Akira Kunimatsu

Akira Kunimatsu

Auto-generated profile, based on publicly available information

Akira Kunimatsu

Department of Radiology, Faculty of Medicine, the University of Tokyo, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Surgical Neurology International
Verified
Journal Article
Open access
SMSatoru Miyawaki
Satoru Miyawaki
HHHiroki Hongo
Hiroki Hongo
HIHideaki Imai
Hideaki Imai
YSYuki Shinya
Yuki Shinya
HOHideaki Ono
Hideaki Ono
NSNobuhito Saito
Nobuhito Saito
Intracranial atherosclerosis (ICAS) involves diverse histologies and several remodeling patterns. Ring finger protein 213 (RNF213) c.14576G>A variant (rs112735431), recently reported to be associated with ICAS, may be linked with negative remodeling (outer diameter - reducing morphological alteration) of intracranial arteries. This study investigated the outer diameter of atherosclerotic middle cerebral artery (MCA). Patients with unilateral atherosclerotic MCA stenosis/occlusion were enrolled in this single-hospital-based case-control study at The University of Tokyo Hospital. The patients were divided into two groups by the presence of RNF213 c.14576G>A (variant group and wild-type group) and the outer diameter of the MCA was measured with high-resolution magnetic resonance imaging. Twenty-eight patients with the wild type and 19 patients with the variant type were included. The outer diameter of the stenotic side MCA was smaller in the variant group than in the wild-type group (P = 8.3 × 10-6). The outer diameter of the normal side MCA was also smaller in the variant group than in the wild-type group (P = 5.2 × 10-3). The ratio of stenotic side to normal side was also smaller in the variant group than in the wild-type group (P = 1.5 × 10-5). This study indicates that RNF213 c.14576G>A is associated with negative remodeling of ICAS.

31 October 2011 in Ophthalmology
Verified
Journal Article
Closed access
TUTakashi Ueta
Takashi Ueta
HMHarushi Mori
Harushi Mori
AKAkira Kunimatsu
Akira Kunimatsu
TYTakuhiro Yamaguchi
Takuhiro Yamaguchi
YTYasuhiro Tamaki
Yasuhiro Tamaki
YYYasuo Yanagi
Yasuo Yanagi

1 September 2004 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
OAOsamu Abe
Osamu Abe
HMHarushi Mori
Harushi Mori
SAShigeki Aoki
Shigeki Aoki
AKAkira Kunimatsu
Akira Kunimatsu
NHNaoto Hayashi
Naoto Hayashi
KOKuni Ohtomo
Kuni Ohtomo
To evaluate diffusion tensor imaging (DTI) based on periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) compared with DTI based on single-shot echo planar imaging (EPI). Diffusion tensor data were acquired with PROPELLER (PROPELLER-DTI, 3 NEX), EPI (EPI-DTI2, 16 NEX) with the same acquisition time (11.4 minutes) and with EPI (EPI-DTI1, number of excitations = 4) with a shorter acquisition time (2.8 minutes). Regions of interest were set in the genu and splenium of the corpus callosum, as determined on T2-weighted fast spin echo images and fractional anisotropy (FA) maps, separately. Two neuroradiologists visually evaluated image distortion and quality in the supra- and infratentorial structures. In the genu, standard deviation determined by respective FA maps was decreased in order of PROPELLER-DTI, EPI-DTI1, and EPI-DTI2. Both EPI-DTI sequences were quantitatively superior in the splenium, but PROPELLER-DTI was less distorted. Periodically rotated overlapping parallel lines with enhanced reconstruction-DTI could become a complementary tool when qualitatively evaluating seriously distorted structures.

1 January 2011 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
MMMizuho Murakami
Mizuho Murakami
HMHarushi Mori
Harushi Mori
AKAkira Kunimatsu
Akira Kunimatsu
OAOsamu Abe
Osamu Abe
HCHirotaka Chikuda
Hirotaka Chikuda
KOKuni Ohtomo
Kuni Ohtomo
Magnetic resonance imaging (MRI) is the most popular follow-up study for patients who have undergone spinal surgery. However, the image quality often becomes poor because of artifacts from metal implants and/or from failed fat suppression, which obscure diagnosis. Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) is a new fat suppression method that is less affected by inhomogeneity of the magnetic field. Here, we compared postsurgical spinal MRI with IDEAL versus chemical shift selective saturation (CHESS). For 35 patients who had spinal surgery, we examined T2-weighted fast spin-echo sagittal images of the spine with both IDEAL and CHESS. Two radiologists evaluated the degrees of fat suppression and spinal canal projection from 0 (least/worst) to 2 (most/best). Fat suppression and spinal canal scores for IDEAL were statistically higher than those for CHESS (P < 0.05). Iterative decomposition of water and fat with echo asymmetry and least-squares estimation is clinically useful for postoperative spinal MRI.

28 October 2013 in Radiology
Verified
Journal Article
Closed access
SAShiori Amemiya
Shiori Amemiya
AKAkira Kunimatsu
Akira Kunimatsu
NSNobuhito Saito
Nobuhito Saito
KOKuni Ohtomo
Kuni Ohtomo

1 January 2003
Verified
Journal Article
Closed access
HMHarushi Mori
Harushi Mori
YMYoshitaka Masutani
Yoshitaka Masutani
SAShigeki Aoki
Shigeki Aoki
OAOsamu Abe
Osamu Abe
NHNaoto Hayashi
Naoto Hayashi
HKHiroyuki Kabasawa
Hiroyuki Kabasawa