1 November 2012 in Journal of Structural Engineering
This paper studies the in-plane stability of rotationally restrained shallow arches subjected to a vertical uniform load and temperature changes below 100°C. The virtual work principle method was used to establish the nonlinear equilibrium and buckling equations. Analytical solutions for the nonlinear in-plane symmetric snap-through and asymmetric bifurcation critical loads are obtained. Then the effects of the uniform temperature field and temperature gradients on the in-plane stability for arches are studied. The influence of temperature variations on the critical loads for both the symmetric snap-through and asymmetric bifurcation modes was significant. The critical loads increase with an increase of the uniform temperature field and a decrease of temperature gradients. Furthermore, the effect of temperature changes on the critical load increases with the span-rise ratio m of arches. Increasing the stiffness of the rotational springs will increase the effect of the uniform temperature field but...
1 March 2012 in Journal of Bridge Engineering
The in-plane stability of shallow parabolic arches subjected to a central concentrated load and temperature variations was investigated in this paper. The virtual work principle method was used to establish the non-linear equilibrium and buckling equations. Analytical solutions for the non-linear in-plane symmetric snap-through and antisymmetric bifurcation buckling loads were obtained. Then, the effects of temperature changes on the in-plane stability for arches with supports that stiffen under compression were studied. The results show that the influence of temperature variations on the critical loads for both buckling modes (symmetric snap-through and anti symmetric bifurcation) is significant. The critical loads for the two buckling modes are more than those only under external loads without thermal loading. Moreover, the critical loads increase with an increase of the thermal loadings. It can also be found that the effects of applying a temperature field increase when either initial stiffness coeffic...
18 July 2019 in Advances in Structural Engineering
Cross-laminated timber is a relatively new engineered timber material that can be used in the design and construction of modern timber buildings. A key factor that raises concerns in the wide application of cross-laminated timber is the uncertainty of its fire performance. This article describes experimental and numerical investigations on the fire behaviour of loaded cross-laminated timber panels manufactured with Canadian hemlock. A total of 10 cross-laminated timber panels with different number and thickness of layers were tested under ambient and standard fire conditions to investigate the flexural capacity at ambient temperature, and temperature distribution, charring rate, fire resistance, mid-span deflection under fire exposure. Three-dimensional finite element model was developed using the Hashin criterion and cohesive elements to predict the failure of wood and adhesive, respectively. The thermal model implicitly considers the rapidly increased temperature of inner fresh timber after the protective charred layers have fallen off. The numerical model was validated with the results obtained from experimental tests and was found to have the ability to simulate the fire behaviour of loaded cross-laminated timber panels in reasonable accuracy.
4 July 2012 in Journal of Zhejiang University-SCIENCE A
To investigate the fire endurance of wood beams exposed to three-side fire, we conducted bearing capacity tests of two wood beams and experiments of five wood beams exposed to three-side fire. The finite element software ANSYS was also used to predict the fire endurance of those beams with the indirect order coupling method. It was found that the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. In the case of a certain load level, the fire endurance is improved if the section size is increased or covered by the fire protection coating. The central deformation increases as the fire duration increases, and the ratio of increase tends to rise. On another note, an increase in the density of wood leads to a rise in the fire endurance of a given beam. From the finite element method (FEM) calculation results, the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. When the load level is greater than 0.5, the fire endurance is significantly reduced, and it does not change significantly when the load level changes. Lastly, for a load level magnitude below 0.5, the fire endurance and load level are proportional to one another.
1 June 2020 in Journal of Structural Engineering
The short-term flexural behavior of prestressed glulam beams reinforced with curved tendons was investigated via four-point bending of 12 glulam beams. These beams were equally divided into four groups of three identical specimens: one group of unreinforced beams, one group of prestressed beams reinforced with straight tendons, and two groups of prestressed beams reinforced with parabolic tendons. For the last two groups, the initial prestress force was applied in two levels. The results revealed that, in contrast to the failure mode of the unreinforced beams, the failure mode of the prestressed beams changed from brittle failure to ductile failure. The flexural capacity and the flexural stiffness of the prestressed glulam beams reinforced with straight tendons increased by 56.9% and 14.9%, respectively, compared with that of the unreinforced beams; for prestressed beams reinforced with parabolic tendons, the capacity and the stiffness increased by 54.4%–75.5% and 14.2%–15.5%, respectively. Based on the experimental results, a theoretical model for predicting the flexural stiffness and capacity of prestressed glulam beams was proposed. This model was validated with the test data.
28 September 2012 in JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT
This paper presents a study of a hybrid grid shell, which is made of quadrangular meshes diagonally stiffened by pre-tensioned thin cables. The construction of the hybrid structure by translating a spatial curve against another spatial curve is firstly described. Then the elasto-plastic buckling analyses of the perfect hybrid structure and the corresponding single-layer lattice shell are carried out, and the influence of the asymmetric load on the failure loads is discussed based on a finite element model. Furthermore, the different shapes and sizes of imperfections are considered in this study. Two schemes of imposing imperfections are chosen: the first several eigenvalue buckling modes and the deformed shape of the loaded structure obtained from a geometrical non-linear analysis are chosen as the imperfection shape. Finally, the effects of different structural parameters, such as the rise-to-span ratio, beam section dimension, area and pre-stress of cables and boundary conditions, on the failure loads are investigated.