Abdurrahman Karabulut

Abdurrahman Karabulut

Auto-generated profile, based on publicly available information

Abdurrahman Karabulut

Afyon Kocatepe Universitesi

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
ÖVÖzgür VERİM
Özgür VERİM
MYM. Volkan Yaprakci
M. Volkan Yaprakci
AKAbdurrahman Karabulut
Abdurrahman Karabulut

3 October 2022 in International Journal of Automotive Science And Technology
Verified
Journal Article
Closed access
PDF file
AKAbdurrahman Karabulut
Abdurrahman Karabulut
HŞHakan Şahman
Hakan Şahman
BKBahri Şamil Korkmaz
Bahri Şamil Korkmaz
In this study, it is aimed to reduce the vibration transmitted to the chassis by using vibration dampers in the connection between the vehicle engine and chassis. A theoretical and experimental study was examined. The vibration damper is an elastic material. In the structure of this material, spring and damping are combined with the suspension system. In this study, insulation ratios between the two were compared using new and old dampers. As the engine speed changes in the vehicles, the vibration size it produces also changes. This causes severe discomfort to the driver and passengers in the vehicle. It was observed that the vibration magnitude passing from the engine to the chassis decreased by 50%. When the old and new dampers are compared, it is seen that the vibration isolation of old dampers is very weak. Therefore, it was concluded that the appropriate damper should be selected according to the mass and operating conditions of the engine. Also, it was observed that vibration amplitude increases at low engine speeds, and vibration amplitude decreases at high engine speeds. It has been found that the new vibration damper is a better insulating material than the worn damper.

3 October 2022 in International Journal of Automotive Science And Technology
Verified
Journal Article
Closed access
PDF file
BKBahri Şamil Korkmaz
Bahri Şamil Korkmaz
AKAbdurrahman Karabulut
Abdurrahman Karabulut
In this study, a connecting rod that belongs to a diesel test engine is examined with an experimental method and the Finite Element Method (FEM). The purpose of the experimental method is to obtain the Frequency Response Function. The graph of this function provides the necessary vibrational qualifications of the connecting rod. Obtained vibrational characteristics can be considered as natural frequencies, damping ratios and mode shapes that belong to these vibrational modes. While natural frequencies can be obtained with both of these methods, mode shapes could only be produced with FEM. The natural frequencies that are obtained with experimental method is determined for the first mode as 0,625 Hz, for the second mode as 4,38 Hz, and for the third mode as 8,13 Hz. The natural frequencies that are obtained with FEM is determined for the first mode as 0,04575 Hz, for the second mode as 8,3861 Hz, and for the third mode as 8,9434 Hz. Considering the frequency range of the connecting rod, this study shows that the natural frequency values which is determined from this study and any frequency value of the connecting rod while the engine is running would not coincide. Besides damping ratios are calculated for the first mode as 19,766 %, for the second mode as 8,0116 %, and for the third mode as 3,4839 %. It is determined which modes have bending and torsion mode shapes. The results provide the useful information about the weaknesses and the vibrational qualifications that has to be improved in terms of dynamical and structural analysis of the connecting rod or engine itself.

1 June 2025 in Konya Journal of Engineering Sciences
Verified
Journal Article
Open access
PDF file
AKAhmet Köken
Ahmet Köken
AKAbdurrahman Karabulut
Abdurrahman Karabulut
This study provides a comprehensive analysis of the dynamic behavior, modeling, simulation, and experimental validation of industrial C-type eccentric presses, offering critical insights into the optimization of press ground vibration. Through detailed modeling, the forces and vibrations experienced during operation were mathematically characterized, while simulations effectively demonstrated the system's behavior under varying operational conditions, and experimental studies confirmed the reliability of these models. The investigation also examined the impact of dynamic loads on machine foundations, analyzing single and double mass-spring systems using MATLAB simulations and analytical solutions to assess the influence of ground-foundation characteristics on the press's dynamic response. Prior to vibration isolation, the average peak ground displacement (PGD) was measured at 5.075 × 10⁻² mm, which decreased to 3.46 × 10⁻² mm and 2.7 × 10⁻² mm with the application of VI-1 and VI-3 isolators, respectively. The VI-3 isolator proved most effective, reducing transmitted dynamic forces to 2.57 × 104 N. Parametric analyses highlighted the system's sensitivity to isolator stiffness and damping ratios, with a stiffness ratio of 0.01 between the isolator and ground reducing foundation vibrations by approximately 46.8%. This research emphasizes the importance of dynamic modeling in designing and optimizing vibration isolation systems, making a significant contribution to enhancing vibration control in industrial applications.

1 January 2025 in Afyon Kocatepe University Journal of Sciences and Engineering
Verified
Journal Article
Open access
PDF file
ASAhmet Mete Sabah
Ahmet Mete Sabah
AKAbdurrahman Karabulut
Abdurrahman Karabulut
Ağır vasıtaların karıştığı trafik kazalarında, küçük araçların ağır vasıtaların altına girme riskini azaltmak amacıyla kullanılan Arka Alt Koruma Sistemi (RUPD), çarpma anında koruma sağlayarak ciddi yaralanma ve ölümleri azaltır. Bu çalışmada, S700 MC çelik malzemesi kullanılarak yeni bir RUPD tasarımı geliştirilmiş ve ECE R58-03 yönetmeliğine uygun olarak performansı değerlendirilmiştir. Tasarım sürecinde, bilgisayar destekli tasarım (CAD) modeli oluşturulmuş ve sonlu eleman analizleri (FEA) gerçekleştirilmiştir. Yapının doğru bir şekilde yüklenmesini sağlamak için belirli noktalardan kuvvetler uygulanmış ve analiz sonuçlarına göre, toplam deformasyon değerlerinin 100 mm sınırının altında kaldığı ve tüm gerilme değerlerinin S700 MC çeliğinin akma dayanımının altında olduğu tespit edilmiştir. Sonuçlar, yeni tasarımın yönetmelik gerekliliklerini karşıladığını ve güvenli bir yapısal performans sergilediğini göstermektedir. Ayrıca, literatürde yapılan dinamik analizlerin yerine, bu çalışmada statik analizler kullanılarak optimizasyon çalışmaları yapılmış ve kaynaklı bağlantıların kullanıldığı tasarımın daha sağlam ve güvenilir olduğu belirlenmiştir. Gelecek çalışmalarda dinamik analizlerin eklenmesiyle daha kapsamlı değerlendirmeler yapılabilir.

19 June 2025 in Journal of Materials and Mechatronics: A
Verified
Journal Article
Open access
PDF file
AKAhmet Köken
Ahmet Köken
SÜSultan Seda Ülger
Sultan Seda Ülger
AKAbdurrahman Karabulut
Abdurrahman Karabulut
Bu çalışma, rulman sağlığının değerlendirilmesinde ve hasar tespitinde titreşim spektrum analizleri ve ivme ölçümlerinin etkinliğini araştırmaktadır. Deneysel analizler, sağlam (A1 ve B1) ve iç bileziği hasarlı (A2 ve B2) rulmanlar üzerinde gerçekleştirilmiştir. Sağlam rulmanların titreşim spektrumlarında düşük genlikli ve belirgin olmayan pikler gözlemlenirken, hasarlı rulmanlarda karakteristik frekanslarda yüksek genlikli pikler ve ivme ölçümlerinde önemli hata sapmaları tespit edilmiştir. A2 rulmanında 15,4 Hz, 27 Hz, 48,2 Hz ve 136,9 Hz frekanslarında belirgin pikler gözlemlenmiştir. B2 rulmanında ise 80 Hz ve 160 Hz frekanslarındaki ivme ölçümleri, rulman hasarının neden olduğu önemli sapmaları ortaya koymuştur. Elde edilen bulgular, titreşim analizinin rulman arızalarının erken teşhisi için güvenilir bir yöntem olduğunu ve düzenli bakımın rulman ömrünü uzatabileceğini göstermektedir.