Umberto Startari

Umberto Startari

Auto-generated profile, based on publicly available information

Umberto Startari

Tuscany Region-National Research Council Foundation “G. Monasterio”, San Cataldo Hospital, 56124 Pisa, Italy

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Martina NestiMartina Nesti
Martina Nesti
Vincenzo RussoVincenzo Russo
Vincenzo Russo
ZPZefferino Palamà
Zefferino Palamà
LPLuca Panchetti
Luca Panchetti
SGSilvia Garibaldi
Silvia Garibaldi
Sciarra LuigiSciarra Luigi
Sciarra Luigi
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a new technology for the management of ICD patients. But what is the patients’ perspective? Previous studies on the transvenous ICD (TV-ICD) showed that device implantation is related not only to anxiety and depression because of the fear of ICD shocks, but also to many biopsychosocial factors like body image changes, perceived reduction of socialization and limitation in professional and sports activities. Anxiety and distress are more evident in younger women because of aesthetic reasons. The scar size and the position of the S-ICD can help these patients and positively influence their social relationships. Moreover, the position of the S-ICD reduces possible complications from catheters due to stress injury and can improve patients’ professional life by avoiding some work activity limitations. An S-ICD can be also a good option for athletes in avoiding subclavian crash and reducing inappropriate shocks. However, some questions remain unsolved because an S-ICD is not suitable for patients with indications for pacing, cardiac resynchronization therapy or anti-tachycardia pacing. In conclusion, the use of an S-ICD can assist physicians in reducing the negative impact of implantation on the well-being of some groups of patients by helping them to avoid depression and anxiety as well as improving their noncompliance with their medical treatment.

Verified
Journal Article
Open access
PDF file
SGSilvia Garibaldi
Silvia Garibaldi
FLFabiana Lucà
Fabiana Lucà
FCFrancesca Valeria Contini
Francesca Valeria Contini
APAlessandra Pizzuto
Alessandra Pizzuto
Gianluca MirizziGianluca Mirizzi
Gianluca Mirizzi
Giuseppe SantoroGiuseppe Santoro
Giuseppe Santoro
Background: Atrial arrhythmias represent a frequent long-term complication in patients with atrial septal defects (ASDs). Interatrial block (IAB), reflecting delayed or impaired conduction across Bachmann’s bundle, has been proposed as an electrophysiological substrate predisposing to atrial arrhythmogenesis. However, evidence regarding its prevalence and clinical correlates in pediatric patients with ASD remains limited. The present study aimed to characterize interatrial conduction patterns and assess the occurrence of IAB in children with large secundum ASD undergoing percutaneous closure. Methods: Between January 2020 and March 2024, 37 consecutive pediatric patients (median age 6 years, range 5–11) with large ostium secundum ASD were included in a retrospective analysis of a prospectively maintained institutional database. Standard 12-lead electrocardiograms were recorded before and within 24 h after defect closure. P-wave morphology and duration were systematically analyzed, and IAB was classified according to the Bayés de Luna criteria. Results: The median Qp/Qs ratio was 1.69 (1.32–2.24), with a mean pulmonary artery pressure of 19 mmHg (17–22). IAB was identified in 24.3% of patients before the procedure, predominantly as first-degree IAB. Following device implantation, IAB prevalence (29.7%) and P-wave parameters remained unchanged, with no significant differences compared with baseline. No associations were observed between IAB and defect size, hemodynamic burden, or device characteristics, whereas anthropometric variables, including weight, height, and body surface area, showed a significant correlation with IAB occurrence. During a median follow-up of 199 days, no atrial arrhythmias were documented. Conclusions: In this pediatric cohort with large ASD, IAB was present in approximately one quarter of patients and appeared unrelated to anatomical or procedural factors, supporting the hypothesis of an underlying congenital conduction abnormality. Early recognition of IAB may therefore have implications for long-term arrhythmic risk stratification in this population.