Srinivasa M. Salapaka

Srinivasa M. Salapaka

Auto-generated profile, based on publicly available information

Srinivasa M. Salapaka

Department of Mechanical Science and Engineering, University of Illinois UrbanaChampaign, Urbana, IL, USA

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
AAAlireza Askarian
Alireza Askarian
JPJaesang Park
Jaesang Park
SSSrinivasa Salapaka
Srinivasa Salapaka
This article presents an extensive framework focused on the control design, along with stability and performance analyses, of grid-following (GFL) inverters. It aims to ensure their effective operation under both stiff and weak grid conditions. The proposed framework leverages the coupled algebraic structure of the transmission line dynamics in the $dq$ frame to express and then mitigate the effect of coupled dynamics on the GFL inverter's stability and performance. In addition, we simplify the coupled multi-input multi-output (MIMO) closed-loop system of the GFL into two separate single-input single-output (2-SISO) closed loops for easier analysis and control design. We present the stability, robust stability, and performance of the original GFL MIMO closed-loop system through our proposed 2-SISO closed-loop framework. This approach simplifies both the control design and its analysis. Our framework effectively achieves grid synchronization and active damping of filter resonance via feedback control. This eliminates the need for separate phase-locked loop and virtual impedance subsystems. We also utilize the Bode sensitivity integral to define the limits of GFL closed-loop stability margin and performance. These fundamental limits reveal the necessary tradeoffs between various performance goals, including reference tracking, closed-loop bandwidth, robust synchronization, and the ability to withstand grid disturbances. Finally, we demonstrate the merits of our proposed framework through detailed simulations and experiments. These showcase its effectiveness in handling challenging scenarios, such as asymmetric grid faults, low-voltage operation, and the balance between harmonic rejection and resonance suppression.

19 May 2020 in IEEE Transactions on Control of Network Systems
Verified
Journal Article
Closed access
ASAmber Srivastava
Amber Srivastava
SSSrinivasa M. Salapaka
Srinivasa M. Salapaka
We present a framework for solving simultaneously the problems of Facility Location and Path Optimization in static and dynamic spatial networks. In the static setting, the objective is to determine facility locations and transportation paths from each node to the destination via the network of facilities such that the total cost of commodity transportation is minimized. This is an NP-hard problem. We propose a novel stage-wise viewpoint of the paths which is instrumental in designing the decision variable space in our framework. We use Maximum Entropy Principle to solve the resulting optimization problem. In the dynamic setting, nodes and the destination are dynamic. We design an appropriate control Lyapunov function to determine the time evolution of facilities and paths such that the transportation cost at each time instant is minimized. Our framework enables quantifying attributes of the facilities and transportation links in terms of the decision variables. Consequently, it becomes possible to incorporate application specific constraints on individual facilities, links, and network topology. We demonstrate the efficacy of our proposed framework through extensive simulations.

18 August 2021 in IEEE Transactions on Cybernetics
Verified
Journal Article
Closed access
ASAmber Srivastava
Amber Srivastava
SSSrinivasa M. Salapaka
Srinivasa M. Salapaka
We present a framework to address a class of sequential decision-making problems. Our framework features learning the optimal control policy with robustness to noisy data, determining the unknown state and action parameters, and performing sensitivity analysis with respect to problem parameters. We consider two broad categories of sequential decision-making problems modeled as infinite horizon Markov decision processes (MDPs) with (and without) an absorbing state. The central idea underlying our framework is to quantify exploration in terms of the Shannon entropy of the trajectories under the MDP and determine the stochastic policy that maximizes it while guaranteeing a low value of the expected cost along a trajectory. This resulting policy enhances the quality of exploration early on in the learning process, and consequently allows faster convergence rates and robust solutions even in the presence of noisy data as demonstrated in our comparisons to popular algorithms, such as $Q$ -learning, Double $Q$ -learning, and entropy regularized Soft $Q$ -learning. The framework extends to the class of parameterized MDP and RL problems, where states and actions are parameter dependent, and the objective is to determine the optimal parameters along with the corresponding optimal policy. Here, the associated cost function can possibly be nonconvex with multiple poor local minima. Simulation results applied to a 5G small cell network problem demonstrate the successful determination of communication routes and the small cell locations. We also obtain sensitivity measures to problem parameters and robustness to noisy environment data.

25 November 2013 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
YXYunwen Xu
Yunwen Xu
SSSrinivasa M. Salapaka
Srinivasa M. Salapaka
CBCarolyn L. Beck
Carolyn L. Beck
In this technical note, we consider the dynamic coverage control problem from a clustering perspective, to which we apply control-theoretic methods to identify and track the cluster center dynamics. To the authors' knowledge, this is the first work to consider tracking cluster centers when the dynamics of the system elements involve acceleration fields. We show that a dynamic control design is necessary to achieve dynamic coverage under these acceleration fields. We pose the goal of maximizing the instantaneous coverage as a combinatorial optimization problem, and propose a framework that extends the concepts of the deterministic annealing algorithm to the dynamic setting. The resulting Lagrangian is used as a control Lyapunov function for designing coverage control. The algorithms we propose guarantee asymptotic tracking of cluster group dynamics, and we further establish continuity and boundedness of the corresponding control laws. Simulations are provided to corroborate these results.

8 July 2004
Verified
Conference Paper
Closed access
SSS. Salapaka
S. Salapaka

1 March 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
SPSourav Patel
Sourav Patel
SCSoham Chakraborty
Soham Chakraborty
BLBlake Lundstrom
Blake Lundstrom
SSSrinivasa M. Salapaka
Srinivasa M. Salapaka
MSMurti Salapaka
Murti Salapaka
This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article demonstrates that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.