1 January 2017 in Journal of Dental Anesthesia and Pain Medicine
Kim IH, et al. J Dent Anesth Pain Med. 2017 Sep;17(3):205-213. https://doi.org/10.17245/jdapm.2017.17.3.205
1 January 2019 in Journal of Dental Anesthesia and Pain Medicine
Choi YS, et al. J Dent Anesth Pain Med. 2019 Aug;19(4):239-244. https://doi.org/10.17245/jdapm.2019.19.4.239
31 August 2025 in Journal of the Korean Association of Oral and Maxillofacial Surgeons
Kang-Hee Lee, Yong-Suk Choi, Pil-Young Yun, Ji-Young Yoon, Jeong-Kui Ku. JKAOMS 2025;51:198-204. https://doi.org/10.5125/jkaoms.2025.51.4.198
31 August 2020 in Journal of the Korean Association of Oral and Maxillofacial Surgeons
Yong-Suk Choi, Akram Abdo Almansoori, Tae-Young Jung, Jae-Il Lee, Soung Min Kim, Jong-Ho Lee. JKAOMS 2020;46:275-81. https://doi.org/10.5125/jkaoms.2020.46.4.275
30 March 2025 in Journal of Dental Implant Research
Yong-Suk Choi, Moon-Hwan Jeong, Dong-Ju Choi, Jeong-Kui Ku. Journal of Dental Implant Research 2025;44:1-7. https://doi.org/10.54527/jdir.2025.44.1.1
27 March 2026 in Journal of Oral Implantology
Use of narrow-diameter implants for single posterior molar crowns is restricted by concerns about mechanical reliability, despite their suitability for narrow ridges. To address this, we developed a wing-type narrow-diameter implant incorporating a thin cervical flange to improve biomechanical stability without increasing the implant body diameter. A three-dimensional Finite Element Analysis compared stress distribution and displacement between wing-type (3.5 mm body, 0.1–0.5 mm wings) and conventional narrow-diameter implants under various loading conditions. Additionally, eight clinical cases in seven patients with single molar restorations were analyzed over a mean 3-year follow-up, assessing implant survival, marginal bone stability, and complications. The Finite Element Analysis demonstrated that even minimal wings (0.1 mm) reduced implant settlement, while wings of 0.3–0.5 mm optimally balanced cortical and cancellous bone stress; wings ≥0.5 mm led to stress concentration in cortical bone. Clinically, all eight implants (3.5 mm diameter, ~0.35 mm wing) achieved stable osseointegration and maintained marginal bone levels with no mechanical or biological complications. All implants survived despite large mesial crown cantilevers (>40% of crown length) under high occlusal load. The wing-type design improved biomechanical performance and showed stable mid-term clinical outcomes. A 0.3–0.5 mm cervical flange is optimal, providing a minimally invasive alternative for restoring single molars in narrow ridges without bone augmentation.