaterina Merla
Caterina Merla
JFJessica Fontaine
Jessica Fontaine
AMAdeline Muscat
Adeline Muscat
LMLluis M. Mir
Lluis M. Mir

21 May 2020 in IEEE Access
Verified
Journal Article
Open access
HSHéctor Sarnago
Héctor Sarnago
JBJose M. Burdio
Jose M. Burdio
TGTomas Garcia-Sanchez
Tomas Garcia-Sanchez
LPLluís Miquel Plà-Aragonès
Lluís Miquel Plà-Aragonès
IAIgnacio Alvarez-Gariburo
Ignacio Alvarez-Gariburo
Oscar LuciaOscar Lucia
Oscar Lucia
Biomedical applications often require high-performance power supplies for diagnosis and treatment systems. In particular, modern electroporation techniques for cancer treatment require high-voltage generators with versatile waveform generation. In this context, sinusoidal waveform generation has been recently identified as beneficial for electrochemotherapy cancer treatments. This paper proposes the design of a high-voltage high-frequency arbitrary waveform generator taking advantage of Gallium Nitride (GaN) devices. The proposed converter has been designed and implemented, achieving a 1-MHz 2000-V output voltage. It has been electrically tested and applied to electrochemotherapy treatments in mice, demonstrating the feasibility of this proposal.