Alexander Wilhelm Koch

Alexander Wilhelm Koch

Auto-generated profile, based on publicly available information

Alexander Wilhelm Koch

Institute for Measurement Systems and Sensor Technology, Technical University of Munich, Theresienstr. 90, 80333 Munich, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AHArsalan Haider
Arsalan Haider
MPMarcell Pigniczki
Marcell Pigniczki
SKShotaro Koyama
Shotaro Koyama
MKMichael Koehler
Michael Koehler
LHLukas Haas
Lukas Haas
AKAlexander W. Koch
Alexander W. Koch
In this work, we introduce a novel approach to model the rain and fog effect on the light detection and ranging (LiDAR) sensor performance for the simulation-based testing of LiDAR systems. The proposed methodology allows for the simulation of the rain and fog effect using the rigorous applications of the Mie scattering theory on the time domain for transient and point cloud levels for spatial analyses. The time domain analysis permits us to benchmark the virtual LiDAR signal attenuation and signal-to-noise ratio (SNR) caused by rain and fog droplets. In addition, the detection rate (DR), false detection rate (FDR), and distance error derror of the virtual LiDAR sensor due to rain and fog droplets are evaluated on the point cloud level. The mean absolute percentage error (MAPE) is used to quantify the simulation and real measurement results on the time domain and point cloud levels for the rain and fog droplets. The results of the simulation and real measurements match well on the time domain and point cloud levels if the simulated and real rain distributions are the same. The real and virtual LiDAR sensor performance degrades more under the influence of fog droplets than in rain.

1 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PKPatrick Kienle
Patrick Kienle
LBLorena Batarilo
Lorena Batarilo
MAMarkus Akgül
Markus Akgül
MKMichael Köhler
Michael Köhler
KWKun Wang
Kun Wang
AKAlexander W. Koch
Alexander W. Koch
Absolute distance measurement is a field of research with a large variety of applications. Laser triangulation is a well-tested and developed technique using geometric relations to calculate the absolute distance to an object. The advantages of laser triangulation include its simple and cost-effective setup with yet a high achievable accuracy and resolution in short distances. A main problem of the technology is that even small changes of the optomechanical setup, e.g., due to thermal expansion, lead to significant measurement errors. Therefore, in this work, we introduce an optical setup containing only a beam splitter and a mirror, which splits the laser into a measurement beam and a reference beam. The reference beam can then be used to compensate for different error sources, such as laser beam dithering or shifts of the measurement setup due to the thermal expansion of the components. The effectiveness of this setup is proven by extensive simulations and measurements. The compensation setup improves the deviation in static measurements by up to 75%, whereas the measurement uncertainty at a distance of 1 m can be reduced to 85 μm. Consequently, this compensation setup can improve the accuracy of classical laser triangulation devices and make them more robust against changes in environmental conditions.

4 August 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
QBQiang Bian
Qiang Bian
CBConstantin Bauer
Constantin Bauer
ASAndrea Stadler
Andrea Stadler
MLMarkus Lindner
Markus Lindner
MJMartin Jakobi
Martin Jakobi
JRJohannes Roths
Johannes Roths
In-situ temperature and strain during copper casting process were monitored for the first time based on regenerated fiber Bragg grating (RFBG) sensors, with the maximum temperature up to 1100 $^{\circ }$ C and the largest compressive strain approximately −14 000 $\mu$ $\varepsilon$ . A generalized fifth-order polynomial calibration function was used to convert the measured Bragg wavelengths from RFBG into temperature values. With an RFBG temperature sensor array, the temperature distribution as a function of time was obtained, revealing how the temperature gradient changed during the casting process. In-situ strain was measured by an RFBG strain sensor in direct contact with copper, showing the strain progression inside the copper at different temperatures during the casting. The RFBG-based in-situ monitoring method provides a new way for measuring multiple parameters in high temperature casting, which can be used for improving the design of the casting mold and upgrading the casting quality. Furthermore, our investigation lays a good foundation for fiber-embedded smart metal structures as it shows that fiber sensors can be embedded in copper casts without special surface treatment.

15 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
LBLaura Maria Bilgeri
Laura Maria Bilgeri
FBFelix Salazar Bloise
Felix Salazar Bloise
MLMin Lu
Min Lu
AKAlexander W. Koch
Alexander W. Koch
The surface structure, especially the roughness, has a significant influence on numerous parameters, such as friction and wear, and therefore estimates the quality of technical systems. In the last decades, a broad variety of surface roughness measurement methods were developed. A destructive measurement procedure or the lack of feasibility of online monitoring are the crucial drawbacks of most of these methods. This article proposes a new non-contact method for measuring the surface roughness that is straightforward to implement and easy to extend to online monitoring processes. The key element is a liquid-crystal-based spatial light modulator, integrated in an interferometric setup. By varying the imprinted phase of the modulator, a correlation between the imprinted phase and the fringe visibility of an interferogram is measured, and the surface roughness can be derived. This paper presents the theoretical approach of the method and first simulation and experimental results for a set of surface roughnesses. The experimental results are compared with values obtained by an atomic force microscope and a stylus profiler.

12 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FDFranz Dutz
Franz Dutz
AHAndreas Heinrich
Andreas Heinrich
RBRolf Bank
Rolf Bank
AKAlexander W. Koch
Alexander W. Koch
JRJohannes Roths
Johannes Roths
A low-drift fiber-optic sensor system, consisting of 24 regenerated fiber Bragg gratings (RFBG), equally distributed over a length of 2.3 m, is presented here. The sensor system can monitor spatially extended temperature profiles with a time resolution of 1 Hz at temperatures of up to 500 °C. The system is intended to be used in chemical reactors for both the control of the production ramp-up, where a fast time response is needed, as well as for production surveillance, where low sensor drifts over several years are required. The fiber-optic sensor system was installed in a pilot test reactor and was exposed to a constant temperature profile, with temperatures in the range of 150–500 °C for more than two years. During this period, the temperature profile was measured every three to five months and the fiber-optic temperature data were compared with data from a three-point thermocouple array and a calibrated single-point thermocouple. A very good agreement between all temperature measurements was found. The drift rates of the 24 RFBG sensor elements were determined by comparing the Bragg wavelengths at a precisely defined reference temperature near room temperature before and after the two-year deployment. They were found to be in the range of 0.0 K/a to 2.3 K/a, with an average value of 1.0 K/a. These low drift rates were achieved by a dedicated temperature treatment of the RFBGs during fabrication. Here, the demonstrated robustness, accuracy, and low drift characteristics show the potential of fiber-optic sensors for future industrial applications.

5 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AHArsalan Haider
Arsalan Haider
MPMarcell Pigniczki
Marcell Pigniczki
MKMichael Koehler
Michael Koehler
MFMaximilian Fink
Maximilian Fink
MSMichael Schardt
Michael Schardt
AKAlexander W. Koch
Alexander W. Koch
This work introduces a process to develop a tool-independent, high-fidelity, ray tracing-based light detection and ranging (LiDAR) model. This virtual LiDAR sensor includes accurate modeling of the scan pattern and a complete signal processing toolchain of a LiDAR sensor. It is developed as a functional mock-up unit (FMU) by using the standardized open simulation interface (OSI) 3.0.2, and functional mock-up interface (FMI) 2.0. Subsequently, it was integrated into two commercial software virtual environment frameworks to demonstrate its exchangeability. Furthermore, the accuracy of the LiDAR sensor model is validated by comparing the simulation and real measurement data on the time domain and on the point cloud level. The validation results show that the mean absolute percentage error (MAPE) of simulated and measured time domain signal amplitude is 1.7%. In addition, the MAPE of the number of points Npoints and mean intensity Imean values received from the virtual and real targets are 8.5% and 9.3%, respectively. To the author’s knowledge, these are the smallest errors reported for the number of received points Npoints and mean intensity Imean values up until now. Moreover, the distance error derror is below the range accuracy of the actual LiDAR sensor, which is 2 cm for this use case. In addition, the proving ground measurement results are compared with the state-of-the-art LiDAR model provided by commercial software and the proposed LiDAR model to measure the presented model fidelity. The results show that the complete signal processing steps and imperfections of real LiDAR sensors need to be considered in the virtual LiDAR to obtain simulation results close to the actual sensor. Such considerable imperfections are optical losses, inherent detector effects, effects generated by the electrical amplification, and noise produced by the sunlight.