Liv Egnell

Liv Egnell

Auto-generated profile, based on publicly available information

Liv Egnell

Radiobotics ApS

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
LELiv Egnell
Liv Egnell
IVIgor Vidić
Igor Vidić
NJNeil P. Jerome
Neil P. Jerome
ABAnna M. Bofin
Anna M. Bofin
TBTone Frost Bathen
Tone Frost Bathen
PGPål Erik Goa
Pål Erik Goa
Background: Increased deposition and reorientation of stromal collagen fibers are associated with breast cancer progression and invasiveness. Diffusion‐weighted imaging (DWI) may be sensitive to the collagen fiber organization in the stroma and could provide important biomarkers for breast cancer characterization.Purpose: To understand how collagen fibers influence water diffusion in vivo and evaluate the relationship between collagen content and the apparent diffusion coefficient (ADC) and the signal fractions of the biexponential model using a high b‐value scheme.Study Type: Prospective.Subjects/Specimens: Forty‐five patients with benign (n = 8), malignant (n = 36), and ductal carcinoma in situ (n = 1) breast tumors. Lesions and normal fibroglandular tissue (n = 9) were analyzed using sections of formalin‐fixed, paraffin‐embedded tissue stained with hematoxylin, erythrosine, and saffron.Field Strength/Sequence: MRI (3T) protocols: Protocol I: Twice‐refocused spin‐echo echo‐planar imaging with: echo time (TE) 85 msec; repetition time (TR) 9300/11600 msec; matrix 90 × 90 × 60; voxel size 2 × 2 × 2.5 mm3; b‐values: 0 and 700 s/mm2. Protocol II: Stejskal–Tanner spin‐echo echo‐planar imaging with: TE: 88 msec; TR: 10600/11800 msec, matrix 90 × 90 × 60; voxel size 2 × 2 × 2.5 mm3; b‐values [0, 200, 600, 1200, 1800, 2400, 3000] s/mm2.Assessment: Area fractions of cellular and collagen content in histologic sections were quantified using whole‐slide image analysis and compared with the corresponding DWI parameters.Statistical Tests: Correlations were assessed using Pearson's r. Univariate analysis of group median values was done using the Mann–Whitney U‐test.Results: Collagen content correlated with the fast signal fraction (r = 0.67, P < 0.001) and ADC (r = 0.58, P < 0.001) and was lower (P < 0.05) in malignant lesions than benign and normal tissues. Cellular content correlated inversely with the fast signal fraction (r = –0.67, P < 0.001) and ADC (r = –0.61, P < 0.001) and was different (P < 0.05) between malignant, benign, and normal tissues.Data Conclusion: Our findings suggest stromal collagen content increases diffusivity observed by MRI and is associated with higher ADC and fast signal fraction of the biexponential model.Level of Evidence: 3Technical Efficacy Stage: 3J. Magn. Reson. Imaging 2020;51:1868–1878.

16 August 2023 in medRxiv
Verified
Preprint
Open access
PDF file
HRHuib Ruitenbeek
Huib Ruitenbeek
LELiv Egnell
Liv Egnell
KZKatharina Ziegeler
Katharina Ziegeler
MBMathias Willadsen Brejnebøl
Mathias Willadsen Brejnebøl
JNJanus Uhd Nybing
Janus Uhd Nybing
JVJacob Visser
Jacob Visser
Background Rapidly diagnosing fractures in appendicular skeletons is vital in the ED, where junior physicians often interpret initial radiographs. However, missed fractures remain a concern, prompting AI-assisted detection exploration. Yet, existing studies lack clinical context. We propose a multi-center retrospective study evaluating the AI aid RBfracture™ v.1, aiming to assess AI’s impact on diagnostic thinking by analyzing consecutive cases with clinical data, providing insights into fracture detection and clinical decision-making. Objectives To provide new insights on the potential value of AI tools across borders and different healthcare systems. We will evaluate the performance of the AI aid to detect fractures on conventional x-ray images and how its use could affect handling of these cases in a healthcare setting. In order to explore if the use of a trained and certified AI tool on clinical data exposes new challenges, a daily practice clinical scenario will be approached by minimising selection criteria and using consecutive cases. A multicenter, retrospective, diagnostic accuracy cross-sectional design incorporates clinical context. Methods The multicenter study spans three European sites without onsite hardware. AI system RBfracture™ v.1 maintains consistent sensitivity and specificity thresholds. Eligibility involves age ≥21 with x-ray indications for appendicular fractures. Exclusions include casts, follow-up x-rays, nearby hardware. AI aids retrospective fracture detection. Reader sessions include radiology and emergency care residents and trainees reading with and without AI. Fractures are marked, rated, with expert-established reference standards. Data Sequential patient studies at three sites yield 500 cases per site. Data includes anatomy, referral notes, radiology reports, and radiographic images. Expert readers use annotations, clinical context for standards. Statistical methods include dichotomized confidence ratings, sensitivity, specificity calculations, site-based analysis and subgroup considerations. Reference Standard Two experienced readers annotate fractures; if their annotations overlap by 25% or more, the common area is the reference. Discrepancies are resolved by a local expert. Individual fractures are labelled.

30 August 2022 in medRxiv
Verified
Preprint
Open access
PDF file
MBMathias Willadsen Brejnebøl
Mathias Willadsen Brejnebøl
LELiv Egnell
Liv Egnell
MLMichael Lundemann
Michael Lundemann
ALAnders Lenskjold
Anders Lenskjold
JNJanus Uhd Nybing
Janus Uhd Nybing
MBMikael Boesen
Mikael Boesen
Background: Radiographic evaluation of knee osteoarthritis (KOA) commonly supports clinical findings. Ground truth is difficult to establish and concerns exist on the inter-and intrarater agreement of the findings. RBknee™ is a CE-marked and FDA-cleared AI tool for automatic assessment and reporting of radiographic KOA on standard projection radiographs. Objectives: To investigate how the use of an AI tool affects the accuracy among human readers across three European hospitals in grading the severity of osteoarthritis and associated individual radiographic features. In addition, the performance of the AI tool will also be compared to reference standards established by experts in a stand-alone validation. Methods: In this retrospective multicenter, fully-crossed, multi-reader, multi-case (MRMC) study, the AI support tool RBknee is introduced as a diagnostic intervention. Four Index Readers from each site (two orthopaedic surgeons and two radiologists) will read all studies twice in two runs separated by a washout period of at least four weeks. In both runs, the experiment will be arranged so that the AI-aid will be available for half of the images in the first session and for the second half of the images in the second session. The order of the images will be randomised in order to minimise temporal effects and biases. The primary endpoint is the difference in diagnostic test accuracy for radiographic KOA grading without and with the aid of the AI tool and will be measured as the ordinal weighted accuracy. Data: The data includes radiographic images from 225 studies (unique patients, retrospective data) with weight-bearing bilateral PA/AP and LAT projections of the symptomatic knee(s). Each site contributes to the cohort with 75 studies of which 70 will be consecutive and 5 will be selected to balance the prevalence of radiographic KOA severity. Reference standard: The reference standard will be established based on independent grading by three KOA Reference Experts and adjudicated by majority vote. Where impossible to resolve by majority voting, adjudication will be established by consensus. Index test, AI tool (stand-alone validation): The diagnostic accuracy of RBknee will be tested against the reference standard. Index test, Index Readers: The 12 readers will grade KL on the PA/AP projection and patellar osteophytes on the lateral projection. Administrative information: Title: The trial is titled “AutoRayValid-RBknee”. Protocol version: Revision History Funding: This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 954221 for the EIC SME Instrument project AutoRay. The work only reflects the authors’ view and the European Commission is not responsible for any use that may be made from the information it contains. Roles and responsibilities: Authors’ contributions: MWB, MB, EHGO, JV, and KGH initiated the study design and AL, JUN, KZ and HR helped with implementation. MWB, LE and MJL provided statistical expertise in clinical study design and MWB is conducting the primary statistical analysis. MWB, MJL and LE prepared the manuscript and all authors contributed to its refinement and approved the final manuscript. Sponsor Contact information: Trial Sponsor: Radiobotics ApS Contact name: Liv Egnell Address: Esplanaden 8C, 1263 Copenhagen K, Denmark Email: liv@radiobotics.com