Andrew Shepard

Andrew Shepard

Auto-generated profile, based on publicly available information

Andrew Shepard

Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, United States; Department of Radiation Oncology, University of Iowa, Iowa City, IA 52242, United States

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2021 in Physica Medica
Verified
Journal Article
Closed access
CMCharles K. Matrosic
Charles K. Matrosic
WCWesley Culberson
Wesley Culberson
ASAndrew Shepard
Andrew Shepard
SJSydney Jupitz
Sydney Jupitz
BBBryan Bednarz
Bryan Bednarz

13 June 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SJSydney A. Jupitz
Sydney A. Jupitz
ASAndrew J. Shepard
Andrew J. Shepard
PHPatrick Hill
Patrick Hill
BBBryan P. Bednarz
Bryan P. Bednarz
Intrafraction imaging‐based motion management systems for external beam radiotherapy can rely on internal surrogate structures when the target is not easily visualized. This work evaluated the validity of using liver vessels as internal surrogates for the estimation of liver tumor motion. Vessel and tumor motion were assessed using ten two‐dimensional sagittal MR cine datasets collected on the ViewRay MRIdian. For each case, a liver tumor and at least one vessel were tracked for 175 s. A tracking approach utilizing block matching and multiple simultaneous templates was applied. Accuracy of the tracked motion was calculated from the error between the tracked centroid position and manually defined ground truth annotations. The patient’s abdomen surface and diaphragm were manually annotated in all frames. The Pearson correlation coefficient (CC) was used to compare the motion of the features and tumor in the anterior–posterior (AP) and superior–inferior (SI) directions. The distance between the centroids of the features and the tumors was calculated to assess if feature proximity affects relative correlation, and the tumor range of motion was determined. Intra‐ and interfraction motion amplitude variabilities were evaluated to further assess the relationship between tumor and feature motion. The mean CC between the motion of the vessel and the tumor were 0.85 ± 0.11 (AP) and 0.92 ± 0.04 (SI), 0.83 ± 0.11 (AP) and −0.89 ± 0.06 (SI) for the surface and tumor, and 0.80 ± 0.17 (AP) and 0.94 ± 0.03 (SI) for the diaphragm and tumor. For intrafraction analysis, the average amplitude variability was 2.47 ± 0.77 mm (AP) and 3.14 ± 1.49 mm (SI) for the vessels, 2.70 ± 1.08 mm (AP) and 3.43 ± 1.73 mm (SI) for the surface, and 2.76 ± 1.41 mm (AP) and 2.91 ± 1.38 mm (SI) for the diaphragm. No relationship between distance and motion correlation was observed. The motion of liver tumors and liver vessels was well correlated, making vessels a suitable surrogate for tumor motion in the liver.

1 July 2021 in Physica Medica
Verified
Journal Article
Closed access
BBBryan P. Bednarz
Bryan P. Bednarz
SJSydney Jupitz
Sydney Jupitz
WLWarren Lee
Warren Lee
DMDavid Mills
David Mills
HCHeather Chan
Heather Chan
TFThomas K. Foo
Thomas K. Foo