El?in Sagırkaya, DDS, PhD/Ahmet Serkan Kucukekenci, DDS/Durdu Karasoy, MSc, PhD/Kıvan? Ak?a, DDS, PhD/Steven Eckert, DDS, MS/Murat Cavit ?ehreli, DDS, PhD: Purpose: To evaluate factors that have an influence on histomorphometric bone-to-implant contact (BIC) of dental implants in humans. Materials and Methods: Using inclusion/exclusion criteria, eligible studies were searched in five databases and handsearched in 11 journals. A total of 351 articles were assigned to full text analysis. The extracted data were assigned to comparative statistical assessments and meta-analysis. Results: A total of 55 articles were included in the analysis. The mean BIC found in comparative assessments and meta-analysis of implants in the mandible (70.97 and 69.744 ? 3.304, respectively) was higher than those in the maxilla (53.24 and 56.692 ? 3.598; P = .000 and P = .008, respectively). The mean BIC in the anterior mandible (79.42) and maxilla (74.19) were higher than the posterior mandible (69.14) and maxilla (36.68) (P < .05). Differences were detected in BIC of commercially available implants and experimental micro-implants (P < .05). Comparative assessments and meta-analysis showed that conventionally loaded implants (75.70 and 75.786 ? 4.889, respectively) had higher BIC than unloaded (54.07 and 53.24 ? 4.971, respectively) and immediately loaded implants (58.53 and 68.831 ? 4.972; P = .000 and P = .004, respectively). Conclusions: Based upon a meta-analysis of the literature the following conclusions can be made: The BIC in the mandible is higher than the maxilla. The BIC is higher in the anterior than the posterior regions. The implant design coupled with the anatomical region affects the amount of BIC. Placement of experimental micro-implants with different surfaces in the posterior region always result in low and almost comparable BIC. The loading state and healing period seems to have an influence on BIC. Specific reporting guidelines are required to improve reporting of studies on human BIC.
Background: This study aimed to evaluate the impact of various surface treatments on the shear bond strength (SBS) of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) polymers to indirect laboratory composite (ILC) and lithium disilicate ceramic (LDC) veneering materials. Methods: Polymer specimens (7 × 7x2 mm) were sectioned from PEEK and PEKK discs (N = 294) and randomly allocated to 7 groups (n = 20); untreated (Cnt), plasma (Pls), 98% sulfuric acid (Sa), sandblasting with 110 µm Al2O3 (Sb), tribochemical silica coating with 110 µm silica modified Al2O3 (Tbc), Sb + Sa, Tbc + Sa. Scanning electron microscopy assessments were performed on one sample of each treatment group, and veneering materials were applied to the remaining specimens (n = 10). The specimens were subjected to the SBS test after being soaked in distilled water (24 h, 37 °C). Three-way ANOVA, independent sample t-test, and Tukey HSD test were performed for statistical analyses (α = .05). Results: The surface treatment, polymer, veneering material types, and their interactions were significant on SBS results according to the 3-way ANOVA (p < 0.001). The SBS values of ILC veneered groups were significantly higher than LDC groups, regardless of surface treatment and polymer type (p < 0.05). The highest SBS values were obtained for Sa-applied ILC veneered PEEK (21.55 ± 1.45 MPa) and PEKK (17.04 ± 1.99 MPa) polymer groups (p < 0.05). Conclusion: The effect of surface treatment and veneering materials may be significant on the SBS values of PAEKs. Therefore, the application parameters of surface treatments should be more specified for the applied veneering material and polymer type.
Several additively and subtractively manufactured resin-based materials indicated for interim and definitive fixed dental prostheses have been launched. However, knowledge of the bond strength of these materials to different implant abutment materials is limited. The purpose of this in vitro study was to evaluate the shear bond strength (SBS) of additively and subtractively manufactured resin-based materials to different implant abutment materials. One hundred and ten disk-shaped specimens (Ø3×3 mm) were fabricated either additively from 2 resins indicated for definitive use (Crowntec; AM_CT and VarseoSmile Crown Plus; AM_VS) and 1 resin indicated for interim use (FREEPRINT temp; AM_FP) or subtractively from a nanographene-reinforced polymethyl methacrylate (G-CAM; SM_GC) and a high-impact polymer composite (breCAM.HIPC; SM_BC). After allocating 2 specimens from each group for scanning electron microscope evaluation, the specimens were divided according to the abutment material (CopraPeek; polyetheretherketone, PEEK and Dentium Superline Pre-Milled Abutment; titanium, Ti) (n=10). All specimens were airborne-particle abraded with 50-µm aluminum oxide. After applying a resin primer (Visio.link) to PEEK and an adhesive primer (Clearfil Ceramic Primer Plus) to Ti specimens, a self-adhesive resin cement (PANAVIA SA Cement Universal) was used for cementation. All specimens were stored in distilled water (24 hours, 37 °C), and a universal testing device was used for the SBS test. SBS data were analyzed with 2-way analysis of variance and Tukey honestly significant difference tests, while the chi-squared test was used to evaluate the difference among the abutment-resin pairs in terms of failure modes (α=.05). The interaction between the material type and the abutment type and the main factor of material type affected the SBS (P<.001). SM_BC-PEEK and SM_GC had the lowest SBS followed by SM_BC-Ti, whereas AM_VS-PEEK had the highest SBS (P≤.001). AM_CT-Ti had higher SBS than AM_FP-PEEK (P=.026). SM_GC had the lowest and AM_VS had the highest SBS, while AM_CT and AM_FP had higher SBS than SM_BC (P≤.004). The distribution of failure modes was significantly different among tested material-abutment pairs, and only for AM_CT among tested materials (P≤.025). Most of the material-abutment pairs had a minimum of 80% adhesive failures. Regardless of the abutment material, additively manufactured specimens had higher bond strength and one of the subtractively manufactured materials (SM_GC) mostly had lower bond strength. The abutment material had a small effect on the bond strength. Adhesive failures were observed most frequently.
The surface properties and color stability of interim crown materials may vary depending on the toothbrushing procedure. This study aimed to investigate the effects of toothbrushing and different toothpastes on the surface roughness (Ra) and color stability of different interim crown materials. Disc-shaped specimens were prepared from four interim crown materials (Tab 2000 (ChPM), Imident (LaPM), Protemp 4 (ChDM), and Telio-CAD (CadPM)). Specimens were divided into four subgroups for the control group (Cnt) and for simulated toothbrushing with distilled water (Dw) or with two different toothpastes (whitening toothpaste (WTp), activated charcoal toothpaste (ACTp)). The specimens’ Ra values were measured before and after 10,000 cycles of toothbrushing. The color parameters were measured and the color differences (ΔE00) were calculated. Data were statistically analyzed by two-way analysis of variance (ANOVA) and Tukey’s HSD tests. A significant increase in the Ra values was observed after toothbrushing, except for the LaPM_Dw, ChDM_Dw, and all the CadPM specimens (p < 0.05). Toothbrushing with toothpastes increased the ΔE00 values of all ChPM and ChDM interim materials (p < 0.05). Before and after all toothbrushing procedures, the CadPM specimens had smoother and ChPM specimens had rougher surfaces than the other interim materials. The two tested toothpastes had similar effects on the Ra of all interim materials. Non-perceivable color changes were seen only with the CadPM_Dw group.
1 July 2019 in The Journal of Prosthetic Dentistry