Jixiang Guo

Jixiang Guo

Auto-generated profile, based on publicly available information

Jixiang Guo

College of Computer Science, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Medical Image Analysis
Verified
Journal Article
Closed access
XXXiuyuan Xu
Xiuyuan Xu
CWChengdi Wang
Chengdi Wang
JGJixiang Guo
Jixiang Guo
YGYuncui Gan
Yuncui Gan
JWJianyong Wang
Jianyong Wang
ZYZhang Yi
Zhang Yi

1 April 2020 in Medical Image Analysis
Verified
Journal Article
Closed access
THTao He
Tao He
JHJunjie Hu
Junjie Hu
YSYing Song
Ying Song
JGJixiang Guo
Jixiang Guo
ZYZhang Yi
Zhang Yi

1 March 2022 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
JYJie Yao
Jie Yao
WZWei Zeng
Wei Zeng
THTao He
Tao He
SZShanluo Zhou
Shanluo Zhou
YZYi Zhang
Yi Zhang
WTWei Tang
Wei Tang

30 September 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
LYLe Yi
Le Yi
LZLei Zhang
Lei Zhang
XXXiuyuan Xu
Xiuyuan Xu
JGJixiang Guo
Jixiang Guo
Radiographic attributes of lung nodules remedy the shortcomings of lung cancer computer-assisted diagnosis systems, which provides interpretable diagnostic reference for doctors. However, current studies fail to dedicate multi-label classification of lung nodules using convolutional neural networks (CNNs) and are inferior in exploiting statistical dependency between the labels. In addition, data imbalance is an indispensable problem to be reckoned with when employing CNNs to perform lung nodule classification. It introduces greater challenges especially in the multi-label classification. In this paper, we propose a method called MLSL-Net to discriminate lung nodule characteristics and simultaneously address the challenges. Particularly, the proposal employs multi-label softmax loss (MLSL) as the performance index, aiming to reduce the ranking errors between the labels and within the labels during training, thereby optimizing ranking loss and AUC directly. Such criterions can better evaluate the classifier’s performance on the multi-label imbalanced dataset. Furthermore, a scale factor is introduced based on the investigation of the max surrogate function. Different from preceding usages, the small factor is used so that to narrow the discrepancy of gradients produced by different labels. More interestingly, this factor also facilitates the exploit of label dependency. Experimental results on the LIDC-IDRI dataset as well as another akin dataset demonstrate that MLSL-Net can effectively perform multi-label classification despite the imbalance issue. Meanwhile, the results confirm the responsibility of the factor for capturing label correlations, accordingly leading to more accurate predictions.

1 November 2018 in Knowledge-Based Systems
Verified
Journal Article
Closed access
MYMing Yan
Ming Yan
JGJixiang Guo
Jixiang Guo
WTWeidong Tian
Weidong Tian
ZYZhang Yi
Zhang Yi

27 June 2024 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
PDF file
WLWei Liu
Wei Liu
XLXiang Li
Xiang Li
CLChang Liu
Chang Liu
GGGe Gao
Ge Gao
YXYutao Xiong
Yutao Xiong
WTWei Tang
Wei Tang
Objectives: To develop and validate a modified deep learning (DL) model based on nnU-Net for classifying and segmenting five-class jaw lesions using cone-beam CT (CBCT). Methods: A total of 368 CBCT scans (37 168 slices) were used to train a multi-class segmentation model. The data underwent manual annotation by two oral and maxillofacial surgeons (OMSs) to serve as ground truth. Sensitivity, specificity, precision, F1-score, and accuracy were used to evaluate the classification ability of the model and doctors, with or without artificial intelligence assistance. The dice similarity coefficient (DSC), average symmetric surface distance (ASSD), and segmentation time were used to evaluate the segmentation effect of the model. Results: The model achieved the dual task of classifying and segmenting jaw lesions in CBCT. For classification, the sensitivity, specificity, precision, and accuracy of the model were 0.871, 0.974, 0.874, and 0.891, respectively, surpassing oral and maxillofacial radiologists (OMFRs) and OMSs, approaching the specialist. With the model's assistance, the classification performance of OMFRs and OMSs improved, particularly for odontogenic keratocyst (OKC) and ameloblastoma (AM), with F1-score improvements ranging from 6.2% to 12.7%. For segmentation, the DSC was 87.2% and the ASSD was 1.359 mm. The model's average segmentation time was 40 ± 9.9 s, contrasting with 25 ± 7.2 min for OMSs. Conclusions: The proposed DL model accurately and efficiently classified and segmented five classes of jaw lesions using CBCT. In addition, it could assist doctors in improving classification accuracy and segmentation efficiency, particularly in distinguishing confusing lesions (eg, AM and OKC).