Ricardo Cesar Solis

Ricardo Cesar Solis

Auto-generated profile, based on publicly available information

Ricardo Cesar Solis

Servicio de Neumología y Cuidados Intensivos, Hospital Universitario "Dr. José Eleuterio González", Universidad Autónoma de Nuevo León, CIPTR, Monterrey, NL, México; Unidad de Pleura y Ecografía Torácica, Servicio de Neumología y Cuidados Intensivos, Hospital Universitario "Dr. José Eleuterio González", Universidad Autónoma de Nuevo León, Monterrey, NL, México

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2020 in International Journal of Endocrinology
Verified
Journal Article
Open access
PDF file
ASAdriana Sánchez-García
Adriana Sánchez-García
RRRené Rodríguez-Gutiérrez
René Rodríguez-Gutiérrez
LMLeonardo Mancillas-Adame
Leonardo Mancillas-Adame
VGVictoria González-Nava
Victoria González-Nava
AGAlejandro Díaz González-Colmenero
Alejandro Díaz González-Colmenero
JGJosé Gerardo González-González
José Gerardo González-González
Introduction. The triglyceride and glucose (TyG) index has been described as a biochemical marker of insulin resistance (IR); however, its diagnostic accuracy remains uncertain. Objective. To summarize the evidence assessing the diagnostic accuracy of the TyG index regarding IR. Methods. A comprehensive search in MEDLINE, EMBASE, Web of Science, and Scopus was performed without any language restriction. Studies assessing the diagnostic accuracy of the TyG index against the hyperinsulinemic-euglycemic clamp (HIEC) or any other IR biochemical were assessed independently and in duplicate. Diagnostic accuracy measures (sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratios) were extracted independently and in duplicate. The QUADAS-2 tool was used to assess the risk of bias of independent studies. Results. We identified 15 eligible studies with 69,922 participants and an overall quality of low to moderate. The TyG index was evaluated by HIEC and HOMA as reference tests. The highest achieved sensitivity was 96% using HIEC, and the highest specificity was of 99% using HOMA-IR, with a cutoff value of 4.68. AUC values varied from 0.59 to 0.88. Cutoff values for IR were variable between studies, limiting its comparability. Conclusion. In this systematic review, we found moderate-to-low quality evidence about the usefulness of the TyG index as a surrogate biochemical marker of IR. Due to the lack of a standardized IR definition and heterogeneity between studies, further validation and standardized cutoff values are needed to be used in clinical practice.

1 January 2020 in Endocrine Practice
Verified
Journal Article
Closed access
JMJuan Montes-Villarreal
Juan Montes-Villarreal
LPLuis Alberto Perez-Arredondo
Luis Alberto Perez-Arredondo
RRRene Rodriguez-Gutierrez
Rene Rodriguez-Gutierrez
AGAlejandro Diaz Gonzalez-Colmenero
Alejandro Diaz Gonzalez-Colmenero
RSRicardo Cesar Solis
Ricardo Cesar Solis
LMLeonardo G. Mancillas-Adame
Leonardo G. Mancillas-Adame

9 July 2021 in BMJ Open
Verified
Journal Article
Open access
PDF file
JGJosé Gerardo González-González
José Gerardo González-González
AGAlejandro Díaz González-Colmenero
Alejandro Díaz González-Colmenero
JMJuan Manuel Millán-Alanís
Juan Manuel Millán-Alanís
LLLyubov Lytvyn
Lyubov Lytvyn
RSRicardo Cesar Solis
Ricardo Cesar Solis
RRRené Rodríguez-Gutiérrez
René Rodríguez-Gutiérrez
Objectives Assess values, preferences and burden of treatment that patients with type 2 diabetes consider when initiating glucagon-like peptide-1 receptor agonists (GLP-1 RA) or sodium-glucose cotransporter-2 inhibitors (SGLT-2i) compared with other glucose-lowering options. Methods Paired reviewers independently included studies reporting quantitative or qualitative methods to assess values, preferences and burden of treatment reported by patients with type 2 diabetes regarding the initiation of GLP-1 RA or SGLT-2i over other alternatives. A systematic search in MEDLINE, Scopus, EMBASE, Web of Science and Cochrane Central Register of Controlled Trials from inception until May 2020 was performed by an experienced librarian. Risk of bias was assessed with a specifically designed tool for values and preferences studies. Results 17 studies (7296 patients) proved eligible. Studies fulfilling criteria for SGLT-2i were not identified. Five studies (2662 patients) evaluated preferences for GLP-1 RA compared with other glucose-lowering medications. 12 studies (4634 patients) evaluated preferences between, at least, two kinds of GLP-1 RA or their injection devices based on the following attributes: efficacy, dose, application frequency, device characteristics. Among studies comparing GLP-1 RA to other glucose-lowering medications, some preferences were observed for dypeptil peptidase-4 inhibitors compared with once daily liraglutide. Comparing different attributes of GLP-1 RA drugs and devices, cardiovascular risk reduction, glucose lowering potential, once weekly and simple administered regimens were the most preferred. Conclusions As no evidence for preferences on SGLT-2i was available, only preferences for GLP-1 RA were assessed; however, evidence is still limited for the latter. Studies comparing preferences for GLP1-RA to other glucose-lowering alternatives only included twice daily or once daily injection regimens of GLP-1 RA drugs. According to our findings, once weekly alternatives are widely preferred than the formers. The extent to which patients with type 2 diabetes value reduced adverse cardiovascular and kidney outcomes, weighed benefits against harms and burden of treatment is limited and with very low certainty. PROSPERO registration number CRD42020159284.

12 February 2019 in International Journal of Endocrinology
Verified
Journal Article
Open access
PDF file
RRRene Rodriguez-Gutierrez
Rene Rodriguez-Gutierrez
LMLeonardo G. Mancillas-Adame
Leonardo G. Mancillas-Adame
GRGiselle Rodríguez-Tamez
Giselle Rodríguez-Tamez
AGAlejandro Diaz Gonzalez-Colmenero
Alejandro Diaz Gonzalez-Colmenero
RSRicardo Cesar Solis-Pacheco
Ricardo Cesar Solis-Pacheco
JGJosé Gerardo Gonzalez-Gonzalez
José Gerardo Gonzalez-Gonzalez
Background. Hypertriglyceridemia and hyperglycemia coexist in 30-60% of patients with diabetes. The impact of hypertriglyceridemia regarding HbA1c assay reliability remains uncertain. Therefore, we conducted a prospectivein vivocontrolled study with the aim of defining the association between triglyceride levels and HbA1c.Methods. A total of 44 patients with an index-hospital admission diagnosis of diabetic ketoacidosis or hypertriglyceridemia-induced pancreatitis, as a model for acute elevation of triglycerides, were recruited. Blood samples were drawn for the measurement of HbA1c, triglycerides, glucose, and hemoglobin at baseline and subsequently 24 and 48 hours after admission. HbA1c analysis was performed with high-performance liquid chromatography Bio-Rad D10 (NGSP approved).Results. All patients completed the study protocol. A difference between mean triglycerides from day 0 (baseline) to day 2 of 1567.2 mg/dL was observed. We found a difference between mean serum HbA1c from days 0 to 2 of 0.09% [1 mmol/mol] (p=0.004). Moreover, a weak correlation between the mean difference of HbA1c and triglycerides from baseline to day 2 was found to be statistically significant (r=0.256,p=0.015). None of these findings, however, are clinically significant.Conclusion. Triglycerides do not impair the interpretation of HbA1c assay. Patients and clinicians can now be confident that hypertriglyceridemia is not an important factor when interpreting HbA1c results.

15 November 2024 in POCUS Journal
Verified
Journal Article
Open access
PDF file
ERErick Joel Rendon Ramirez
Erick Joel Rendon Ramirez
AMAndrés Mauricio Morales-García
Andrés Mauricio Morales-García
ARAdrián Rendón
Adrián Rendón
HNHomero Nañez-Terreros
Homero Nañez-Terreros
RSRicardo César Solis
Ricardo César Solis
JPJosé M. Porcel
José M. Porcel
Aim: To analyze the association between pleural effusion detected by chest point of care ultrasound (POCUS) and clinical outcomes in patients with septic shock admitted to an intensive care unit (ICU). Material and methods: A prospective evaluation of ICU patients with septic shock in whom chest POCUS was performed during the first 24 hours of diagnosis to identify the presence and characteristics of pleural effusion. Results: Of 45 patients with septic shock, 17 (38%) had pleural effusion. Mortality (13 vs 17 patients, p=0.44), as well as length of stay in ICU (11.0 vs 6.5 days, p=0.161) were similar among groups. However, there was a significant difference in the modified Nutrition Risk in Critically Ill (mNUTRIC) score between the pleural effusion (5.82±1.13) and non-pleural effusion groups (4.00±2.39, p=0.001). In addition, patients with pleural effusion required more days on mechanical ventilation than those without pleural effusion (10 vs 7, p=0.04). A subgroup analysis of chest POCUS characteristics between surviving and non-surviving patients with pleural effusion identified a higher median size of pleural effusion in the non-surviving group (3±2.16 cm vs 1.9±0.6, p=0.01). Conclusion: Pleural effusion in patients with septic shock is associated with high mNUTRIC scores and more days on mechanical ventilation. The larger the pleural effusion, the lower the survival rate.