Yi Liu

Yi Liu

Auto-generated profile, based on publicly available information

Yi Liu

School of Science, Harbin Institute of Technology, Weihai, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
CLChangpeng Lang
Changpeng Lang
YLYi Liu
Yi Liu
KCKunjian Cao
Kunjian Cao
SQShiliang Qu
Shiliang Qu
An optical fiber strain sensor based on capillary-taper compensation structure was proposed. The theoretical simulation by using the finite element analysis method shows a matching condition between the capillary length and the interference-cavity length to achieve the zero temperature crosstalk. Meanwhile, the strain sensitivity can also be improved greatly at the matching condition. We then set up an insertion controller system with high accuracy to make sure the interference-cavity length can match the capillary length. Finally the fiber strain sensor with both ultra-low temperature-crosstalk (0.05 pm/°C) and ultra-high sensitivity (214.35 pm/με) was achieved, and the experimental results agreed well with the calculated results. The “ladder-mode” and repeatability experiments showed that the proposed sensor was actually with the ultra-low detection limit of 0.047 µɛ.

27 August 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
HHHaoyang He
Haoyang He
YLYi Liu
Yi Liu
YLYingying Liao
Yingying Liao
CLChangpeng Lang
Changpeng Lang
YLYan Li
Yan Li
SQShiliang Qu
Shiliang Qu
A simple fiber-optic sensor for simultaneous measurement of high pressure and high temperature was proposed. The sensor was simply fabricated by splicing two sections of silica capillary tubes (SCTs) with different inner diameters to the single-mode fiber. The thick core SCT functions as a Fabry-Perot (FP) micro-cavity and an anti-resonant reflecting waveguide at the same time. The two different sensing mechanisms lead to the high contrast sensitivity values of pressure and temperature (‒3.76 nm/MPa, 27.7 pm/°C and 4.24 nm/MPa, 0.82 pm/°C). We also proposed a simple and effective method to evaluate the actual sensitivities of two-parameter sensors by using linear programming, which shows that our sensor is more sensitive than others in high pressure and high temperature simultaneous detection. Besides, low cost, good mechanical property and convenient reflective probe make the sensor more competitive in actual application.

1 July 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CLChangpeng Lang
Changpeng Lang
YLYi Liu
Yi Liu
KCKunjian Cao
Kunjian Cao
YLYan Li
Yan Li
SQShiliang Qu
Shiliang Qu

17 January 2014 in Applied Optics
Verified
Journal Article
Closed access
PDF file
YLYi Liu
Yi Liu
SQShiliang Qu
Shiliang Qu
The Fabry–Perot interferometer (FPI) cavity in a single-mode fiber with two open faces was fabricated by using the method of femtosecond laser-induced water breakdown. Then the FPI cavity was annealed by the arc discharge to greatly smooth its internal surface. The whole fabrication process features simple operation and high efficiency. The fabricated FPI cavity exhibits a perfect interferometer spectrum with reflection loss of only −3  dB and fringe visibility of almost 30 dB. It can be used as a perfectly reliable liquid refractive index sensor, as it exhibits high sensitivity (1147.48  nm/RIU), good linearity (99.93%), good repeatability, high actual measurement accuracy (1.29×10−4RIU), large measurement range, and good temperature insensitive characteristic.

3 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LHLiangtao Hou
Liangtao Hou
YLYan Li
Yan Li
YFYiming Fu
Yiming Fu
JYJiuru Yang
Jiuru Yang
WXWeijiang Xu
Weijiang Xu
LRLingling Ran
Lingling Ran
To enhance humidity sensitivity, a parallel Fabry–Perot interferometer (FPI)-based Vernier scheme is theoretically and experimentally developed via the parallel and separated micro-cavities of polyvinyl alcohol (PVA) and hollow core fiber (HCF). Through Au-film assistance and fine attenuation adjustment, the matched light energy of micro-cavities is obtained and high-contrast envelope with ~11-fold improvement is demonstrated within the 200-nm range. Centering the $\sim 77~\mu \text{m}$ length Au-PVA micro-cavity, the comprehensive tests in terms of humidity are conducted. The experimental results show that, owing to the magnification of Vernier effect, ultra-sensitive humidity response of −9.14 nm/%RH is gained. And the crosstalk of temperature is constrained within −0.0843%RH/°C. In addition, 0.505 s dynamic time-response is verified through field tests of breathing. With the merits of stability, compact size, and ease of operation, our scheme is very practical and has potential in the applications of humidity-related biochemical sensing and medical health monitoring.

20 September 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
DYDahai Yang
Dahai Yang
YLYan Li
Yan Li
DDDuo Deng
Duo Deng
JYJingfu Ye
Jingfu Ye
YLYi Liu
Yi Liu
JLJie Lin
Jie Lin
We propose a highly efficient phase modulation method for generating an elliptic optical vortex with an arbitrary controllable rotation angle, that can be recognized as a controllable degree of freedom. A transformation matrix and rotation matrix were used to realize the modulation of the light field. We numerically and experimentally demonstrate the control capability of Bessel beam and higher-order Laguerre–Gauss vortex modes. The rotation angle β , elliptic degree e and multiplexing elliptic optical vortices could be freely modulated by using the proposed method. This work is important for the progress of programmable optical tweezers, as well as for automated optical transport operations which are of interest in colloidal physics and biophysics. It can also be applied in high-dimensional and multiphoton quantum experiments.