1 October 2007 in The Journal of the Acoustical Society of America
Characteristics of distortion product otoacoustic emission (DPOAE) measurements were investigated by comparing responses from two different emission measurement systems in 40 volunteers (78 ears) and making test-retest measurements of each system in 20 ears. For transformation of results between systems, it was shown that the minimum data set consisted of input-output (growth) functions obtained by stepping stimulus levels across a wide range, for each set of stimulus frequencies (1-8 kHz). Linear transformations were considered which involved either recalibration of the emission amplitude (vertical transformation) or of the stimulus levels (horizontal transformation). Horizontal transformations provided better agreement between growth functions from the two systems. For frequencies 4-8 kHz, the means of the horizontal shifts required ranged from 8 to 14 dB, clearly exceeding test-retest variability. The optimal horizontal transformation was derived and applied uniformly to all emission measurements; correlations r=0.81-0.89 were found between transformed emission amplitudes. To minimize the necessity for such transformations and to reduce the variability found both within and between systems, development of standardized equipment and methods is suggested for DPOAE measurements, including: (1) an optimized in-ear probe assembly; (2) use of intensity calibration; and (3) a focus on emission "threshold" measurement and analysis.
1 July 2021 in Physica Medica
24 June 2026 in Photoacoustics
Aiming at an intelligent point-of-care imaging technology for rheumatology clinics, a fully automatic 3D photoacoustic (PA) and ultrasound (US) dual-modality system driven by a robot and powered by deep learning (DL)-based image processing was developed. Automated scanning of volumetric images from patient joints, plus DL-based tissue segmentation and quantification of imaging biomarkers, ensures that the measurements from this system are objective and reproducible. Clinical validation was conducted via a longitudinal study on 43 finger joints from patients affected by inflammatory arthritis. Using manual segmentations as the gold standard, our DL algorithm utilizing the 3D Deep Attentive Feature (DAF3D) model showed satisfactory performance in automatic segmentation of joint space and synovial region and achieved a Dice score of 0.77±0.03 and an IoU of 0.64±0.03. Based on the tissue segmentations facilitated by the DAF3D model, six volumetric imaging biomarkers reflecting the activity of arthritis and its change in response to the treatment were quantified, including hyperemia, blood oxygenation, US power Doppler, joint space echogenicity, joint space volume, and synovial volume. The imaging biomarkers quantified from DL-based segmentation and manual segmentation showed moderate to strong correlations (: 0.41−0.86). Hyperemia quantified from PA imaging has the strongest association with the disease activity indicated by Clinical Assessment Questionnaire (CAQ) scores, with =0.41. Linear models combining the two biomarkers from PA imaging, the four biomarkers from US imaging, and all six imaging biomarkers rendered moderate to very strong associations with the disease activity scores, with of 0.41, 0.26, and 0.52, respectively.