The compressive response of hollow section, centrifugal concrete-filled GFRP tube (HS-CFGT) members is examined experimentally and reported analytically in this paper. A total of 17 specimens separated into two groups were tested; the specimens in each group were of four different lengths and included thirteen straight columns and four tapered columns. The details of the test rigs, procedures as well as key test observations composed of ultimate-moment capacities, load-displacement curves, and failure modes were truthfully reported. The test results were analyzed to evaluate the influence of initial eccentricity on the structural performance. Therefore, the aim of this paper is: (1) to propose a proper coefficient, φe, reflecting the effect of initial eccentricity based on the Chinese design code; and (2) to determine a new confinement coefficient, kcc = 1.10, for centrifugal concrete confined by GFRP tubes. Comparisons of the present design codes and specifications of confined concrete members with test results on 17 full-scale tube columns are also presented. Accordingly, new design equations, whose predictions generally agree well with the test results, are recommended to estimate the compressive capacity of the proposed HS-CFGT columns.
Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study.
Existing research on hollow section concrete-filled GFRP tube (HS-CFGT) columns has largely focused on their behavior under axial compression. However, these members are often subjected to eccentric loading in practice, which remains insufficiently understood. In particular, the coupled effects of axial force and bending, as well as the influence of geometric variation, have not been adequately addressed in current studies. To address this gap, this study presents an experimental investigation of HS-CFGT columns, including both cylindrical and tapered configurations. A series of tests was carried out at different levels of eccentricity to examine load-carrying capacity, deformation behavior, and failure characteristics. The results indicate that increasing eccentricity leads to a clear reduction in load capacity and stiffness, with failure typically initiated by crushing of the inner concrete, followed by progressive rupture of the GFRP tube. In addition, lateral deformation becomes more pronounced as eccentricity increases. It is also observed that, in the present tests, tapered members exhibited slightly higher load-carrying capacity than cylindrical members at relatively low eccentricities. This observation may suggest a beneficial effect of non-uniform geometry. Based on these observations, a design-oriented prediction formulation is proposed by incorporating the interaction between axial force and bending moment. The proposed model provides a practical and reliable tool for evaluating HS-CFGT members and supports their safe application in structural systems where eccentric loading cannot be avoided.