1 January 2019 in Construction and Building Materials
4 March 2021 in SN Applied Sciences
The reuse of waste materials in civil engineering projects has become the topic for many researchers due to their economic and environmental benefits. In this study, brick dust waste (BDW) derived from cutting of masonry bricks and demolition waste which are normally dumped as land fill is used as partial replacement of cement in a concrete mix at 10%, 20% and 30% respectively, with the aim of achieving high strength in concrete using less cement due to the environmental problems associated with the cement production. To ascertain the effects of BDW on the consistency and mechanical performance of concrete mix, laboratory investigations on the workability of fresh concrete and the strength of hardened concrete were carried out. Slump and compaction index test were carried out on fresh concrete mix and unconfined compressive strength (UCS) test and tensile strength test were conducted on hardened concrete specimen after 7, 14 and 28 days of curing. The results showed high UCS and tensile strength with the addition of 10% BDW to the concrete mix, hence achieving the set target in accordance with the relevant British standards. A gradual reduction in strength was observed as BDW content increases, however, recording good workability as slump and compaction index results fell within the set target range in accordance with relevant British standards. Findings from this study concluded that BDW can partially replace cement in a concrete mix to up to 30% igniting the path to a cleaner production of novel concrete using BDW in construction work.
29 March 2014 in Materials and Structures
1 January 2019 in Latin American Journal of Solids and Structures
This report presents a computational research on Eurocode 2 (EC2) tension lap lengths (lo) design in a normally reinforced concrete beam, using ANSYS Workbench simulation software program by simulating a laboratory 4-point beam loading test system under static loading(discrete model approach). A typical 4-point laboratory setup loading system was modelled using an innovative and sustainable Finite Element Analysis (FEA) approach. In order to investigate the EC2 tension lap lengths (lo) design recommendation, a total of 100 analysis cases of lap lengths were considered for different reinforcement bar diameters of 10mm, 12mm, 16mm, 20mm and 25mm. The study has considered beam failure types, effects of failure load on the various lap length reduction cases and effects of steel reinforcement bar size changes on the design lap lengths. The analysis of results revealed that the yield strength of steel (fyk), diameter of tension reinforcement bar, (db), tensile strength of concrete (fctd) and concrete cover (cd) are the main parameters for a tension lap length design according to EC2. While a linear relationship exists between tension steel reinforcement bar sizes (db) and the obtained lap lengths (lo). The study reveals a potential use of 15% and 20% reduction in lap length (lo) for tension steel reinforcement bar sizes of 10mm, 16mm and 12mm and 20mm in comparison with the recommended design lap length of EC2. It was concluded that EC2 tension lap length design recommendation is conservative.
9 November 2021 in Structural Concrete