Gabriel Regnault

Gabriel Regnault

Auto-generated profile, based on publicly available information

Gabriel Regnault

Department of Bioengineering, University of Washington, Seattle, WA, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
GRGabriel Regnault
Gabriel Regnault
CMCyril Mauger
Cyril Mauger
PBPhilippe Blanc-Benon
Philippe Blanc-Benon
ADAlexander A. Doinikov
Alexander A. Doinikov
CIClaude Inserra
Claude Inserra
In this study, we report recent theoretical and experimental developments dealing with the axisymmetric flow surrounding non-spherically oscillating microbubbles. A wide variety of microstreaming patterns is revealed using a theoretical modeling providing exact analytical solutions of the second-order mean flows. The streaming pattern is highly dependent on the modal content of the bubble interface oscillation, including possibly spherical, translational, and nonspherical modes, as well as any combination of these modes. Experimental results on fluid flow induced by a single, non-spherically oscillating bubble in an unbounded fluid are presented and successfully compared to the theoretical predictions.

28 September 2020 in Physical Review E
Verified
Journal Article
Closed access
PDF file
GRGabriel Regnault
Gabriel Regnault
CMCyril Mauger
Cyril Mauger
PBPhilippe Blanc-Benon
Philippe Blanc-Benon
CIClaude Inserra
Claude Inserra
Two acoustic bubbles may attract or repel due to the secondary radiation force acting on them. We use here a dual-frequency levitation chamber in order to trap two oscillating microbubbles at close, fixed distance, and to perform measurements of the interaction force. We successfully compare our measurements to a commonly used theoretical model that assumes linear spherical oscillations, and disregards attenuation and multiple scattering between bubbles. The deviation from the model arises when nonspherical surface oscillations are triggered, leading to an additional hydrodynamic force induced by second-order liquid flow.

1 March 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
GRGabriel Regnault
Gabriel Regnault
ADAlexander A. Doinikov
Alexander A. Doinikov
CMCyril Mauger
Cyril Mauger
PBPhilippe Blanc-Benon
Philippe Blanc-Benon
CIClaude Inserra
Claude Inserra
We investigate experimentally the attraction between two closely spaced, oscillating microbubbles. Above a certain value of the applied acoustic field, the bubbles jump to a new equilibrium location, where they are separated by a thin fluid layer whose the thickness is much smaller than the bubble radii. We demonstrate that this new equilibrium is caused by the sign reversal of the radiation interaction force acting between the two bubbles, attributed to the multiple rescattering effects of the waves emitted by the bubbles. Theoretical investigation reveals that a new stable equilibrium appears at short distances, resulting in a quasi-contacting bubble pair.

1 September 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
GRGabriel Regnault
Gabriel Regnault
MKMitchell A. Kirby
Mitchell A. Kirby
Ruikang WangRuikang Wang
Ruikang Wang
TSTueng T. Shen
Tueng T. Shen
MOMatthew O’donnell
Matthew O’donnell
IPIvan Pelivanov
Ivan Pelivanov
Corneal collagen crosslinking (CXL) is commonly used to prevent or treat keratoconus. Although changes in corneal stiffness induced by CXL surgery can be monitored with non-contact dynamic optical coherence elastography (OCE) by tracking mechanical wave propagation, depth dependent changes are still unclear if the cornea is not crosslinked through the whole depth. Here, phase-decorrelation measurements on optical coherence tomography (OCT) structural images are combined with acoustic micro-tapping (AµT) OCE to explore possible reconstruction of depth-dependent stiffness within crosslinked corneas in an ex vivo human cornea sample. Experimental OCT images are analyzed to define the penetration depth of CXL into the cornea. In a representative ex vivo human cornea sample, crosslinking depth varied from ∼100 µm in the periphery to ∼150 µm in the cornea center and exhibited a sharp in-depth transition between crosslinked and untreated areas. This information was used in an analytical two-layer guided wave propagation model to quantify the stiffness of the treated layer. We also discuss how the elastic moduli of partially CXL-treated cornea layers reflect the effective engineering stiffness of the entire cornea to properly quantify corneal deformation.

7 October 2020 in Physical Review E
Verified
Journal Article
Closed access
PDF file
CIClaude Inserra
Claude Inserra
GRGabriel Regnault
Gabriel Regnault
SCSarah Cleve
Sarah Cleve
CMCyril Mauger
Cyril Mauger
ADAlexander A. Doinikov
Alexander A. Doinikov
This paper is the conclusion of work done in our previous papers [A. A. Doinikov et al., Phys. Rev. E 100, 033104 (2019); Phys. Rev. E 100, 033105 (2019)]. The overall aim of the study is to develop a theory for modeling the velocity field of acoustic microstreaming produced by nonspherical oscillations of a gas bubble. In our previous papers, general equations were derived to describe the velocity field of acoustic microstreaming produced by modes m and n of bubble oscillations. Particular cases of mode interaction were derived, such as the 0−n, 1−1, 1−m, and n−n interactions. Here the general case of interaction between modes n and m, n>m, is solved analytically. Solutions are expressed in terms of complex mode amplitudes, meaning that the mode amplitudes are assumed to be known and serve as input data for the calculation of the velocity field of microstreaming. No restrictions are imposed on the ratio of the bubble radius to the viscous penetration depth. The n−m interaction results in specific streaming patterns: At large distance from the bubble interface the pattern exhibits 2|n−m| lobes, while 2min(m,n) lobes exist in the bubble vicinity. The spatial organization of the recirculation zones is unique for the interaction of two distinct nonspherical modes and therefore appears as a signature of the n−m interaction.

1 March 2023 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
MKMitchell A. Kirby
Mitchell A. Kirby
GRGabriel Regnault
Gabriel Regnault
IPIvan Pelivanov
Ivan Pelivanov
MOMatthew O'Donnell
Matthew O'Donnell
RWRuikang K. Wang
Ruikang K. Wang
TSTueng T. Shen
Tueng T. Shen
Purpose: The purpose of this study was to demonstrate accurate measurement of corneal elastic moduli in vivo with noncontact and noninvasive optical coherence elastography. Methods: Elastic properties (in-plane Young's modulus, E, and both in-plane, μ, and out-of-plane, G, shear moduli) of rabbit cornea were quantified in vivo using noncontact dynamic acoustic micro-tapping optical coherence elastography (AµT-OCE). The intraocular pressure (IOP)-dependence of measured mechanical properties was explored in extracted whole globes following in vivo measurement. A nearly incompressible transverse isotropic (NITI) model was used to reconstruct moduli from AµT-OCE data. Independently, cornea elastic moduli were also measured ex vivo with traditional, destructive mechanical tests (tensile extensometry and shear rheometry). Results: Our study demonstrates strong anisotropy of corneal elasticity in rabbits. The in-plane Young's modulus, computed as E = 3μ, was in the range of 20 MPa to 44 MPa, whereas the out-of-plane shear modulus was in the range of 34 kPa to 261 kPa. Both pressure-dependent ex vivo OCE and destructive mechanical tests performed on the same samples within an hour of euthanasia strongly support the results of AµT-OCE measurements. Conclusions: Noncontact AµT-OCE can noninvasively quantify cornea anisotropic elastic properties in vivo. Translational Relevance: As optical coherence tomography (OCT) is broadly accepted in ophthalmology, these results suggest the potential for rapid translation of AµT-OCE into clinical practice. In addition, AµT-OCE can likely improve diagnostic criteria of ectatic corneal diseases, leading to early diagnosis, reduced complications, customized surgical treatment, and personalized biomechanical models of the eye.