Jaime Lopez Sanchez

Jaime Lopez Sanchez

Auto-generated profile, based on publicly available information

Jaime Lopez Sanchez

Univ. de Barcelona (Spain)

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2005
Verified
Conference Paper
Closed access
JBJ. Brufau
J. Brufau
MPManuel Puig
Manuel Puig
JLJ. Lopez-Sanchez
J. Lopez-Sanchez
JSJ. Samitier
J. Samitier
NSN. Snis
N. Snis
HWH. Woern
H. Woern
Manipulating in the micro- or even nano world still poses a great challenge to robotics. Conventional (stationary) systems suffer from drawbacks regarding integration into process supervision and multi-robot approaches, which become highly relevant to fight scaling effects. This paper describes work currently being carried out which aims to make automated manipulation of micrometer-scaled objects possible by robots with nanometer precision. The goal is to establish a small cluster of (up to five) micro robots equipped with on-board electronics, sensors and wireless power supply. Power autonomy has been reached using inductive energy transmission from an external wireless power supply system or a battery based system. Electronics requirements are fulfilled in the electronic module with the full custom integrated circuit design for the robot locomotion control and the closed loop force control for AFM tool in cell manipulation applications. The maximum velocity obtained i s about 0.4 mm/s with a saw tooth voltage signals of 20Vpp and 2500 Hz. In order to keep a AFM tool on micro-robot a specific tip with integrated piezoresistance, instead of the classical laser beam methodology, is validated for force measurement

1 February 2004 in Anesthesiology
Verified
Journal Article
Open access
ACAnne L. Chowet
Anne L. Chowet
JLJaime R. Lopez
Jaime R. Lopez
JBJohn G. Brock-Utne
John G. Brock-Utne
RJRichard A. Jaffe
Richard A. Jaffe
Background: It is common practice to hyperextend the wrist to facilitate insertion of a radial intra-arterial catheter. This position may be maintained for prolonged periods. Although there has been much discussion about optimal patient management to protect the ulnar nerve and brachial plexus, little attention has been paid to the median nerve during wrist hyperextension. The authors report the effects of wrist hyperextension on conduction in the median nerve. Methods: Median nerve conduction was studied in 12 awake, healthy volunteers using standard nerve conduction tests consisting of the measurement of compound sensory and motor action potentials, as well as their amplitudes and latencies. With the contralateral hand as a control, the right wrist was placed in hyperextension (angled between 65 and 80 degrees), and compound action potentials were recorded to determine the onset and magnitude of effects. Subsequently, the hand was released from hyperextension and recovery was recorded. Results: In 83% of subjects, hyperextension resulted in a significant decrease in compound sensory action potential amplitudes, sufficient to qualify as conduction block (16.6% of baseline). The average time to conduction block was 43 +/- 13.2 min. All subjects who manifested conduction block showed marked improvement 5 min after release from hyperextension. Conclusions: Wrist hyperextension for arterial line placement and stabilization is likely to result in profound impairment of median nerve function. Although the effects were transient in this study, the results suggest that prolonged hyperextension may be associated with significant changes in median nerve conduction. To minimize the chance for nerve injury, the authors recommend that wrists be returned promptly to the neutral position following arterial line placement.

1 October 1993 in Neurology
Verified
Journal Article
Closed access
JLJaime R. Lopez
Jaime R. Lopez
BABruce T. Adornato
Bruce T. Adornato
WHW. F. Hoyt
W. F. Hoyt

1 November 2014
Verified
Conference Paper
Closed access
PMP. Miribel-Catala
P. Miribel-Catala
JCJ. Colomer-Fararons
J. Colomer-Fararons
JBJ. Lafuente Brinquis
J. Lafuente Brinquis
JLJ. Lopez-Sanchez
J. Lopez-Sanchez
This paper proposes a low-cost true self-powered start-up and control circuitry for an envisaged system based on commercial vibration energy harvesting sources, that is oriented to structural health monitoring (SHM) applications. The proposed circuitry is quite simple and assures a battery less system just working with piezoelectrical generators. This architecture works looking for the maximum mechanical to electrical efficiency conversion, thanks to a continuous check of the open-load voltage at the piezoelectric generator, disconnecting it from the electronic circuitry, defining a true adaptive control unit. Also it is addressed the cold-start of the system. Initial experimental results are provided to verify its performance.

1 November 2015
Verified
Conference Paper
Closed access
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
JLJaime Lopez-Sanchez
Jaime Lopez-Sanchez
PMPere Miribel-Catala
Pere Miribel-Catala
A novel piezoelectric harvester-based self-powered adaptive solution with wireless data transmission capability for structural health monitoring is presented. This work demonstrates the accomplishment of maximum power transferred condition for a wide range load conditions and for different amplitudes and frequencies oscillation of the piezoelectric transducer. The characterization of the wireless transmission of temperature and open voltage circuit of the piezoelectric transducer is also presented to support the use of this solution as a wireless self-powered adaptive structural health monitor solution.

1 June 2015
Verified
Conference Paper
Closed access
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
JLJaime Lopez-Sanchez
Jaime Lopez-Sanchez
PMPere Miribel-Catala
Pere Miribel-Catala
This manuscript presents a Piezoelectric Harvester based on a novel analog control unit to assures a maximum power transmission. Also in this paper it is presented a study of the transferred power between the piezoelectric generator and a load based on data obtained by simulation and experimentally. In addition, results of experimental test of the system for its application as Structural Health Monitoring is presented.