Sarah S. L. Chow

Sarah S. L. Chow

Auto-generated profile, based on publicly available information

Sarah S. L. Chow

University of Washington, Department of Mechanical Engineering, Seattle, Washington, United States

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
KBKevin W. Bishop
Kevin W. Bishop
LBLindsey A. Erion Barner
Lindsey A. Erion Barner
QHQinghua Han
Qinghua Han
EBElena Baraznenok
Elena Baraznenok
LLLydia Lan
Lydia Lan
JLJonathan Liu
Jonathan Liu

2 November 2023 in The Journal of Pathology: Clinical Research
Verified
Journal Article
Open access
JLJonathan Liu
Jonathan Liu
SCSarah Sl Chow
Sarah Sl Chow
RCRichard Colling
Richard Colling
MDMichelle R Downes
Michelle R Downes
XFXavier Farré
Xavier Farré
LTLawrence D True
Lawrence D True
In recent years, technological advances in tissue preparation, high‐throughput volumetric microscopy, and computational infrastructure have enabled rapid developments in nondestructive 3D pathology, in which high‐resolution histologic datasets are obtained from thick tissue specimens, such as whole biopsies, without the need for physical sectioning onto glass slides. While 3D pathology generates massive datasets that are attractive for automated computational analysis, there is also a desire to use 3D pathology to improve the visual assessment of tissue histology. In this perspective, we discuss and provide examples of potential advantages of 3D pathology for the visual assessment of clinical specimens and the challenges of dealing with large 3D datasets (of individual or multiple specimens) that pathologists have not been trained to interpret. We discuss the need for artificial intelligence triaging algorithms and explainable analysis methods to assist pathologists or other domain experts in the interpretation of these novel, often complex, large datasets.

1 March 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RWRui Wang
Rui Wang
SCSarah S. L. Chow
Sarah S. L. Chow
RSRobert B. Serafin
Robert B. Serafin
WXWeisi Xie
Weisi Xie
QHQinghua Han
Qinghua Han
JLJonathan Liu
Jonathan Liu
Prostate cancer is the most prevalent form of cancer and is the second leading cause of cancer-related deaths among men in the United States.1 Every year, nearly 250,000 men are diagnosed with this disease in the United States. Morbidity and mortality rates are low, but there is a fraction of prostate cancer cases that are potentially lethal and for whom aggressive treatments are warranted. To determine whether a patient requires aggressive treatment, urologists rely heavily upon the Gleason score reported by pathologists. Gleason scoring is based solely on the visual interpretation of prostate gland morphology, as seen on a few 2D histology slides. Unfortunately, there is a high level of interobserver variability associated with Gleason grading of prostate cancer2,3 and the Gleason scores are only moderately correlated with outcomes, particularly for patients with intermediate-grade prostate cancer.4 This can lead to the undertreatment of some patients,5 resulting in preventable metastasis and death,6 and overtreatment of other patients,7 which can lead to financial burdens and avoidable side effects, such as incontinence and impotence.8

31 October 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
KBKevin W. Bishop
Kevin W. Bishop
BHBingwen Hu
Bingwen Hu
RVRajat Vyawhare
Rajat Vyawhare
ZYZelin Yang
Zelin Yang
DLDavid C. Liang
David C. Liang
JLJonathan Liu
Jonathan Liu
A miniature optical-sectioning fluorescence microscope with high sensitivity and resolution would enable non-invasive and real-time tissue inspection, with potential use cases including early disease detection and intraoperative guidance. Previously, we developed a miniature MEMS-based dual-axis confocal (DAC) microscope that enabled video-rate optically sectioned in vivo microscopy of human tissues. However, the device’s clinical utility was limited due to a small field of view, a non-adjustable working distance, and a lack of a sterilization strategy. In our latest design, we have made improvements to achieve a 2x increase in the field of view (600 × 300 µm) and an adjustable working distance range of 150 µm over a wide range of excitation/emission wavelengths (488–750 nm), all while maintaining a high frame rate of 15 frames per second (fps). Furthermore, the device is designed to image through a disposable sterile plastic drape for convenient clinical use. We rigorously characterize the performance of the device and show example images of ex vivo tissues to demonstrate the optical performance of our new design, including fixed mouse skin and human prostate, as well as fresh mouse kidney, mouse intestine, and human head and neck surgical specimens with corresponding H&E histology. These improvements will facilitate clinical testing and translation.