18 September 2025 in IEEE Transactions on Instrumentation and Measurement
Chronic obstructive pulmonary disease (COPD) is one of the common respiratory diseases that can cause death if not intervened in time. Popular lung sound sensing-based COPD detection techniques mostly employ deep learning techniques, which suffer from the disadvantages of purely data-driven models, like low robustness against data variability across diversified datasets. This article introduces a finger photoplethysmography (PPG)-based COPD detection technique using a low-complexity, simple rule-based classifier. The primary feature extraction was done using dynamic mode decomposition (DMD), which requires low memory. A novel respiration signal predictor (RSP) based on bidirectional reservoir computing (B-RC) model is proposed to identify respiration indicative DMD mode. Evaluation was done with a total of 4970 PPG frames, each of size 2750 samples collected from three public datasets and volunteers, resulting in 95.13% accuracy and 100% sensitivity of the RSP. Detection accuracy and sensitivity of acute COPD, moderate COPD, healthy subjects, and artificially obstructed breathing (AOB) class (a synthetic one derived from healthy subjects) were 99.7% and 99.5%, respectively. The average latency and peak memory requirement on single-core ARM v6 controller (512-MB RAM and 1-GHz frequency) were 616 ms and 458.44 kB, respectively, to process one PPG frame. The present method can be utilized for quick screening of COPD as a point-of-care (POC) technology.
10 October 2025 in Measurement Science and Technology
The presence of motion artifact in the photoplethysmogram (PPG) signal makes it challenging for PPG-derived respiration (PDR) measurements in continuous health monitoring. In this work, a deep-learning framework for quality-aware PDR signal extraction, named QaPRExt, is described. This includes three key stages: pre-processing of the raw PPG signal, PPG snippet quality evaluation using a reservoir computing model, namely RCSQNet, and finally, PDR extraction using the proposed QaRExt module. QaPRExt was evaluated with a synthetic noisy signal using two noise insertion strategies, viz., additive and convolution, and the real-time noisy PPG signals with their corresponding reference respiration signals collected in the laboratory. The proposed framework achieves an average correlation of 0.91, 0.88 for PDR extraction and an average mean absolute error of 0.70, 0.10 breaths per minute, respectively, in estimating respiration rate from the noisy PPG segments for the 53 subjects of BIDMC and 30 subjects from the volunteers’ database, respectively.